Ann Thorac Surg 2009;87:933-934. doi:10.1016/j.athoracsur.2008.07.038
© 2009 The Society of Thoracic Surgeons
Case Reports
Giant Coronary Artery Aneurysm Associated with Medial Mucoid Degeneration
Tadahisa Sugiura, MD*,
Satoshi Saito, MD,
Shinichiro Kihara, MD,
Wataru Sato, MD,
Hiromi Kurosawa, MD
Department of Cardiovascular Surgery, The Heart Institute of Japan, Tokyo Women's Medical University, Shinjuku, Tokyo, Japan
Accepted for publication July 9, 2008.
* Address correspondence to Dr Sugiura, Department of Cardiovascular Surgery, The Heart Institute of Japan, Tokyo Women's Medical University, 8-1 Kawada, Shinjuku, Tokyo, 162-8666, Japan (Email: ssugiura{at}hij.twmu.ac.jp).
 |
Abstract
|
|---|
A 52-year-old man underwent surgical repair for coronary arteriovenous fistula including patch closure of two exitus of the fistula, double ligation of the dilated right coronary artery, and coronary bypass grafting to the right coronary artery with saphenous vein graft at the age of 25. Then, twenty-seven years later, a multi-detector computed tomographic scan revealed an aneurysmally dilated right coronary artery (4.8 cm), fistula, and saphenous vein graft. The aneurysm was resected and histologically mucoid degeneration in the media of the aneurysmal wall was detected.
 |
Introduction
|
|---|
Coronary artery aneurysm is uncommon. Its cause is mainly atherosclerotic.
A 52-year-old man was first pointed out to have a heart murmur at the approximate age of 20, but he did not consult the doctor. He contracted bacterial endocarditis, which was cured with antibiotics at age 23. Cardiac catheterization was performed the next year to reveal a coronary arteriovenous fistula that originated from the right coronary artery (RCA) and drained into the right atrium; its left-to-right shunt ratio was 56%. A surgical repair was performed at our institute in the same year. Closure of two exitus of the fistula within the RA, double ligation of the aneurysmally dilated RCA (2 cm), and aortocoronary bypass grafting with a saphenous vein graft (SVG) were performed. A follow-up catheterization at the age of 40 revealed a recurrence of arteriovenous fistula at the RCA, an RCA aneurysm with a diameter of 1.5 cm, and grade II aortic regurgitation, but we had not operated because the SVG was patent and the left-to-right shunt ratio was not significant (ie, the shunt ratio was 30%). Twelve years later, the patient was admitted to our hospital for an operation at the age of 52, because a multi-detector computed tomographic scan revealed an aneurysmally dilated RCA with a diameter of 4.8 cm.
The chest roentgenogram was normal and electrocardiographic measurements showed no ST segment change. Cardiac catheterization showed an aneurysmally dilated RCA after a dilated fistula and a dilated SVG. The pulmonary-to-systemic blood flow ratio was 1.47, the ejection fraction was 52%, and grade II aortic regurgitation was detected. It was revealed that the SVG was patent, but there was 75% stenosis just distal to the anastomosis. Transesophageal echocardiography revealed two shunt flows from distal to the fistula into the RA. A multi-detector computed tomographic scan showed an aneurysmally dilated RCA with a diameter of 4.8 cm after a dilated exitus of the fistula into the right atrium, and a dilated SVG (Fig 1).

View larger version (134K):
[in this window]
[in a new window]
|
Fig 1. Multi-detector computed tomographic image shows aneurysmally dilated right coronary artery, fistula, and saphenous vein graft. (RCA = right coronary artery; SVG = saphenous vein graft.)
|
|
Under the preparation of femoro-femoral bypass, a median sternotomy was performed. After harvesting the radial artery graft, cardiopulmonary bypass was established with ascending aortic perfusion and bi-caval drainage. The RA was incised and two bleeding points were detected near the previous exitus of the fistula, which had been closed 27 years before. They were directly closed with 4-0 polypropylene. An aortotomy was performed, and two holes with a diameter of 8 mm were detected in the right coronary cusp. It was presumably attributable to infective endocarditis. Aortic valve replacement was performed with a St. Jude Medical mechanical heart valve (23 mm). The radial artery graft was anastomosed to the middle portion of the RCA. An aneurysmally dilated RCA and SVG were resected together and were closed with a continuous suture. The defect of the aortic wall, including the ostium of the RCA and SVG was closed with a Xenomedica patch (Baxter Healthcare, Chicago, IL).
Pathohistologic examination revealed mucoid degeneration in the media of the aneurysmal wall (Fig 2). The multi-detector computed tomographic scan after the operation showed the radial artery graft was patent and the RCA had a good run off.

View larger version (114K):
[in this window]
[in a new window]
|
Fig 2. Microscopical observation of the media of the right coronary artery. Eosin-stained areas are mucoid degeneration. (Hematoxylin and eosin stain, original magnification x100.)
|
|
 |
Comment
|
|---|
The incidence of coronary artery aneurysm is reported to be 4.9% based on the Coronary Artery Surgery Study (CASS) registry [1]. Atherosclerosis is the most common cause of coronary artery aneurysm [2]. It can occur secondary to inflammatory or infectious disease (ie, Kawasaki disease, Takayasu disease, systemic lupus erythematosus, or polyarteritis nodosa, endocarditis, and syphilis), connective tissue disease (ie, Marfan's syndrome, Ehlers-Danlos syndrome), metastatic tumors, or blunt trauma [3]. In this case, the patient did not suffer from systemic connective tissue disease. Histologically mucoid degeneration of the RCA and SVG is believed to be a cause of aneurysmal dilatation.
Bacterial endocarditis develops in patients with coronary artery fistula [4]. Bacterial endocarditis was believed to be a complication of coronary artery fistula in this patient. The combination of coronary artery aneurysm with arteriovenous fistula is rarer (0.2%) [5]. The case of coronary artery aneurysm of the RCA with arteriovenous fistula resulting from high blood flow from a high-pressure chamber to a low-pressure chamber was previously reported [6]. Residual or recurrent fistulas were found in 4 of 41 patients (9.8%) who underwent coronary artery fistula operations. The incidence of recurrence was higher in the external plication or division of fistula group compared with the intracardiac closure group [7]. In this case, mucoid degeneration of the aneurysmal wall, as well as high blood flow resulted in giant coronary artery aneurysm.
 |
References
|
|---|
- Swaye PS, Fisher LD, Litwin P, et al. Aneurysmal coronary artery disease Circulation 1983;67:134-138.[Abstract/Free Full Text]
- Moriyama Y, Hisatomi K, Shimokawa S, et al. Coronary artery aneurysm repaired with saphenous vein patch plasty Ann Thorac Surg 1998;65:561-562.[Abstract/Free Full Text]
- Aqel RA, Zoghbi GJ, Iskandrian A. Spontaneous coronary artery dissection, aneurysm, and pseudoaneurysms: a review Echocardiography 2004;21:175-182.[Medline]
- Sapin R, Frantz E, Jain A, et al. Coronary artery fistula: an abnormality affecting all age groups Medicine 1990;69:101-113.[Medline]
- Hurst JW, Schlant RC, Rackley CE, et al. The heart: arteries and veins7th ed.. New York, NY: McGraw-Hill Inc; 1990. pp. 1233-1234.
- Sexena P, Konstantinov IE, Burstow D, et al. Surgical repair of a large coronary artery aneurysm with arteriovenous fistula J Thorac Cardiovasc Surg 2006;131:1167-1168.[Free Full Text]
- Cheung DL, Au WK, Cheung HH, et al. Coronary artery fistulas: long-term results of surgical correction Ann Thorac Surg 2001;71:190-195.[Abstract/Free Full Text]