Ann Thorac Surg 2001;72:1232-1238
© 2001 The Society of Thoracic Surgeons
a Division of Thoracic and Cardiovascular Surgery, University of Florida, Gainesville, Florida, USA
Address reprint requests to Dr Beaver, Division of Thoracic and Cardiovascular Surgery, University of Florida, 1600 SW Archer Rd, Room M602, Gainesville, FL 32610-0286
e-mail: beavetm{at}mail.surgery.ufl.edu
Presented at the Forty-seventh Annual Meeting of the Southern Thoracic Surgical Association, Marco Island, FL, Nov 911, 2000.
| Abstract |
|---|
|
|
|---|
Methods. Under circulatory arrest, the descending thoracic aorta is opened. A wire is passed up to the arch and a graft is brought down and secured excluding the descending thoracic aneurysm. The arch vessels are attached as a single patch and the graft is brought forward, replacing the ascending aorta.
Results. Fourteen patients have undergone single-stage replacement of the ascending, arch, and descending aorta with a 14% mortality rate and 14% incidence of paraplegia.
Conclusions. Patients with aneurysms of the ascending, arch, and descending thoracic aorta can be managed with a single operation with comparable mortality and morbidity of the two-stage approach.
| Introduction |
|---|
|
|
|---|
| Patients and methods |
|---|
|
|
|---|
The patient is placed in a steep Trendelenburg position and the entire ascending aorta is excised and the transverse arch is opened longitudinally. The heart is retracted cephalad and the descending aorta is exposed through the posterior pericardium and opened transversely. A guidewire is passed from the descending aorta up into the arch. A woven Dacron graft is then pulled down into the descending thoracic aorta using the wire as a guide and anastomosed to the descending thoracic aorta at the level of the transverse aortotomy (Fig 1). This anastomosis effectively seals the upper descending thoracic aorta from retrograde flow. The arch vessels are reimplanted in the graft as a single anastomosis and the transverse arch aortotomy is closed around the graft. At this time the graft is inverted and sewn to the aortic wall proximal to the arch vessels, sealing the aorta around the graft effectively excluding the arch and descending aorta from systemic flow and pressure (Fig 2). Collateral vessels feeding the body of the aneurysm appear to thrombose as seen with thoracic stent grafts (Fig 3). We find sewing proximal to the arch vessels as described by Kusuhara [10] technically easier than sewing distally as described by Borst and colleagues [3] and Heineman and associates [4]. At this point the graft is unfolded and deaired, and the aortic cannula is placed in the graft. The proximal graft is then sewn to the ascending aorta. The patient is rewarmed and weaned from cardiopulmonary bypass. Follow-up computed tomography scans are performed before discharge to confirm absence of leakage at anastomotic sites and thrombosis of the excluded aneurysmal segment around the graft (Fig 3).
|
|
|
| Results |
|---|
|
|
|---|
|
|
|
One patient (number 14) was dialysis dependent preoperatively. Renal failure developed postoperatively in 4 (28%) patients; this resolved in 2 patients and the other 2 patients eventually died of multiple organ failure. Five patients (35%) required tracheostomy. One patient eventually required a DDD pacemaker. The first patient required reoperation for bleeding. Length of stay (LOS) after the operation ranged from 8 to 77 days with a mean of 31 days. However, 4 patients were discharged home after reasonably short stays. There were no perioperative deaths; 2 patients (14%) died in hospital. Both hospital deaths were from multiple organ failure; 1 of these was the patient (number 10) who had sustained a brainstem stroke.
Follow-up ranged from 5 to 54 months (Table 4). Seven patients are alive and doing well, although some had prolonged recovery times. One patient was paralyzed but states he is otherwise doing well. Another patient is alive but complains of balance difficulties. There were 3 late deaths at 5, 14, and 28 months after surgery1 of pneumonia and 2 of unknown etiology. In this elderly patient population with complex and extensive aortic disease, 50% had excellent results; 14% had acceptable results. There were 2 (14%) hospital deaths and 3 (21%) late deaths.
|
| Comment |
|---|
|
|
|---|
The second operation itself carries significant risk for morbidity and mortality. Heinemann and associates [4] reported paraplegia in 3 of 24 patients (12.5%) undergoing downstream procedures but no deaths. Williams and coworkers [9] report a 3% to 10% risk of a spinal cord injury in descending aortic aneurysms. Svensson and colleagues [7] reported a 5% mortality for the second-stage procedure. Furthermore, in an era of cost containment there is a significant savings by avoiding a second operation.
Accordingly, we have developed a single-stage transmediastinal approach for patients with ascending, arch, and descending aneurysms. We consider all patients with aneurysms of their ascending, arch, and descending thoracic aorta who traditionally would be treated with an elephant trunk approach and who have descending aneurysms that taper to a normal caliber aorta before the level of the diaphragm to be candidates for this procedure. The decision to proceed with a single-stage operation is made based on technical considerations (extent and size of the aneurysm at the level of the diaphragm). The size of the graft was typically that of the descending aorta, although in patient 9 a 28-mm graft was sewn into a slightly larger 33-mm descending aorta. We advocate consideration of this operation for all patients despite comorbidities as the single-stage approach assures completion at a risk at or less than that of a staged approach.
There are potential pitfalls with a one-stage exclusion technique including the theoretically increased risk of paralysis incurred by not reimplanting the spinal arteries and the potential for later dilation of the aneurysm around the graft if collateral vessels do not thrombose. However, in this small series computed tomography scans before discharge have shown thrombosis of the aneurysms in all patients.
Borst and coworkers [5] have previously described leaving a long distal elephant trunk in a patient with a descending aneurysm who underwent coronary bypass grafting for unstable angina. In this patient there was no ascending or arch component and the graft was not secured distally; the large descending aneurysm subsequently thrombosed around the graft without sequelae. The use of a long distal elephant trunk in acute aortic dissection of the descending aorta has also been reported by Buffolo and coworkers [11]; the mortality rate was 15% and the complication rate was 60%. In contrast to acute dissection, patients with aneurysmal disease usually have mural thromboses, which theoretically may lead to improved development of collaterals and thus preserved spinal artery flow; because of this, a long elephant trunk may not be ideal for cases of dissection. However, Crawford and associates [12] and Svensson [13] have noted postoperative paraplegia in patients with aneurysms who had long elephant trunk segments.
The Stanford University group has described endovascular stenting of descending thoracic aortic aneurysms [14, 15]. Before the procedure aortography is performed to delineate intercostal, visceral, and arch vessel anatomy. A stent graft is then placed through a cut-down on the femoral artery or retroperitoneal aorta. This groups most recently reported series of 103 patients revealed a mortality rate of 9%, a stroke rate of 7%, and a paraplegia rate of 3%; 5 patients required surgical intervention [15]. Complete thrombosis of the aneurysms was eventually achieved in 86% of patients. Although they had no late ruptures after stent graft placement, it has been reported [16]. The major reason for incomplete thrombosis around the stent grafts was attributed to perigraft leaks or "endoleaks" found in 24% of their patients. That should not be seen in the transmediastinal approach as the graft is sutured into position. None of our patients has had late rupture from intercostal vessels or from endoleaks.
The concern for neurologic sequelae with transmediastinal single-stage repair of ascending, arch, and descending aneurysms has been mitigated to some degree by the Stanford stent experience, as they report only a 3% paraplegia incidence after stent grafting of the descending thoracic aorta [15]. However, we did see neurologic deficits in 2 of our 14 patients. Of note, 1 of our patients (number 13) had undergone a previous aortobiiliac repair for an abdominal aortic aneurysm, which when combined with the thoracic aorta replacement may have left him with inadequate spinal perfusion. Of the 3 patients with paraplegia in the Stanford stent series, 1 had undergone an aortobifemoral bypass [15].
Although it was not performed in this series it may be necessary that all patients undergoing single-stage transmediastinal repair undergo thoracic aortic arteriography to assure that no major spinal arterial compromise will occur with graft exclusion. The greatest contribution of blood supply to the anterior spinal artery of the spinal cord comes from the artery of Adamkiewicz, which arises from the collateral network of intercostal vessels between T9 and T12 in approximately 70% of patients. Williams and colleagues [9] performed selective arteriography in 47 patients with extensive thoracoabdominal aneurysms to identify this vessel but they were only able to localize it 55% of the time.
Minale and colleagues [17] have also described replacement of the entire thoracic aorta in a single-stage operation in 12 patients using a bilateral thoracotomy technique in 7 patients and a sternotomy in 5. They had 2 perioperative deaths. Interestingly they did not reimplant intercostals and in fact oversewed them. They had no spinal cord injury and postulated that profound hypothermia had a protective effect. Massimo and associates [18] have described single-stage replacement of the entire aorta from the aortic valve to the iliac bifurcation. Using both a median sternotomy and a thoracoabdominal incision under deep hypothermia, this operation was performed in 21 patients with combined thoracic and abdominal emergencies. There were 3 deaths in the first month, for a mortality rate of 14%. They had neurologic deficits in 3 patients (14%); however, in contrast to our experience their deficits were all reversible. Of note, all 3 of these patients did have intercostal reimplantation. Our mortality of 14% compares favorably with these reports and with the literature if one were to combine the mortality associated with both stages of the elephant trunk procedure [4, 7, 8]. Even though our overall morbidity was high in this small series, we believe that with experience the transmediastinal approach through a standard median sternotomy will prove to be the least morbid of the single-stage techniques.
Our overall circulatory arrest times (mean 72 minutes) were longer than expected with a standard elephant trunk procedure and may have contributed to the development of multiple organ failure in 3 patients, 2 of whom died. Svensson and colleagues [7] have shown the risk of stroke increases with the length of circulatory arrest. Despite long circulatory arrest times, we had only 1 brainstem stroke, in a patient who had replacement of all her arch vessels under both circulatory arrest and isolated antegrade perfusion. We attribute the increased circulatory arrest times to a multitude of factors including proper placement and alignment of the descending graft and closure of the descending aorta through the posterior pericardium.
In a technique similar to our described transmediastinal aortic replacement, the Stanford group has performed initial elephant trunk repair of an ascending and arch aortic aneurysm through a median sternotomy followed by stent exclusion of a descending aneurysm in a patient with a forced expiratory volume in 1 second of 1.13. The patient avoided a potentially morbid thoracotomy, had no neurologic compromise, and the descending aneurysm thrombosed around the graft [19]. However, the Stanford group later reported 3 cases of stent grafting after ascending repair, and 1 patient needed emergency repair of the descending aorta, which ruptured during placement of a stent graft [14].
With transmediastinal aortic replacement the morbidity and cost of a second surgical or stenting procedure is obviated. Furthermore, no patients are left with untreated descending aneurysms vulnerable to rupture. Therefore, in our institution single-stage transmediastinal replacement of the thoracic aorta is considered for all patients with ascending, arch, and descending aneurysms that have tapering of the descending aneurysm at the level of the diaphragm. With increased experience we believe the morbidity and mortality associated with this procedure will decrease, making it the procedure of choice in our institution for these complex and technically demanding cases.
| Discussion |
|---|
|
|
|---|
DR BEAVER : Thank you for your comments. In fact, when we do descending thoracic aneurysms, we do use the techniques of Dr Safi (distal femoral perfusion and spinal CSF drainage). The approach I am presenting is simply to treat that subset of patients that have ascending arch and descending aneurysms and to address the problem of patients not being completely treated. I would submit that if you only do the ascending or first stage of an elephant trunk procedure and dont complete the second stage, you havent served that patient population.
| References |
|---|
|
|
|---|
This article has been cited by other articles:
![]() |
R. Di Bartolomeo, L. Di Marco, A. Armaro, D. Marsilli, A. Leone, E. Pilato, and D. Pacini Treatment of complex disease of the thoracic aorta: the frozen elephant trunk technique with the E-vita open prosthesis Eur. J. Cardiothorac. Surg., April 1, 2009; 35(4): 671 - 676. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Kim, T. D. Martin, W. A. Lee, P. J. Hess Jr., C. T. Klodell, C. G. Tribble, R. J. Feezor, and T. M. Beaver Evolution in the management of the total thoracic aorta. J. Thorac. Cardiovasc. Surg., March 1, 2009; 137(3): 627 - 634. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Okamoto, M. Matsumoto, and H. Inoue Single-stage repair of extended thoracic aortic aneurysm Interactive CardioVascular and Thoracic Surgery, March 1, 2009; 8(3): 377 - 378. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. X. Mosquera, V. Campos, M. Marini, J. V. Valle, I. Cao, D. Gulias, and A. Juffe Hybrid Procedure for Proximal Arch and Descending Aortic Aneurysms Ann. Thorac. Surg., December 1, 2008; 86(6): 1989 - 1991. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. D. Etz, K. A. Plestis, F. A. Kari, M. Luehr, C. A. Bodian, D. Spielvogel, and R. B. Griepp Staged repair of thoracic and thoracoabdominal aortic aneurysms using the elephant trunk technique: a consecutive series of 215 first stage and 120 complete repairs Eur. J. Cardiothorac. Surg., September 1, 2008; 34(3): 605 - 615. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Karck and H. Kamiya Progress of the treatment for extended aortic aneurysms; is the frozen elephant trunk technique the next standard in the treatment of complex aortic disease including the arch? Eur. J. Cardiothorac. Surg., June 1, 2008; 33(6): 1007 - 1013. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Kuhn, O. E. Teebken, J. Weidemann, M. Karck, M. Pichlmaier, and A. Haverich Surgical treatment of an aneurysm involving ascending aorta, aortic arch, and a rupture of a descending aortic aneurysm 26 years following acute type A aortic dissection J. Thorac. Cardiovasc. Surg., January 1, 2006; 131(1): 235 - 236. [Full Text] [PDF] |
||||
![]() |
H. Tanaka, T. Yamashita, K. Okada, and Y. Okita Successful surgery in a patient with a rupture of descending aorta complicated by acute type A aortic dissection through left-sided thoracotomy Interactive CardioVascular and Thoracic Surgery, April 1, 2005; 4(2): 116 - 117. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Kuniyoshi, K. Koja, K. Miyagi, T. Uezu, S. Yamashiro, and K. Arakaki The Prevention of Nerve Injury in Aortic Arch Aneurysmal Surgery Asian Cardiovasc Thorac Ann, December 1, 2004; 12(4): 374 - 375. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. M. Janelle, C. T. Klodell, and T. D. Martin Other Potential Solutions to Facilitate Thoracoabdominal Aortic Aneurysm Repair When Uncontrolled Hemorrhage Develops at the Subclavian Clamp Site Anesth. Analg., February 1, 2004; 98(2): 555 - 555. [Full Text] [PDF] |
||||
![]() |
Y. Takahara, K. Mogi, M. Sakurai, and H. Nishida Total aortic arch grafting via median sternotomy using integrated antegrade cerebral perfusion Ann. Thorac. Surg., November 1, 2003; 76(5): 1485 - 1489. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Pocar and F. Donatelli Median sternotomy for combined cardiac and descending thoracic aortic operation Ann. Thorac. Surg., December 1, 2002; 74(6): 2226 - 2227. [Full Text] [PDF] |
||||
![]() |
N. T. Kouchoukos, P. Masetti, and C. K. Rokkas Single-stage replacement of the thoracic aorta Ann. Thorac. Surg., October 1, 2002; 74(4): 1292 - 1292. [Full Text] [PDF] |
||||
![]() |
T. M. Beaver and T. D. Martin Reply Ann. Thorac. Surg., October 1, 2002; 74(4): 1293 - 1293. [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |