ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Francis D. Pagani
James W. Long
Walter P. Dembitsky
Lyle D. Joyce
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pagani, F. D.
Right arrow Articles by Miller, L. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pagani, F. D.
Right arrow Articles by Miller, L. W.
Related Collections
Right arrow Mechanical Circulatory Assistance
Right arrowRelated Article

Ann Thorac Surg 2006;82:1413-1418
© 2006 The Society of Thoracic Surgeons


Original Articles: Cardiovascular

Improved Mechanical Reliability of the HeartMate XVE Left Ventricular Assist System

Francis D. Pagani, MD, PhDa,*, James W. Long, MD, PhDb, Walter P. Dembitsky, MDc, Lyle D. Joyce, MD, PhDd, Leslie W. Miller, MDe

a Section of Cardiac Surgery, University of Michigan Health System, Ann Arbor, Michigan
b Utah Artificial Heart Program, University of Utah School of Medicine and LDS Hospital, Salt Lake City, Utah
c Division of Cardiovascular Surgery, Sharp Memorial Hospital, San Diego, California
d Division of Cardiothoracic Surgery, University of Minnesota, Minneapolis, Minnesota
e Cardiovascular Division, University of Minnesota, Minneapolis, Minnesota

Accepted for publication April 19, 2006.

* Address correspondence to Dr Pagani, Section of Cardiac Surgery, 2124 Taubman Center, Box 0348, 1500 E. Medical Center Dr, Ann Arbor, MI 48109 (Email: fpagani{at}umich.edu).

BACKGROUND: The HeartMate XVE left ventricular assist device is a valuable treatment option for patients with end-stage heart failure. During the past several years, the XVE has undergone a series of design enhancements to improve reliability. We compared the reliability of the two most recent design iterations of the XVE pump (stitch modification to the inflow valve assembly and new inflow valve housing redesign) to the earlier VE version.

METHODS: A retrospective evaluation of device reliability was performed for 268 devices implanted in 245 patients (VE: n = 167 devices, 147 patients, implant dates October 16, 1998, to December 19, 2003; XVE: n = 101 devices, 98 patients, implant dates August 1, 2002, to April 14, 2004).

RESULTS: Median duration of device support for the VE and XVE was 159 days (range, 0 to 1,206 days) and 229 days (range, 0 to 693 days), respectively (p = 0.495). Significantly fewer major device malfunctions occurred within the XVE group as compared with the VE group (6 versus 36, respectively; p = 0.0003). The number of major device malfunctions per patient-year of support for inflow valve dysfunction, bearing wear, and other failures for the VE and XVE were 0.2 versus 0.04 (p = 0.006), 0.16 versus 0.01 (p = 0.005), and 0.06 versus 0.04 (p = 1.000), respectively. The freedom from major device malfunction at 1 year was 76% ± 6% for the VE and 97% ± 2% for the XVE device (p < 0.001). The freedom from death as a result of major device malfunction at 1 year was 97% ± 2% for the VE and 98% ± 2% for the XVE (p = 0.698).

CONCLUSIONS: Design enhancements to the HeartMate XVE have significantly reduced the incidence of major device malfunctions compared with the earlier VE model because of a reduction in failure modes from bearing wear and inlet valve dysfunction. Further follow-up is necessary to establish the long-term durability of the most recent XVE pump version.


Related Article

Invited commentary
Craig H. Selzman
Ann. Thorac. Surg. 2006 82: 1418-1419. [Extract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
S. Osaki, N. M. Edwards, M. Velez, M. R. Johnson, M. A. Murray, J. A. Hoffmann, and T. Kohmoto
Improved survival in patients with ventricular assist device therapy: the University of Wisconsin experience.
Eur. J. Cardiothorac. Surg., August 1, 2008; 34(2): 281 - 288.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. H. Selzman
Invited commentary.
Ann. Thorac. Surg., October 1, 2006; 82(4): 1418 - 1419.