|
|
||||||||
Ann Thorac Surg 2002;74:678-683
© 2002 The Society of Thoracic Surgeons
a Department of Cardiovascular Surgery, National Kanazawa Hospital, Kanazawa, Japan
b Department of General and Cardio-thoracic Surgery, Kanazawa University School of Medicine, Kanazawa, Japan
Accepted for publication May 1, 2002.
* Address reprint requests to Dr Matsumoto, Department of Cardiovascular Surgery, National Kanazawa Hospital, 1-1 Shimoishibikicho, Kanazawa, 920-8650, Japan
e-mail: matumoto{at}kinbyou.hosp.go.jp
| Abstract |
|---|
|
|
|---|
Methods. A prospective, randomized study was conducted. A total of 50 patients participated in this study after having been allocated to one of two groups. On-pump beating heart valvular operations using retrograde coronary sinus perfusion as myocardial protection were performed in 25 patients (beating heart procedure group: aortic = 8 patients, mitral = 15 patients, double = 2 patients). Twenty-five patients underwent conventional valvular operation using retrograde continuous warm blood cardioplegia (conventional procedure group: aortic = 9 patients; mitral = 13 patients; double = 3 patients). The remaining operative variables and early outcomes of these procedures were compared. In the beating heart procedure group, myocardial tissue oxygen was measured by near infrared spectroscopy, and partial oxygen pressure of coronary sinus perfusion was also measured.
Results. The visual field of the on-pump beating heart was equal to that of conventional valvular operation, and technical accuracy was not compromised. In the beating heart procedure group, tissue oxygen saturation was maintained at 79% ± 2%, and partial oxygen pressure of coronary sinus perfusion blood and returned blood were maintained at 383 ± 29 mm Hg and 38 ± 2 mm Hg, respectively. Postoperative peak creatine kinase-MB (measured every 3 hours postoperatively) and peak troponin T concentrations were significantly lower than those of conventional procedures (17.5 ± 7.8 vs 32.1 ± 9.3 IU/L and 0.12 ± 0.04 vs 0.21 ± 0.06 ng/mL, respectively; p < 0.05). There was no operative mortality and no major complications.
Conclusions. On-pump beating heart valvular operation is a good surgical option, and has advantages because conditions for the heart are more physiologic with beating tonus than with cardioplegia.
| Introduction |
|---|
|
|
|---|
We report on the efficacy and applicability of on-pump beating heart valvular operations using retrograde coronary sinus (CS) perfusion to preserve the myocardium.
| Patients and methods |
|---|
|
|
|---|
On-pump beating heart valvular operations using retrograde CS perfusion as the myocardial protection were performed in 25 patients (11 men and 14 women; mean age, 65.3 ± 9.3 years) with 8 mitral and 15 aortic valvular diseases (2 patients had double valvular disease) (Table 1, beating heart procedure). Also 25 patients underwent conventional valvular operations using retrograde continuous warm blood cardioplegia (9 men and 16 women; mean age, 64.8 ± 7.2 years). This group had 9 mitral, 13 aortic, and 3 double valvular diseases. Clinical data relevant to the operative course of each patient were analyzed. The 23 of 25 patients of the beating heart group and the 24 of 25 patients of the conventional group were classified as New York Heart Association functional class III or IV (with persistent atrial fibrillation, 13 vs 11 patients; or with a previous mitral valve replacement with a bioprosthesis, 1 vs 2 patients). Mean left ventricular ejection fraction of beating heart procedure group was 52.1% ± 13.7%, and that of conventional procedure group was 56.8% ± 15.8%.
|
|
Myocardial tissue oxygen measurement
Intraoperatively, partial oxygen pressure (PCO2) of the CS perfusion blood and the blood from the aortic vent were measured every 15 minutes during CS perfusion in all 25 patients. In aortic procedures, PCO2 was measured using returning blood from the coronary ostia instead of blood from the aortic vent. Simultaneously, myocardial tissue oxygen was measured by three-wavelength near infrared spectroscopy, using a probe specially designed for the heart (PSA-500; Biomedical Science, Kanazawa, Japan) [8]. Near infrared light passes through tissues easily and is significantly absorbed by oxygenated and deoxygenated hemoglobin, which have distinctly different absorption spectra in the near infrared region. This difference in absorption spectra can be used to measure changes in the tissue concentration of oxygen. The probe contains 3 light-emitting diodes as light sources and 3 pairs of silicone photodiodes to detect the intensity of reflected light. The probe was used with a suction stabilizing system to avoid intraoperative handling, and was attached to the anterior surface of the right ventricle. Optical information from a myocardial tissue depth of 2.5 to 5.0 mm was obtained. The near infrared signal was analyzed using a set of algorithms that solve for oxygenated and deoxygenated hemoglobin. Tissue oxygen saturation (SO2) was calculated by dividing oxygenated hemoglobin by the sum of oxygenated and deoxygenated hemoglobin. We also evaluated the early outcomes of the patients of both groups.
Statistical analysis
Continuous variables were expressed as mean ± standard deviation, and statistical analysis was performed using Students t test to detect significant (p < 0.05) differences between measured variables. Categorical variables, expressed as percentages, were analyzed using Pearsons
2 test or Fishers exact test.
| Results |
|---|
|
|
|---|
|
|
There was no operative mortality and no occurrence of major complications such as low output syndrome, bleeding requiring reexploration, cerebral infarction, perioperative myocardial infarction, and mediastinitis.
| Comment |
|---|
|
|
|---|
In the present study, postoperative levels of creatine kinase MB, troponin T, and required levels of catecholamine were significantly lower in the beating heart patients. Consistent with these results is the present finding that maintenance of the heart in a beating state throughout the operation results in less damage than cardioplegic arrest, even when blood cardioplegia is used in a continuous fashion. Intraoperative monitoring showed that retrograde CS perfusion maintained myocardial SO2 at levels almost identical to preoperative physiologic values throughout the procedure, and that PO2 of CS perfusion blood and returned blood was maintained at 383 ± 29 mm Hg and 38 ± 2 mm Hg, respectively. This difference in PO2 values indicates that an aerobic myocardial environment was maintained by retrograde CS perfusion.
Despite motion of the heart, the on-pump and well-decompressed state of the heart caused by cardiac venting resulted in quality of visual field equal to that of conventional valvular operations, and technical accuracy was not compromised. Moreover, in cases of mitral valvuloplasty, the three-dimensional architecture of the beating heart provided a good opportunity to examine the mitral valve under more physiologic conditions than cardioplegic arrested state, before, during, and after completion of the repair. With conventional techniques, the mitral valve is in a motionless, flaccid state that may not accurately reflect its function in the beating heart.
We were able to perform intraoperative electrophysiologic examination of the beating heart during the procedure to ablate atrial fibrillation. First, we performed pulmonary vein isolation (the simpler method of elimination of atrial fibrillation) [11] with monitoring of intrapulmonary venous potentials. In cases in which atrial fibrillation was not eliminated by pulmonary vein isolation, we were able to perform the full Maze procedure on the beating heart using radio-frequency energy [12] instead of cryo-coagulation.
When considering the applicability of on-pump beating heart valvular operations, retrograde myocardial perfusion is a very important factor. Retrograde CS perfusion as a method of myocardial preservation is not novel. In 1956, Lillehei and colleagues [13] reported a case of an aortic valve operation using this technique with retrograde CS perfusion flow at 125 mL/min. In recent years, this procedure has not been used because of advances in cardioplegic arrest technique. However, beating heart valvular operations using retrograde CS perfusion may be revived as a surgical option for valvular disease. The advantages of retrograde CS perfusion include: (1) avoidance of injury and postcannulation ostial stenosis of the coronary arteries; (2) performance of surgical procedures (especially aortic procedures) without interruption; (3) a long period of continuous oxygenated blood delivery, which maintains beating of the heart and appropriate pH, and allows effective delivery of substrates or drugs and removal of acid metabolites; and (4) more uniform oxygenated blood distribution in the presence of coronary artery stenosis or obstruction.
The optimal level of retrograde CS perfusion flow is unknown. Resting coronary blood flow in humans averages approximately 225 mL per minute, which is about 0.7 to 0.8 mL per gram of heart muscle, or 4% to 5% of total cardiac output [14]. However patients with a hypertrophied heart (eg, patients with valvular disease) require high flow rates of retrograde perfusion for adequate myocardial protection, thus necessitating the use of high pressures during retrograde CS perfusion. Therefore, we maintained the highest possible safe level of CS perfusion flow (minimum, 300 mL/min; mean, 418 ± 42 mL/min) to avoid adverse effects of hypoperfusion.
The optimal safe perfusion pressure during retrograde CS perfusion is closely related to CS perfusion flow. High pressure is required to maintain more than 300 ml/min CS perfusion flow. Because initial experiments by Beck and colleagues [15] and others on working, beating dog hearts showed that hemorrhage occurs at pressures greater than 40 to 60 mm Hg, it has generally been recommended that CS pressure be kept below these levels. In an experimental study of retrograde CS perfusion by Eke and colleagues [16], they found that CS pressure up to 120 mm Hg caused no extravasation of blood into the myocardium in a vented and arrested heart. Under microscopic examination, their heart tissue slices showed normal structures. Because the present procedures were performed in vented, beating, unburdened hearts, we believe that the coronary sinus was able to withstand somewhat higher pressure (60 to 80 mm Hg) during retrograde heart perfusion than the range described previously. Also, we used phosphodiesterase III inhibitor as a vasodilator to increase CS perfusion flow. We found no complications related to retrograde CS perfusion, even at a pressure of 60 mm Hg [17], and we maintained a high perfusion rate.
In this procedure, removal of air after aortic declamping is important. The air evacuation was performed using the remained aortic venting tube continuously until the end of cardiopulmonary bypass. The air removal was confirmed by monitoring with transesophageal echocardiography. No episode of air embolism was experienced in our study.
In the present patients, there was no failure of CS perfusion. However, in other series, we experienced a patient with malperfusion. The patient had repeated ventricular fibrillation during retrograde perfusion despite the cardioversion. Retrograde coronary sinus perfusion flow rate at that time was only 180 mL/min and SO2 fell to approximately 50%. So we immediately abandoned the beating heart procedure and used antegrade cardioplegic arrest technique. If ventricular fibrillation is observed during the beating heart procedure, this technique should be abandoned because malperfusion is strongly suggested.
Also, when retrograde CS perfusion could not have been continued, we would have been able to switch from retrograde CS perfusion to retrograde continuous warm blood cardioplegia. However, if myocardial malperfusion is suspected, it may be better to use antegrade infusion of cardioplegia. The most important points of this procedure are to maintain high coronary sinus perfusion flow rate and to keep adequate venting.
The present results indicate that an on-pump beating heart valvular operation is a good surgical option for valvular disease. The advantages of on-pump beating heart valvular operations are due to the fact that the heart is under more physiologic conditions than cardioplegic arrested state with left ventricular beating tonus, thus eliminating adverse effects of global myocardial ischemia produced from reperfusion injury. However the efficacy of this procedure requires further study using larger prospective randomized trials comparing this method with cardioplegic arrest methods.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
J. Kempfert, J. M. Blumenstein, M. A. Borger, A. Linke, S. Lehmann, P. Pritzwald-Stegmann, M. W.A. Chu, G. Schuler, V. Falk, F. W. Mohr, et al. Minimally invasive off-pump valve-in-a-valve implantation: the atrial transcatheter approach for re-operative mitral valve replacement Eur. Heart J., June 20, 2008; (2008) ehn285v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Wang, H. Liu, T. A. Salerno, B. Xiang, G. Li, M. Gruwel, M. Jackson, D. Manley, B. Tomanek, R. Deslauriers, et al. Does Normothermic Normokalemic Simultaneous Antegrade/Retrograde Perfusion Improve Myocardial Oxygenation and Energy Metabolism for Hypertrophied Hearts? Ann. Thorac. Surg., May 1, 2007; 83(5): 1751 - 1758. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Battellini, A. J. Rastan, A. Fabricius, M. Moscoso-Luduena, N. Lachmann, and F. W. Mohr Beating Heart Aortic Valve Replacement After Previous Coronary Artery Bypass Surgery With a Patent Internal Mammary Artery Graft Ann. Thorac. Surg., March 1, 2007; 83(3): 1206 - 1209. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. A. Lotto and W. A. Owens Intraoperative Doppler Velocity Measurements to Locate Patent ITA Grafts at Reoperation. Ann. Thorac. Surg., September 1, 2006; 82(3): 1108 - 1110. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Shanmugam Aortic valve replacement following previous coronary surgery Eur. J. Cardiothorac. Surg., November 1, 2005; 28(5): 731 - 735. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Ueda, T. Kawata, H. Sakaguchi, N. Tabayashi, T. Abe, T. Hirose, and S. Taniguchi Aortic valve replacement in a patient with a patent internal thoracic artery graft Ann. Thorac. Surg., February 1, 2004; 77(2): 718 - 720. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Masroor, H. Tehrani, and T. A. Salerno Beating heart valvular surgery Ann. Thorac. Surg., September 1, 2003; 76(3): 973 - 973. [Full Text] [PDF] |
||||
![]() |
Y. Matsumoto Reply Ann. Thorac. Surg., September 1, 2003; 76(3): 973 - 973. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |