ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Moran, J. M.
Right arrow Articles by Michaelis, L. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moran, J. M.
Right arrow Articles by Michaelis, L. L.

Ann Thorac Surg 1984;38:254-259
© 1984 The Society of Thoracic Surgeons


Articles

Pulmonary Artery Balloon Counterpulsation for Right Ventricular Failure: II. Clinical Experience

John M. Moran, M.D.*, Milos Opravil, M.D., Andrew J. Gorman, Ph.D., Hassan Rastegar, M.D., Sheridan N. Meyers, M.D., Lawrence L. Michaelis, M.D.

Department of Surgery, Cardiothoracic Division, and Department of Medicine, Section of Cardiology, Northwestern University, Chicago, IL

Accepted for publication December 12, 1983.

* Address reprint requests to Dr. Moran, Division of Cardiothoracic Surgery, Brown University, 110 Lockwood St, Providence, RI 02903


    Abstract
 Top
 Abstract
 References
 
The use of pulmonary artery balloon counterpulsation (PABC) provided immediate salvage following cardiac surgical procedures in 2 patients with biventricular failure in whom inotropic drugs and intraaortic balloon counterpulsation did not provide sufficient support to allow weaning from cardiopulmonary bypass. Although both patients eventually died, the hemodynamic effectiveness of PABC was documented. The various clinical settings for right ventricular as well as biventricular failure are reviewed, the currently available options for treatment are summarized, and the directions for future laboratory investigation and possible clinical applications are presented.


    References
 Top
 Abstract
 References
 

  1. Flege Jr JB, Wright CB, Reisinger TJ. Successful balloon counterpulsation for right ventricular failure Ann Thorac Surg 1984;37:167.[Abstract/Free Full Text]
  2. Miller DC, Moreno-Cabral RJ, Stinson EB, et al. Pulmonary artery balloon counterpulsation for acute right ventricular failure J Thorac Cardiovasc Surg 1980;80:760.[Abstract]
  3. Taylor RR, Covel JW, Sonnenblick EH, et al. Dependence of ventricular distensibility on filling of the opposite ventricle Am J Physiol 1967;213:711.[Free Full Text]
  4. Kelly DT, Spotnitz HM, Beiser GD, et al. Effects of chronic right ventricular volume and pressure loading on left ventricular performance Circulation 1971;44:403.[Abstract/Free Full Text]
  5. Weiss JL, Brinker JA, Lappe DL, et al. Leftward displacement during right ventricular loading in man: demonstration by two dimensional echo (abstract) Am J Cardiol 1978;41:362.
  6. Ludbrook PA, Bryne JD, McKnight RB. Influence of right ventricular hemodynamics on left ventricular diastolic pressure-volume relations in man Circulation 1979;59:21.[Abstract/Free Full Text]
  7. Bemis CE, Serur JR, Borkenhagen D, et al. Influence of right ventricular filling pressure on left ventricular pressure and dimension Circ Res 1974;34:498.[Abstract/Free Full Text]
  8. Ross Jr J. Acute displacement of the diastolic pressure volume curve of the left ventricle: role of the pericardium and the right ventricle (editorial) Circulation 1979;29:32.
  9. Pierce WS, Parr GVS, Myers JL, et al. Clinical effectiveness of mechanical ventricular bypass in treating postoperative heart failure Artif Organs 1983;7:25.[Medline]
  10. Lefemine AA. Low flow right atrial and left ventricular assist device without an oxygenator for cardiogenic shock: a revised conceptIn: Unger F, editor. Assisted Circulation. Berlin: Springer-Verlag; 1979.
  11. Parr GVS, Pierce WS, Rosenberg G, et al. Right ventricular failure after repair of left ventricular aneurysm J Thorac Cardiovasc Surg 1980;80:79.[Medline]
  12. Robinson WJ, Daly BDT, Hughes DA, et al. An abdominal left ventricular assist device: preclinical studies Ann Thorac Surg 1975;19:540.[Abstract/Free Full Text]
  13. Dotter CT, Steinberg I. The angiocardiographic measurement of the normal great vessels Radiology 1949;52:353.[Abstract/Free Full Text]



This article has been cited by other articles:


Home page
Card Surg AdultHome page
E. C. McGee Jr., P. M. McCarthy, and N. Moazami
Temporary Mechanical Circulatory Support
, January 1, 2008; 3(2008): 507 - 534.
[Full Text]


Home page
Card Surg AdultHome page
N. Moazami and P. M. McCarthy
Temporary Circulatory Support
, January 1, 2003; 2(2003): 495 - 520.
[Full Text]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. H. Danton, J. G. Byrne, K. Q. Flores, M. Hsin, J. S. Martin, R. G. Laurence, L. H. Cohn, and L. Aklog
Modified Glenn connection for acutely ischemic right ventricular failure reverses secondary left ventricular dysfunction
J. Thorac. Cardiovasc. Surg., July 1, 2001; 122(1): 80 - 91.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
A. Y. Schure, P. C. Laussen, and F. X. McGowan JR
Mechanical Cardiopulmonary Support of Infants and Children With Congenital Heart Disease
Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 2001; 5(1): 46 - 54.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. V. Letsou, K. L. Franco, W. Detmer, S. Condos, S. Wolvek, G. J. Walker Smith, and J. C. Baldwin
Pulmonary artery balloon counterpulsation: Safe after peripheral placement
Ann. Thorac. Surg., March 1, 1993; 55(3): 741 - 746.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Y. Karagoz, O. Tasdemir, C. Yakut, and K. Bayazit
Atrial Septal Defect for Right Ventricular Failure
Ann. Thorac. Surg., March 1, 1988; 45(3): 350 - 351.
[PDF]


Home page
Ann. Thorac. Surg.Home page
J. M. Caralps, J. M. Padro, M. L. Camara, A. Aris, and O. Bonnin
Creation of an Atrial Septal Defect for Acute Postperfusion Right Ventricular Failure
Ann. Thorac. Surg., April 1, 1987; 43(4): 435 - 436.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. A. Spence, C. M. Peniston, N. Mihic, A. K. Jabr, and T. A. Salerno
A Rational Approach to the Selection of an Assist Device for the Failing Right Ventricle
Ann. Thorac. Surg., June 1, 1986; 41(6): 606 - 608.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Opravil, A. J. Gorman, T. C. Krejcie, L. L. Michaelis, and J. M. Moran
Pulmonary Artery Balloon Counterpulsation for Right Ventricular Failure: I. Experimental Results
Ann. Thorac. Surg., September 1, 1984; 38(3): 242 - 253.
[Abstract] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Moran, J. M.
Right arrow Articles by Michaelis, L. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Moran, J. M.
Right arrow Articles by Michaelis, L. L.