| Abstract |
|---|
|
|
|---|
Methods. We conducted an electrophysiologic study of atrial flutter and determined its reentry circuit on the atrium. We consider how to reduce atrial flutter after the left-sided simple maze procedure.
Results. Common atrial flutter through the right atrial isthmus was induced in all 4 patients, and linear ablation on the right atrial isthmus was effective in 3 of these. An incisional atrial flutter around the right atriotomy was also induced in 2 of 4 patients; both were successfully treated by linear ablation between the right atriotomy and the inferior vena cava.
Conclusions. Common atrial flutter through the right atrial isthmus is a risk after the left-sided simple maze procedure. When a left-sided simple maze procedure is performed, sufficient cryoablation on the right atrial isthmus of the arrested heart should be administered to prevent postoperative atrial flutter.
| Introduction |
|---|
|
|
|---|
| Patients, methods, and results |
|---|
|
|
|---|
Surgery and electrophysiologic study
Patient 1 was a 55-year-old man who had experienced chronic atrial fibrillation for 10 years as a result of combined rheumatic valvular disease. His aortic and mitral valves were replaced with mechanical valves at the same time as a left-sided simple maze procedure was performed, but no cryoablation was delivered at the right atrial isthmus. The patients normal sinus rhythm recovered but he suffered several postoperative episodes of paroxysmal atrial flutter (heart rate 140 beats/min). An electrophysiologic study indicated two kinds of atrial flutter: a counterclockwise common atrial flutter through the right atrial isthmus, and a left atrial tachycardia (see 1 and 4 in Fig 1).
Radio-frequency ablation (RFA) was performed to create an anatomical linear block on the right atrial isthmus 11 months after surgery (11 times and total 12,407J; see area (a) of Fig 1). No more episodes of atrial flutter took place.
|
Patient 3 was a 56-year-old woman with a 10-year history of chronic atrial fibrillation due to mitral valve stenosis. She had undergone mitral valve replacement with a mechanical valve, combined with a left-sided simple maze procedure. No cryoablation was performed at the right atrial isthmus. Normal sinus rhythm was restored, but several times the patient experienced faintness due to paroxysmal atrial flutter. An electrophysiologic study performed 3 years after surgery revealed three distinct types of atrial flutter. These were counterclockwise and clockwise common atrial flutter (see 1 and 2 in Fig 1) and an incisional atrial flutter around the right atriotomy (see 3 in Fig 1). A complete linear ablation was created at the right atrial isthmus 30 times, total 70,824J (see area (a) in Fig 1). Another linear ablation between the right atriotomy and the inferior vena cava was made 15 times with a total 32,050J delivery (see area (b) in Fig 1). There were no further episodes of atrial flutter.
Patient 4 was a 56-year-old man who had undergone closed mitral commisurotomy 25 years earlier as a result of mitral valve stenosis. The mitral valve was replaced in response to mitral valve restenosis, and a left-sided simple maze procedure was included to tackle the 25-year history of chronic atrial fibrillation. A total of 60 seconds of cryoablation was delivered at -60°C at the right atrial isthmus through the right atriotomy on the beating heart. The patients sinus rhythm recovered, but atrial flutter then developed and was sustained as a 2:1 block at a heart rate of 130/min. One year after surgery an electrophysiologic study found an incisional atrial flutter around the right atriotomy (see 3 in Fig 1). A linear ablation was created between the right atriotomy and the IVC (22 times, total 30,152J; see area (b) in Fig 1). The incisional atrial flutter was cured, although a counterclockwise common atrial flutter through the right atrial isthmus remained (2:1 block and 100/min heart rate).
| Comment |
|---|
|
|
|---|
Incomplete or delayed recovery of sinus node function is a major complication of the original maze procedure because of major transect variations of the sinus node arteries. The incidence of sick sinus syndrome, which necessitated the implantation of a cardiac pacemaker, has been reported as 3.2% to 25% [1, 2, 4, 5]. The absence of invasion of the sinus node area is a further advantage of the left-sided simple maze procedure. This shortens the time needed for recovery of sinus node function and reduces the incidence of sick sinus syndrome. In our series, 4 patients required more than 1 week of temporary cardiac pacing as a result of delayed recovery of sinus node function after left-sided simple maze procedures (10%, n = 41). The incidence of sick sinus syndrome is 32% for modified Coxs maze III procedures (n = 32; p = 0.0418,
2 test). Cardiac pacemaker implantations were required in 2 cases after Coxs maze III procedure and in 1 case after the left-sided simple maze procedure, at 2 to 4 months after surgery. The former 2 cases were implanted VVI for sinus bradycardia or sinus arrest, and the last case was performed DDD for sick sinus syndrome with brady and tachycardia.
Paroxysmal atrial tachycardia developed due to atrial flutter in 4 cases (10%) in the left-sided simple maze procedure, but in only 1 case (3%) in Coxs maze III procedure. The left-sided simple maze procedure clearly has a higher incidence of atrial flutter in our series. Common atrial flutter through the right atrial isthmus was induced in all 4 cases, and linear ablation on the right atrial isthmus was effective in 3 of these. An incisional atrial flutter around the right atriotomy was also induced in 2 of these 4 cases; both were cured with a linear ablation between the right atriotomy and the IVC. We consider that common atrial flutter through the right atrial isthmus carries a clear risk after the left-sided simple maze procedure. Therefore, cryoablation between the tricuspid annulus and the IVC on the arrested heart is recommended at a sufficient level to prevent postoperative atrial flutter tachycardia. When a right atriotomy was performed, we delivered 2 minutes of cryoablation several times at -60°C between the tricuspid valvular annulus and the IVC orifice. Additional cryoablation on the outside IVC is effective when the venous cannula or IVC tape obstructs cryoablation.
Around a right atriotomy, incisional atrial flutter is also significant. We therefore recommend that the right atriotomy should be longitudinally, at the lower part of the right atrium, and that additional cryoablation should occur between the atriotomy ridge and the IVC. Imai and colleagues [6] reported that new supraventricular arrhythmia occurred in more than 20% of patients who recovered their sinus rhythm after the left-sided simple maze procedure. They performed RFA in 2 of 32 cases. Linear block of the right atrial isthmus was successful in 1 case, and modification of the atrioventricular node and implantation of a permanent cardiac pacemaker was performed in the others [6]. The modified lesser maze procedures give rise to a higher incidence of recurrent supraventricular arrhythmias than the standard maze procedure.
In our series, possible predictors of postoperative atrial flutter after the left-sided simple maze procedure were evaluated by univariate unconditional logistic regression. Of the variables noted in preoperative clinical profiles and operative factors, only age was significantly associated with a reduced chance of postoperative atrial flutter (odds ratio = 0.879, p = 0.0347). Patients who developed postoperative atrial flutter were significantly younger than other patients (47.7 ± 12.5 vs 60.9 ± 8.7, p = 0.0093). Atrial flutter and atrial fibrillation are both intraatrial reentrant arrythmias, with differing complexity in their activation pattern and mechanism. They frequently coexist in clinical practice [7]; however, it is possible in some cases that postoperative atrial flutter either preexists or develops de novo.
Restoration of sinus rhythm after surgery was at 74% in the left-sided simple maze procedure for our series. There are no significant differences between the rate of 74% reported by Imai and colleagues [6] and the rate that we found for Coxs maze procedure (78% with
2 test, n = 32). Although a left-sided simple maze procedure reduces operative invasiveness without reducing the defibrillation rate, it can be complicated by tachycardia due to atrial flutter. We make no recommendation for the choice of the maze procedure or its modification. When a left-sided simple maze procedure is performed, sufficient cryoablation on the right atrial isthmus should be deployed to prevent postoperative atrial flutter.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
A. M. Patel, A. d'Avila, P. Neuzil, S. J. Kim, MSEE, T. Mela, J. P. Singh, J. N. Ruskin, and V. Y. Reddy Atrial Tachycardia After Ablation of Persistent Atrial Fibrillation: Identification of the Critical Isthmus With a Combination of Multielectrode Activation Mapping and Targeted Entrainment Mapping Circ Arrhythm Electrophysiol, April 1, 2008; 1(1): 14 - 22. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. S.C. Geuzebroek, P. K.E.W. Ballaux, N. M. van Hemel, J. C. Kelder, and J. J.A.M.T. Defauw Medium-term outcome of different surgical methods to cure atrial fibrillation: is less worse? Interactive CardioVascular and Thoracic Surgery, April 1, 2008; 7(2): 201 - 206. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. T. McElderry, D. C. McGiffin, V. J. Plumb, K. Nanthakumar, A. E. Epstein, T. Yamada, and G. N. Kay Proarrhythmic Aspects of Atrial Fibrillation Surgery: Mechanisms of Postoperative Macroreentrant Tachycardias Circulation, January 15, 2008; 117(2): 155 - 162. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Onorati, A. Esposito, G. Messina, A. di Virgilio, and A. Renzulli Right Isthmus Ablation Reduces Supraventricular Arrhythmias After Surgery for Chronic Atrial Fibrillation Ann. Thorac. Surg., January 1, 2008; 85(1): 39 - 48. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. K. Voeller, R. B. Schuessler, and R. J. Damiano Jr. Surgical Treatment of Atrial Fibrillation Card. Surg. Adult, January 1, 2008; 3(2008): 1375 - 1394. [Full Text] |
||||
![]() |
A. M. Gillinov Choice of Surgical Lesion Set: Answers From the Data Ann. Thorac. Surg., November 1, 2007; 84(5): 1786 - 1792. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. A. Mack, F. Milla, W. Ko, L. N. Girardi, L. Y. Lee, A. J. Tortolani, J. Mascitelli, K. H. Krieger, and O. W. Isom Surgical Treatment of Atrial Fibrillation Using Argon-Based Cryoablation During Concomitant Cardiac Procedures Circulation, August 30, 2005; 112(9_suppl): I-1 - I-6. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Golovchiner, A. Mazur, A. Kogan, B. Strasberg, Y. Shapira, M. Fridman, J. Kuzniec, B. A. Vidne, and E. Raanani Atrial Flutter After Surgical Radiofrequency Ablation of the Left Atrium for Atrial Fibrillation Ann. Thorac. Surg., January 1, 2005; 79(1): 108 - 112. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Romano, D. S. Bach, F. D. Pagani, R. L. Prager, G. M. Deeb, and S. F. Bolling Atrial reduction plasty Cox maze procedure: extended indications for atrial fibrillation surgery Ann. Thorac. Surg., April 1, 2004; 77(4): 1282 - 1287. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Akpinar, M. Guden, E. Sagbas, I. Sanisoglu, U. Ozbek, B. Caynak, and O. Bayindir Combined radiofrequency modified maze and mitral valve procedure through a port access approach: early and mid-term results Eur. J. Cardiothorac. Surg., August 1, 2003; 24(2): 223 - 230. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Vijay and J. P. Gold Late Complications of Cardiac Surgery Card. Surg. Adult, January 1, 2003; 2(2003): 521 - 537. [Full Text] |
||||
![]() |
F. Hornero, J. A. Montero, S. Canovas, and M. Bueno Biatrial radiofrequency ablation for atrial fibrillation: epicardial and endocardial surgical approach Interactive CardioVascular and Thoracic Surgery, December 1, 2002; 1(2): 72 - 77. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Gillinov, E. H. Blackstone, and P. M. McCarthy Atrial fibrillation: current surgical options and their assessment Ann. Thorac. Surg., December 1, 2002; 74(6): 2210 - 2217. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |