|
|
||||||||
Ann Thorac Surg 2003;75:870-873
© 2003 The Society of Thoracic Surgeons
a Department of Cardiothoracic Surgery, John Radcliffe Hospital, Oxford, United Kingdom
Accepted for publication September 27, 2002.
* Address reprint requests to Dr Taggart, Department of Cardiothoracic Surgery, John Radcliffe Hospital, Oxford, OX3 9DU, United Kingdom
e-mail: david.taggart{at}orh.nhs.uk
| Abstract |
|---|
|
|
|---|
METHODS: Graft patency was assessed in patients undergoing off-pump and on-pump total arterial revascularization. The imaging technique requires injection of a 1-mL bolus of Indocyanine Green into the central venous line, followed by imaging with the SPY system.
RESULTS: We assessed intraoperative graft patency in 213 conduits in 84 patients (mean, 2.54 grafts per patient), of which, 65 (77%) were done off-pump. It took approximately 3 minutes to image each graft. Skeletonized conduits provided better visualization than pedicled ones. Fluorescence, confirming graft patency, was observed in all but four (1.9%) conduits in 4 (5%) patients. In these latter cases, graft revision was necessitated.
CONCLUSIONS: Fluorescence imaging of coronary grafts using the SPY is a uniquely simple, safe, noninvasive, and reproducible technique for intraoperative confirmation of graft patency. In 4 patients, it necessitated revision of the initial intraoperative procedure. Quantification of graft flow would enhance the value of the system.
| Introduction |
|---|
|
|
|---|
Consequently, several techniques have been employed to assess intraoperative graft patency. These have included electromagnetic [5], ultrasound flow measurement [6], Doppler velocity waveform [7], epicardial echocardiographic [8], and conventional [9] and thermal coronary angiography [10] techniques. However, all have limitations and frequently provide indirect or poor resolution definition of the grafts and flow, as well as being subject to misinterpretation, as they are particularly operator dependent. Conventional coronary angiography remains the gold standard [9], but is highly invasive (requiring arterial puncture), increases operating time, and is infrequently available in the operating theater.
We describe our preliminary experience with a novel, simple, and rapid imaging technique for intraoperative assessment of coronary grafts. The technique is based on capture, by a charge-coupled device video camera, of fluorescence of Indocyanine Green (ICG) when illuminated with near infrared light using laser energy from the SPY imaging system (Novadaq Technologies Inc., Toronto, Canada).
| Material and methods |
|---|
|
|
|---|
As ICG binds to plasma proteins it is confined to the intravascular compartment. ICG fluoresces when illuminated at 806 nm (near infrared light) using laser energy, and the fluorescence is captured by a charge-coupled device video camera at a rate of 30 images per second. The laser used by the SPY system has a total output of 2.2 W spread over an area of 7.5 x 7.5 cm on the surface of the heart, avoiding the risk of thermal myocardial damage and eliminating any risk to the operating theater staff. Indocyanine Green (ICG) has been used for many years in ophthalmic video-angiography and is a very safe compound, with a reported risk of minor adverse reactions of less than one in a thousand.
After completion of the distal coronary artery anastomosis, 1 mL of ICG dye is injected through the central venous line and flushed through with 5 mL of normal saline. Screening is started at the time of injection, and the grafts are imaged as the fluorescent dye passes through them. Images are then recorded on videotape or computer hard drive. The procedure takes 3 to 4 minutes per anastomosis.
| Results |
|---|
|
|
|---|
|
Imaging took approximately 3 minutes per graft. Flow was visualized in all grafts confirming patency, and in the majority resulted in images of similar quality to that observed with conventional angiography (see Figs 14). As for conventional angiography, the still image is more difficult to interpret than the moving image. Although the anastomotic site was clearly visualized in three-quarters of cases, it was not usually possible to demonstrate precise anatomical detail. Skeletonized conduits (ie, internal thoracic arteries and radial arteries) permitted better visualization than pedicled ones.
|
|
|
A 77-year-old patient underwent OPCABG including a left internal thoracic artery (LITA) to the left anterior descending artery (LAD) and right internal thoracic artery (RITA) to the distal right coronary artery (RCA). Flow in the LITA to the LAD was poorly visualized (Fig 1A), suggesting either an anastomotic problem or the presence of disease distal to the anastomosis. Consequently, a vein graft was placed to the distal coronary artery with excellent flow (Fig 1B).
A 55-year-old patient with single-vessel disease and good left ventricular function underwent LITA to LAD on pump. Flow in the LITA to the LAD was not visualized. The graft was revised and the anastomosis reconstructed distally, with excellent flow (Fig 2).
A 66-year-old patient with three-vessel disease underwent OPCABG, including an in situ RITA to the LAD and radial artery (RA) to the obtuse marginal coronary artery (OM). The proximal end of the RA was attached to the side of the RITA. The flow in the RITA to the LAD beyond the RITA-to-RA anastomosis was not visualized (Fig 3A). The RITA-to-RA anastomosis was reconstructed, with excellent flow (Fig 3B).
A 57-year-old patient with three-vessel disease and good left ventricular function underwent OPCABG, including an in situ RITA to the LAD and an in situ LITA to OM. The flow in the LITA to the OM was not visualized (Fig 4A). The LITA-to-OM was reconstructed distal to the initial site and adequate flow was visualized (Fig 4B).
|
| Comment |
|---|
|
|
|---|
To our knowledge, this is the first report describing the use of this novel technique in the intraoperative setting of coronary artery surgery. Our preliminary results demonstrate that the SPY imaging system, based on fluorescence of ICG, is a safe, simple, rapid, repeatable method for the intraoperative assessment of graft conduits.
The strengths of the technique are its simplicity and safety. It is minimally invasive in that no arterial puncture is required, and avoids the need for ionizing radiation. ICG has been very widely used in a variety of clinical situations, and adverse reactions are very uncommon, having been reported in the region of 0.004% [12]. In most situations, the graft was well visualized within 3 minutes and provided semiquantitative estimates of flow with real-time images. A major attraction is that it provides information in a fashion similar to coronary angiography, with which the surgeon is familiar and can easily interpret.
The value of the imaging system was illustrated by altering the intraoperative management of 4 patients, highlighting that graft flow compromise occurred in 5% of patients in this series and in 1.9% of all performed grafts.
There are currently limitations to the technique. First, the technique is only semiquantitative, in that it permits assessment of graft flow as "excellent," "satisfactory," or "poor," but does not provide an exact measure of graft flow. Developments are currently underway that will permit the imaging system to give quantitative flow measurements. Second, the technique only allows precise definition of anastomotic quality in around three-quarters of grafts. This is because depth of penetration of the laser beam is only around 1 mm, and is therefore vulnerable to varying depths of the native coronary artery (eg, when intramyocardial). For the same reason, imaging can only occur when the chest is open and pedicled conduits are less well visualized than skeletonized ones. A more powerful, pulsed laser might resolve these limitations, and would be balanced against the fact that the device intentionally uses low-power laser energy so as to avoid thermal myocardial damage.
Conclusions
The fluorescence imaging technique of coronary grafts that is described has the advantages of safety, simplicity, reproducibility, repeatability, speed of assessment, and allows immediate surgical revision if necessary. Quantification of flow would further enhance its value.
| Acknowledgments |
|---|
|
|
|---|
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
T. Handa, R. G. Katare, S. Sasaguri, and T. Sato Preliminary experience for the evaluation of the intraoperative graft patency with real color charge-coupled device camera system: an advanced device for simultaneous capturing of color and near-infrared images during coronary artery bypass graft Interactive CardioVascular and Thoracic Surgery, August 1, 2009; 9(2): 150 - 154. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Tanaka, F. Y. Chen, R. Flaumenhaft, G. J. Graham, R. G. Laurence, and J. V. Frangioni Real-time assessment of cardiac perfusion, coronary angiography, and acute intravascular thrombi using dual-channel near-infrared fluorescence imaging J. Thorac. Cardiovasc. Surg., July 1, 2009; 138(1): 133 - 140. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. P Taggart, L. Balacumaraswami, and A. Venkatapathy Radial Artery Jump Graft from Anterior to Posterior Descending Coronary Artery Asian Cardiovasc Thorac Ann, April 1, 2009; 17(2): 143 - 146. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. D. Desai, F. Moussa, S. K. Singh, P. Chu, and S. E. Fremes Intraoperative fluorescence angiography to determine the extent of injury after penetrating cardiac trauma J. Thorac. Cardiovasc. Surg., July 1, 2008; 136(1): 218 - 219. [Full Text] [PDF] |
||||
![]() |
L. Balacumaraswami, Y. Abu-Omar, J. Selvanayagam, D. Pigott, and D. P. Taggart The effects of on-pump and off-pump coronary artery bypass grafting on intraoperative graft flow in arterial and venous conduits defined by a flow/pressure ratio J. Thorac. Cardiovasc. Surg., March 1, 2008; 135(3): 533 - 539. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. A. Bockeria, A. S. Karamatov, T. G. Le, and T. M. Venglinskaya Intra-operative diagnostics of surgical stenoses of coronary arteries. Interactive CardioVascular and Thoracic Surgery, February 1, 2008; 7(1): 162 - 163. [Full Text] [PDF] |
||||
![]() |
F. A. Jaffer, P. Libby, and R. Weissleder Molecular Imaging of Cardiovascular Disease Circulation, August 28, 2007; 116(9): 1052 - 1061. [Full Text] [PDF] |
||||
![]() |
C. Detter, S. Wipper, D. Russ, A. Iffland, L. Burdorf, E. Thein, K. Wegscheider, H. Reichenspurner, and B. Reichart Fluorescent Cardiac Imaging: A Novel Intraoperative Method for Quantitative Assessment of Myocardial Perfusion During Graded Coronary Artery Stenosis Circulation, August 28, 2007; 116(9): 1007 - 1014. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Balacumaraswami and D. P. Taggart Intraoperative Imaging Techniques to Assess Coronary Artery Bypass Graft Patency Ann. Thorac. Surg., June 1, 2007; 83(6): 2251 - 2257. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. E. Sosnovik, M. Nahrendorf, N. Deliolanis, M. Novikov, E. Aikawa, L. Josephson, A. Rosenzweig, R. Weissleder, and V. Ntziachristos Fluorescence Tomography and Magnetic Resonance Imaging of Myocardial Macrophage Infiltration in Infarcted Myocardium In Vivo Circulation, March 20, 2007; 115(11): 1384 - 1391. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. Hassanein, A. Albert, I. Florath, Y. Y. Hegazy, U. Rosendahl, S. Bauer, and J. Ennker Concomitant aortic valve replacement and coronary bypass: the effect of valve type on the blood flow in bypass grafts Eur. J. Cardiothorac. Surg., March 1, 2007; 31(3): 391 - 396. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Flaumenhaft, E. Tanaka, G. J. Graham, A. M. De Grand, R. G. Laurence, K. Hoshino, R. J. Hajjar, and J. V. Frangioni Localization and Quantification of Platelet-Rich Thrombi in Large Blood Vessels With Near-Infrared Fluorescence Imaging Circulation, January 2, 2007; 115(1): 84 - 93. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Di Giammarco, M. Pano, S. Cirmeni, P. Pelini, G. Vitolla, and M. Di Mauro Predictive value of intraoperative transit-time flow measurement for short-term graft patency in coronary surgery. J. Thorac. Cardiovasc. Surg., September 1, 2006; 132(3): 468 - 474. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. R. McVeigh Emerging Imaging Techniques Circ. Res., April 14, 2006; 98(7): 879 - 886. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. D. Desai, S. Miwa, D. Kodama, G. Cohen, G. T. Christakis, B. S. Goldman, M. O. Baerlocher, M. P. Pelletier, and S. E. Fremes Improving the Quality of Coronary Bypass Surgery With Intraoperative Angiography: Validation of a New Technique J. Am. Coll. Cardiol., October 18, 2005; 46(8): 1521 - 1525. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Balacumaraswami, Y. Abu-Omar, B. Choudhary, D. Pigott, and D. P. Taggart A comparison of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency J. Thorac. Cardiovasc. Surg., August 1, 2005; 130(2): 315 - 320. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Yasuda, G. Watanabe, and S. Tomita Transaortic injection technique in fluorescence imaging: Novel intraoperative assessment of anastomosis in off-pump coronary artery bypass grafting J. Thorac. Cardiovasc. Surg., August 1, 2005; 130(2): 560 - 561. [Full Text] [PDF] |
||||
![]() |
T. D.L. Keenan, Y. Abu-Omar, and D. P. Taggart Bypassing the Pump: Changing Practices in Coronary Artery Surgery Chest, July 1, 2005; 128(1): 363 - 369. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. P.J. Budde, T. C. Dessing, R. Meijer, P. F.A. Bakker, C. Borst, and P. F. Grundeman Robot-assisted 13 MHz epicardial ultrasound for endoscopic quality assessment of coronary anastomoses Interactive CardioVascular and Thoracic Surgery, December 1, 2004; 3(4): 616 - 620. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Takahashi, T. Ishikawa, K. Higashidani, and H. Katoh SPYTM: an innovative intra-operative imaging system to evaluate graft patency during off-pump coronary artery bypass grafting Interactive CardioVascular and Thoracic Surgery, September 1, 2004; 3(3): 479 - 483. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Balacumaraswami, Y. Abu-Omar, K. Anastasiadis, B. Choudhary, D. Pigott, S.-K. Yeong, and D. P. Taggart Does off-pump total arterial grafting increase the incidence of intraoperative graft failure? J. Thorac. Cardiovasc. Surg., August 1, 2004; 128(2): 238 - 244. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. A. Jaffer, C.-H. Tung, J. J. Wykrzykowska, N.-H. Ho, A. K. Houng, G. L. Reed, and R. Weissleder Molecular Imaging of Factor XIIIa Activity in Thrombosis Using a Novel, Near-Infrared Fluorescent Contrast Agent That Covalently Links to Thrombi Circulation, July 13, 2004; 110(2): 170 - 176. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. B. Selvanayagam, S. E. Petersen, J. M. Francis, M. D. Robson, A. Kardos, S. Neubauer, and D. P. Taggart Effects of Off-Pump Versus On-Pump Coronary Surgery on Reversible and Irreversible Myocardial Injury: A Randomized Trial Using Cardiovascular Magnetic Resonance Imaging and Biochemical Markers Circulation, January 27, 2004; 109(3): 345 - 350. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |