ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Jens Wippermann
Johannes M. Albes
Martin Breuer
Mirko Kaluza
Justus Strauch
Thorsten Wahlers
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wippermann, J.
Right arrow Articles by Wahlers, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wippermann, J.
Right arrow Articles by Wahlers, T.
Related Collections
Right arrow Coronary disease

Ann Thorac Surg 2006;82:1134-1136
© 2006 The Society of Thoracic Surgeons


How to do it

Simple On-Site Assembled Blower-Mister Device Provides Sufficient Humidification and Visualization in Off-Pump Surgery

Jens Wippermann, MDa,*, Johannes M. Albes, MD, PhDb, Kai Liebing, Martin Breuer, MDa, Mirko Kaluzaa, Justus Strauch, MDa, Thorsten Wahlers, MD, PhDa

a Department of Cardiothoracic and Vascular Surgery, University Hospital Jena, Jena-Lobeda, Germany
b Heart Center Brandenburg, Bernau, Germany

Accepted for publication July 13, 2005.

* Address correspondence to Dr Wippermann, Department of Cardiothoracic and Vascular Surgery, University Hospital Jena, Erlanger Allee 101, Jena-Lobeda, 07747 Germany (Email: jens.wippermann{at}med.uni-jena.de).


    Abstract
 Top
 Abstract
 Introduction
 Technique
 Comment
 References
 
To effectively perform an anastomosis on a coronary artery under beating heart conditions, the anastomotic site must be cleared of blood to allow visualization for accurate suturing. We describe a simple, cost effective, on-site assembled blower-mister system.


    Introduction
 Top
 Abstract
 Introduction
 Technique
 Comment
 References
 
In off-pump coronary artery bypass grafting and in minimally invasive coronary procedures, optimal view of the anastomosis site is essential for anastomosis quality. However, coronary blood flow frequently compromises a clear view of the opened coronary vessel. Several visualization devices are available on the market to create a perfectly bloodless surgical field. Humidified air has been shown to safely and effectively clear arteriotomies of excessive blood, thereby supporting accuracy and expedition of suturing. We developed a simple blower-mister device that can easily be reproduced. The device provides excellent visualization by delivering a controllable amount of humidified carbon dioxide (CO2).


    Technique
 Top
 Abstract
 Introduction
 Technique
 Comment
 References
 
A standard pressure monitoring line of 180 cm in length provides CO2 flow, whereas a standard intravenous set allows inflow of saline solution. Both lines are connected with a three-way stop-cock connected to a bulbous steel cannula of 1.2 mm or 1.5 mm inner diameter. The set is compatible with all standard equipment in a conventional cardiovascular operating room. Although the fluid line can be connected to a standard infusion, the gas line is connected to a standard medical carbon dioxide source (Fig 1). The gas line is armed with a micro-filter. The device delivers a constant jet of humidified CO2 to effectively eliminate blood from the anastomotic site. The bulbous cannula is kept at a distance of 5 to 10 cm from the coronary artery and allows precise targeting of the humidified CO2 jet. With the standard calibrated inflow valve the CO2 jet can be adjusted and controlled. In our experience, optimum CO2 flow ranges between 1 and 4 L/min depending on the diameter of the respective cannula. As cannulas of different gauge can be used, the system readily adapts to the individual size of the patient's coronary artery. Sufficient humidification of the CO2 stream was maintained by constant flow of saline between 20 and 50 mL/min. In order to prevent desiccation of the graft and the surrounding tissue we evaluated the appropriate velocity and power of the jet in cadaveric pig hearts and thereafter during initial clinical application on the beating heart. We arrived at an optimum CO2 jet pressure ranging from 50 to 150 mm Hg measured by a pressure transducer temporarily incorporated into the system. When using pressure less than 50 mm Hg the field was not entirely cleared, whereas using pressure greater than 150 mm Hg the tissue in the surgical field was dry (Table 1).


Figure 1
View larger version (98K):
[in this window]
[in a new window]
 
Fig. 1. Components of the blower-mister system (from left to right): flow-regulator of the carbon dioxide source, filter, bulbous cannula, and intravenous bag with pressure cuff.

 

View this table:
[in this window]
[in a new window]
 
Table 1. Effective Pressure Dependent on Gas Flow and Cannula-Size
 

    Comment
 Top
 Abstract
 Introduction
 Technique
 Comment
 References
 
Good visualization is essential for anastomosis quality in off-pump surgery. Two features are important: (1) proper visualization of the anastomosis site regarding blood flow and (2) prevention of endothelial damage. Several techniques have been developed that aim at the provision of a bloodless field during the anastomosis procedure. For occlusion of the coronary artery and stabilization of the target vessel, encircling tourniquet sutures have been applied proximal and distal to the area of anastomosis [1, 2]. As an alternative, temporary intraluminal shunts were developed allowing blood supply to the myocardium distal to the anastomosis [3].

We recently demonstrated the superiority of intraluminal shunts in comparison with tourniquet occlusion in terms of preservation of intimal integrity in a chronic study [4]. The efficiency of hemostatic tourniquet occlusion is limited as it may provoke coronary intimal lesions when applied with too much force. On the other hand, residual flow into the anastomotic region may still occur even with an appropriately (slightly oversized) sized intraluminal shunt in place. Fortunately residual blood flow can be eliminated by using a blower. However, high velocity air jets can desiccate the intima with the consequence of irreversible endothelial damage. A simple and ingenious solution for this problem was found by humidifying the air blown onto the site of the anastomosis. Using scanning electron micrographs, Okazaki and colleagues [5] and Hoerstrup and colleagues [6] demonstrated that application of humidified gas by the so-called "blower-mister" did indeed prevent alteration of endothelial cells.

Blower-misters for off-pump procedures are now commercially available. However they are disposable devices and they are quite expensive. In the light of increasing budgetary restrictions we searched for a simple, cost-effective alternative to those devices. In an initial feasibility study, which was approved by the Animal Care and Use Committee of the Friedrich Schiller University Jena, our simplified blower-mister was evaluated on cadaveric pig hearts with no negative side effects on the intima. Thereafter we used the blower during clinical beating heart procedures. In an early experience with 56 patients and a total of 123 coronary anastomoses, we did not find signs of marked desiccation or intimal trauma of either the graft or the coronary artery, whereas a clear view of the anastomosis was maintained even in the presence of considerable residual coronary blood flow. Therefore we consider our invention as safe, efficient, comfortable, and particularly attractive for monetary reasons; roughly estimated the disposable components: pressure line, transfusion set, and micro-filter costs are less than 4 Euro ($4 to $5 Euro), and the standard bulbous steel cannula can be resterilized. We used CO2 instead of O2 because of the 20-fold higher solubility of CO2 in blood. Theoretically these properties can minimize air embolization of the coronary arteries, which were described in case report forms by other authors [7, 8]. Furthermore, consequent use of an intraluminal shunt may help to prevent any air embolization because of the occlusion provided by the shunt olives.

In conclusion, a useful blower-mister with excellent clinical performance can be assembled on-site utilizing standard components with very cost-attractive conditions and special equipment is not required.


    References
 Top
 Abstract
 Introduction
 Technique
 Comment
 References
 

  1. Cremer J, Strüber M, Wittwer T, et al. Off-bypass coronary bypass grafting via minithoracotomy using mechanical epicardial stabilization Ann Thorac Surg 1997;63:79-83.
  2. Calafiore AM, Teodori G, Di Giammarco G, et al. Minimally invasive coronary artery bypass on a beating heart Ann Thorac Surg 1997;63:72-75.
  3. Menon AK, Albes JM, Oberhoff M, Karsch KR, Ziemer G. Occlusion versus shunting during MIDCABeffects on the left ventricular function and quality of ananstomosis. Ann Thorac Surg 1998;66:1082-1086.[Abstract/Free Full Text]
  4. Wippermann J, Albes JM, Bruhin R, et al. Chronic ultrastructural effects of temporary intraluminal shunts in a porcine off-pump model Ann Thorac Surg 2004;78:543-548.[Abstract/Free Full Text]
  5. Okazaki Y, Takarabe K, Murayama J, Suenaga E, et al. Coronary endothelial damage during off-pump CABG related to coronary-clamping and gas insufflation Eur J Cardiothorac Surg 2001;19:834-839.[Abstract/Free Full Text]
  6. Hoerstrup SP, Lachat ML, Zünd G, Vogt PR, Turina MI. Improved visualization in minimally invasive coronary bypass grafting Ann Thorac Surg 1998;66:963-964.[Abstract/Free Full Text]
  7. Brown K, Sabetai M, Venn G. Gas embolization from the left ventricle and aortic roota possible side effect of high flow gas insufflation during coronary artery surgery. Ann Thorac Surg 2004;78:387-388.[Free Full Text]
  8. Nollert G, Oberhoffer M, Reichart B, Vicol C. Combination of the heartstring proximal seal system with a blower mistera possible source of gas emboli. J Thorac Cardiovasc Surg 2003;126:1192-1194.[Free Full Text]




This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Jens Wippermann
Johannes M. Albes
Martin Breuer
Mirko Kaluza
Justus Strauch
Thorsten Wahlers
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wippermann, J.
Right arrow Articles by Wahlers, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wippermann, J.
Right arrow Articles by Wahlers, T.
Related Collections
Right arrow Coronary disease


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS