Right arrow Author home page(s):
Ruyun Jin
Gary L. Grunkemeier
Donald N. Ross
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Athanasiou, T.
Right arrow Articles by Ross, D. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Athanasiou, T.
Right arrow Articles by Ross, D. N.
Related Collections
Right arrow Valve disease
Right arrowRelated Article

Ann Thorac Surg 2006;81:1578-1585
© 2006 The Society of Thoracic Surgeons


Original article: Cardiovascular

Homograft Implantation Techniques in the Aortic Position: To Preserve or Replace the Aortic Root?

Thanos Athanasiou, MD, PhD a , * , Catherine Jones, MBBS a , Ruyun Jin, MD b , Gary L. Grunkemeier, PhD b , Donald N. Ross, FRCS a

a Imperial College of Science, Technology and Medicine, Department of Surgical Oncology and Technology, St. Mary's Hospital, London, United Kingdom
b Providence Health System, Portland, Oregon

Accepted for publication December 13, 2005.

* Address correspondence to Dr Athanasiou, 70 St Olaf's Road, Fulham, London SW6 7DN, United Kingdom (Email: tathan5253{at}aol.com).

BACKGROUND: One determinant of durability of the homograft in the aortic position is the implantation technique. This study uses meta-analytical techniques to evaluate the differences in early and long-term outcomes of patients undergoing aortic homograft implantation with either a root replacement or a root preserving technique.

METHODS: A systematic review of the literature (1965–2005) reporting results after homograft implantation in the aortic position with emphasis in the implantation technique was performed. Random and fixed-effects models were used. Cumulative and influential meta-analysis, graphic exploration, and sensitivity analysis were carried out to explain the heterogeneity between studies and to investigate potential publication bias.

RESULTS: Eleven studies were included. None of the studies was randomized. There was no significant difference in early mortality between root replacement and root preserving groups (odds ratio = 2.57 with 95% confidence interval [CI] 0.68–9.72 in random-effects model) and the root replacement group had a significantly lower rate of reoperation during long-term follow-up (hazard ratio = 0.55 with 95% CI 0.38–0.80 in random-effects model). Subgroup analysis focusing on patients having the subcoronary technique for homograft implantation showed similar results. Significant heterogeneity between studies can be detected. No publication bias was found.

CONCLUSIONS: There was no significant difference in early mortality between root replacement and root preserving groups. However, the root replacement technique group had a significantly lower rate of reoperation during long-term follow-up. Excluding outliers identified in a funnel plot reduced the heterogeneity and reached a similar conclusion.


Related Article

Invited commentary
Tirone E. David
Ann. Thorac. Surg. 2006 81: 1585-1586. [Extract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
Eur Heart JHome page
A. Ali, Y. Abu-Omar, A. Patel, Z. Ali, A. Y. Sheikh, A. Akhtar, A. Pavlovic, P. Theodorou, T. Athanasiou, and J. Pepper
Valve failure following homograft aortic valve replacement: does implantation technique have an effect?
Eur. Heart J., June 1, 2008; 29(11): 1454 - 1462.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
T. Athanasiou, A. Chow, C. Rao, O. Aziz, F. Siannis, A. Ali, A. Darzi, and F. Wells
Preservation of the mitral valve apparatus: evidence synthesis and critical reappraisal of surgical techniques
Eur. J. Cardiothorac. Surg., March 1, 2008; 33(3): 391 - 401.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J.-F. Avierinos, F. Thuny, V. Chalvignac, R. Giorgi, L. Tafanelli, J.-P. Casalta, D. Raoult, T. Mesana, F. Collart, D. Metras, et al.
Surgical Treatment of Active Aortic Endocarditis: Homografts Are Not the Cornerstone of Outcome
Ann. Thorac. Surg., December 1, 2007; 84(6): 1935 - 1942.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J. J.M. Takkenberg, L. M.A. Klieverik, J. A. Bekkers, A. P. Kappetein, J. W. Roos, M. J.C. Eijkemans, and A. J.J.C. Bogers
Allografts for aortic valve or root replacement: insights from an 18-year single-center prospective follow-up study
Eur. J. Cardiothorac. Surg., May 1, 2007; 31(5): 851 - 859.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
R.-U. Kuehnel, U. A. Stock, M. O. Wendt, I. Degenkolbe, U. Jainski, M. Hartrumpf, M. Pohl, and J. M. Albes
Physiological function of stentless aortic valves is altered by trimming and removal of aortic wall components
Interactive CardioVascular and Thoracic Surgery, April 1, 2007; 6(2): 182 - 187.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. E. David
Invited commentary.
Ann. Thorac. Surg., May 1, 2006; 81(5): 1585 - 1586.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2006 by The Society of Thoracic Surgeons.