ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Wolfgang B. Hemmer
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hemmer, W. B.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Hemmer, W. B.
Related Collections
Right arrow Valve disease
Right arrowRelated Article

Ann Thorac Surg 2001;71:761
© 2001 The Society of Thoracic Surgeons


Correspondence

Leaflet escape in a Tekna valve in aortic position: reply

Wolfgang B. Hemmer, MDa

a Sana Herzchirurgische Klinik, Herdweg 2, D-70174 Stuttgart, Germany

To the Editor

This case study by Christiansen and associates reports on yet another incidence of leaflet escape in a Tekna valve prosthesis. The accompanying figure clearly shows a near-central fracture of a leaflet similar to that which we [1] originally described of the same prosthesis type but in the mitral position.

The investigation in our case showed local loss of pyrolytic carbon. The second case that we described was shown to have a fracture in the area of the pivot balls, which was reported for the original Duromedics prosthesis fracture.

It is not yet clear whether the investigation into the cause for this further report of a leaflet fracture in a Tekna prosthesis will provide any additional information. What is exceptional in this case report though is the implantation site at which this leaflet escape occurred. Leaflet escape is more often described in the mitral position than the aortic because of the greater pressure gradients and subsequent mechanical stresses of the mitral valve as compared with the aortic valve. This was the case in our report and also in earlier reports [1].

The clinician is unable to draw any firm conclusions with regard to the use and handling of Tekna prostheses from isolated reports. It is instead the responsibility of the company that manufactures these valve prostheses to provide adequate registration of all reports of prosthesis malfunction, to investigate the causes thereof, and in the case of abnormal performance to make these facts known to the surgeon and patients.

References

  1. Hemmer W.B., Doss M., Hannekum A., Kapfer X. Leaflet escape in a Tekna and an original Duromedics bileaflet valve. Ann Thorac Surg 2000;69:942-944.[Abstract/Free Full Text]

Related Article

Leaflet escape in a Tekna valve in aortic position
Stefan Christiansen, Hans H. Scheld, and Dieter Hammel
Ann. Thorac. Surg. 2001 71: 761. [Extract] [Full Text] [PDF]




This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Wolfgang B. Hemmer
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hemmer, W. B.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Hemmer, W. B.
Related Collections
Right arrow Valve disease
Right arrowRelated Article


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS