Ann Thorac Surg 1995;60:268-271
© 1995 The Society of Thoracic Surgeons
Departments of Cardiac and Thoracic Surgery, Radiology and Radiological Sciences, Divisions of Pulmonary and Critical Care Medicine, Pediatric Cardiology, and the Vanderbilt Transplant Center, Vanderbilt University Medical Center, Nashville, Tennessee
| Abstract |
|---|
|
|
|---|
Methods. To complement functional data provided by echocardiography, radionuclide ventriculography, and right heart catheterization, magnetic resonance imaging was used to assess right ventricular function in 5 single- lung transplant recipients with preoperative pulmonary hypertension and right ventricular dysfunction (right ventricular ejection fraction, 0.21 ± 0.09). The right and left ventricular mass, ejection fraction, and mass ratio (left ventricular mass/right ventricular mass) were calculated from the magnetic resonance images.
Results. The mean pulmonary artery pressure fell from 72 ± 18 to 21 ± 8 mm Hg after transplantation. At 3 months after transplantation both the left ventricular and right ventricular ejection fractions approached normal values, as shown by both radionuclide ventriculography and magnetic resonance imaging, but the right ventricular mass remained abnormally high with slightly low mass ratios. By 1 year both the left ventricular and right ventricular masses had regressed to normal with near-normal mass ratios.
Conclusions. Right ventricular performance returns to nearly normal early after transplantation, but the right ventricular mass regresses over a more prolonged time. Cine magnetic resonance imaging provides a noninvasive means of assessing changes in right ventricular function and mass after lung transplantation.
| Introduction |
|---|
|
|
|---|
We report our experience with cine magnetic resonance imaging (MRI), which was used to complement traditional imaging techniques in the documentation of changes in right ventricular function and mass after single-lung transplantation in 5 patients with severe pulmonary hypertension. These patients displayed pronounced right ventricular dysfunction preoperatively; their response to the right ventricular afterload reduction brought about by transplantation was prompt. The effects of the dramatic decrease in pulmonary artery pressure and pulmonary vascular resistance on right ventricular mass and function were quantitated using cine MRI.
Gradient-echo cine MRI, or cine MRI, provides high-resolution images of any plane within the heart at a temporal resolution of 25 to 50 ms. Previous studies have shown that cine MRI is capable of providing quantitative information on the function of the left ventricle [1, 2]. The right ventricle, which is of greatest interest in patients with severe dysfunction secondary to pulmonary hypertension, has been difficult to evaluate using any of the traditional imaging methods because of its geometric structure and location within the chest cavity. Various methods, including right heart catheterization, echocardiography, and radionuclide scanning, have been used in attempts to characterize right ventricular function. The tomographic capability of MRI overcomes many of the limitations of these more conventional methods in imaging the right ventricle [3--6].
| Material and Methods |
|---|
|
|
|---|
|
In all patients single-lung transplantation was performed using partial cardiopulmonary bypass. Femoral artery and right atrial cannulation was used in 2; aorta and right atrial cannulation in 2; and femoral artery and femoral vein cannulation in 1. Bronchial anastomoses were performed using interrupted absorbable sutures, and four of the five anastomoses were wrapped with an omental pedicle. The total ischemic time was 165 ± 32 minutes. Patients were extubated at 6 ± 3 days (range, 1 to 23 days) postoperatively.
Cine MRI was performed in the short-axis view in contiguous 7-mm slices from the atrioventricular valve plane to the apex. All imaging was performed on a Siemens SP4000 1.5T scanner (Siemens Medical Systems, Iselin, NJ). The temporal resolution was 50 ms. All acquisitions were electrocardiography-triggered. Image analysis consisted of manual definition of the endocardial and epicardial borders of both the right and left ventricles at end-diastole and of definition of the endocardial borders at end-systole. The end-diastolic image was considered the first image in each cine loop (acquired just after the R-wave trigger), and the end-systolic image was determined visually as the image in the cine loop with the smallest blood volume. The image analysis was performed using an independent three-dimensional image-processing workstation (MaxiView; Dimensional Medicine, Minnetonka, MN). The volumes contained within the epicardial and endocardial borders were calculated by integrating over all slices. Myocardial mass was calculated as the difference between the volumes contained within the epicardial and endocardial borders in each ventricle at end-diastole multiplied by an assumed density of 1.05 g/cm3. Stroke volume was calculated as the difference between endocardial volumes at end-diastole and end-systole. Ejection fraction was calculated as the stroke volume divided by the end-diastolic volume. This analytic method was validated previously in our laboratory in dogs by correlating MRI findings with anatomic abnormalities [5].
| Results |
|---|
|
|
|---|
As expected, the pulmonary vascular resistance decreased significantly from a mean of 1607 ± 876 dynes s/cm5 preoperatively (range, 509 to 2800 dynes s/cm5) to 219 ± 124 dynes s/cm5 postoperatively (range, 49 to 400 dynes s/cm5), remaining normal at 1 year. The transpulmonary gradient declined from 66 ± 18 mm Hg preoperatively to 11 ± 4 mm Hg at 2 months and was 15 ± 6 mm Hg at 1 year.
The cardiac index, measured at rest by the thermodilution method by means of right heart catheterization, increased in 4 patients and was unchanged in the fifth patient. The mean cardiac index preoperatively was 2.3 ± 0.42 L min-1 m-2 and increased postoperatively to 3.3 ± 0.50 L min-1 m-2.
The ejection fraction of both the right and left ventricles was obtained by radionuclide ventriculography in 4 patients preoperatively and in all 5 patients postoperatively. The right ventricular ejection fraction increased dramatically from 0.21 ± 0.09 preoperatively (range, 0.05 to 0.28) to 0.47 ± 0.10 postoperatively at 1 month (range, 0.35 to 0.55). The left ventricular ejection fraction did not change substantially with transplantation (0.55 preoperatively and 0.56 postoperatively).
The tomographically derived ejection fractions determined by cine MRI are shown in Table 2
. The right ventricular ejection fraction was normal at 3 months and remained normal at 1 year. In contrast, the right ventricular mass remained markedly high at 79 ± 11 g (normal, 49 ± 12 g) at 3 months and did not decline to normal values until the 1-year study. The left ventricular mass remained in the normal range throughout the postoperative evaluation period. The ratio of the left ventricular mass to the right ventricular mass was below normal at 3 months but had normalized by the time of the 1-year study.
|
The echocardiographically determined septal thickness decreased from 1.3 ± 0.1 cm preoperatively to 0.9 ± 0.1 cm at 3 months and 1 year. The preoperative left ventricular end-diastolic dimension (2.7 ± 0.2 cm) was well below normal (3.5 to 5.6 cm); it increased to a normal dimension at 3 months (4.4 ± 0.2 cm) and remained normal at 1 year. The increase in the left ventricular end-diastolic dimension is consistent with the restoration of normal left ventricular geometry. The left ventricle, which had an abnormal D shape with bowing of the septum into the left ventricular cavity before transplantation, returned to normal postoperatively.
| Comment |
|---|
|
|
|---|
The right ventricular ejection fraction improved significantly, as shown by both radionuclide ventriculography and MRI, whereas the left ventricular ejection fraction remained normal. The cardiac index increased significantly in response to the reduction in the pulmonary vascular resistance to normal. Most of the increase in cardiac output is delivered to the transplanted lung because of its lower vascular resistance. In patients who undergo transplantation for pulmonary hypertension, the grafted lung typically receives 85% or more of the resultant cardiac output, as measured by radionuclide perfusion scanning.
Dysfunction of the right ventricle is an important problem in both children and adults after the transplantation of thoracic organs. The potential clinical impact of a noninvasive, reproducible means of assessing right ventricular function is substantial. Right ventricular dysfunction may develop in patients with chronic right ventricular pressure and volume overload resulting from pulmonary hypertension or from right ventricular outflow tract obstruction stemming from any cause. With improved understanding of the adaptation of the right ventricle to overload, the optimal therapy (eg, single-lung versus heart-lung transplantation versus afterload reduction) for individual patients could be determined. Few methods are currently available for the noninvasive, serial assessment of right ventricular function. Magnetic resonance imaging has the ability to quantitate right ventricular function without the many limitations inherent in other imaging methods.
The only other technique that has been shown to yield accurate estimates of both right and left ventricular mass has been ultrafast computed tomography [7]. Although MRI is currently more expensive and time-consuming than ultrafast computed tomography, it has wider applicability. Ultrafast computed tomography is not available in many centers, whereas MRI has generally become widely available. Moreover, MRI does not require the use of contrast agents and the patient is not exposed to ionizing radiation.
Because many patients with pulmonary hypertension eventually succumb to progressive right ventricular failure, transplantation of a single lung or reduction in the right ventricular afterload achieved by other means can ameliorate the cause of the right ventricular failure. This study demonstrates the regression in right ventricular function and mass abnormalities that occurs in these patients after lung transplantation. It has yet to be shown what degree of right ventricular dysfunction, if any, is not reversible when afterload is reduced. Cine MRI is a method that has the potential for accomplishing an accurate serial assessment of right ventricular mass and function.
In conclusion, right ventricular function returns to normal early in patients with pulmonary hypertension who undergo single-lung transplantation, whereas right ventricular mass regresses more slowly. As an adjunct to more traditional imaging methods, cine MRI permits the quantitation of right ventricular mass and volume without geometric assumptions and should be useful for further defining the adaptive properties of the right ventricle.
| Acknowledgments |
|---|
|
|
|---|
We thank Ms Victoria L. Morgan for help with analysis of the magnetic resonance images.
| Footnotes |
|---|
|
|
|---|
Address reprint requests to Dr Frist, c/o Daryl P. Pearlstein, 344 Village at Vanderbilt, Nashville, TN 37212.
| References |
|---|
|
|
|---|
Related Article
This article has been cited by other articles:
![]() |
L. E. R. McLure and A. J. Peacock Cardiac magnetic resonance imaging for the assessment of the heart and pulmonary circulation in pulmonary hypertension Eur. Respir. J., June 1, 2009; 33(6): 1454 - 1466. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.-T. Kasimir, G. Seebacher, P. Jaksch, G. Winkler, K. Schmid, G. M. Marta, P. Simon, and W. Klepetko Reverse cardiac remodelling in patients with primary pulmonary hypertension after isolated lung transplantation Eur. J. Cardiothorac. Surg., October 1, 2004; 26(4): 776 - 781. [Abstract] [Full Text] [PDF] |
||||
![]() |
T.S. Saba, J. Foster, M. Cockburn, M. Cowan, and A.J. Peacock Ventricular mass index using magnetic resonance imaging accurately estimates pulmonary artery pressure Eur. Respir. J., December 1, 2002; 20(6): 1519 - 1524. [Abstract] [Full Text] [PDF] |
||||
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |