ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Britton, L. W.
Right arrow Articles by Foster, E. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Britton, L. W.
Right arrow Articles by Foster, E. D.

Ann Thorac Surg 1987;43:568-569
© 1987 The Society of Thoracic Surgeons


Articles

Replacement of a Degenerated Porcine Valve Within a Composite Aortic Valve Graft

Lewis W. Britton, M.D., Eric D. Foster, M.D.*

From the Division of Cardiothoratic Surgery, Albany Medical College, Albany, NY

* Address reprint requests to Dr. Foster, Suite ME 622, Albany Medical College, Albany, NY 12208


    Abstract
 Top
 Abstract
 Footnotes
 References
 
A simple technique for replacing a valve prosthesis within a composite aortic root graft is described. This method allows isolated valve replacement without removing the Dacron tube graft or altering the original coronary artery repair.


    Footnotes
 Top
 Abstract
 Footnotes
 References
 
Presented in part at the Twenty-second Annual Meeting of the Society of Thoracic Surgeons, Washington, DC, January 27–29, 1986


    References
 Top
 Abstract
 Footnotes
 References
 

  1. Wheat Jr MW, Wilson JR, Bartley TD. Successful replacement of the entire ascending aorta and aortic valve JAMA 1964;188:717.[Medline]
  2. Singh MP, Bentall HH. Complete replacement of the ascending aorta and the aortic valve for the treatment of aortic aneurysm J Thorac Cardiovasc Surg 1972;63:218.[Medline]
  3. Bentall HH, DeBono A. A technique for complete replacement of the ascending aorta Thorax 1968;23:388.
  4. Magilligan Jr DJ, Lewis Jr JW, Jara FM, et al. Spontaneous degeneration of porcine bioprosthetic valves Ann Thorac Surg 1980;30:259.[Abstract/Free Full Text]
  5. McClung JA, Stein JH, Ambrose JA, et al. Prosthetic heart valves: a review Prog Cardiovasc Dis 1983;26:237.[Medline]
  6. In: Morse D, Steiner RM, Ferandey J, editors. Guide to Prosthetic Cardiac Valves. New York: Springer-Verlag; 1985.



This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
H. J. Safi, D. C. Iliopoulos, and D. S. Duff
Repeat replacement of aortic valve bioprosthesis
Ann. Thorac. Surg., May 1, 1995; 59(5): 1217 - 1219.
[Abstract] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Britton, L. W.
Right arrow Articles by Foster, E. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Britton, L. W.
Right arrow Articles by Foster, E. D.