ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Martin Misfeld
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Misfeld, M.
Right arrow Articles by Sievers, H.-H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Misfeld, M.
Right arrow Articles by Sievers, H.-H.
Related Collections
Right arrow Great vessels
Right arrowRelated Article

Ann Thorac Surg 2004;78:1060-1063
© 2004 The Society of Thoracic Surgeons


New technology

A novel, form-stable, anatomically curved vascular prosthesis for replacement of the thoracic aorta

Martin Misfeld, MDa, Michael Scharfschwerdta, Hans-H. Sievers, MDa,*

a Clinic of Cardiac Surgery, University Clinic of Schleswig-Holstein, Campus Lübeck, Lübeck, Germany

Accepted for publication September 22, 2003.

* Address reprint requests to Prof Dr Sievers, Clinic of Cardiac Surgery, University Clinic of Schleswig-Holstein, Campus Lübeck, Ratzeburger Allee 160, 23538 Lübeck, Germany
herzchir{at}medinf.mu-luebeck.de

Abstract

PURPOSE: Current replacement of the thoracic aorta performed with straight vascular prostheses may cause kinking, potentially affecting hemodynamics and promoting vortices and thrombus formation. A novel vascular prosthesis, resistant to pressure-related shape deformation, was designed to imitate the curved anatomy of the thoracic aorta.

DESCRIPTION: A woven velour prosthesis was trimmed with cross-sutures along a marked line, resulting in a curved-shaped anatomic form, and was compared with conventional straight and thermally fixed curved grafts. The vascular prostheses were fixed at both ends at various base distances (8, 10, 12, 14, and 16 cm) and pressurized. To imitate the neck vessels an abutment was fixed at the upper convexity of the grafts. Radius of curvature or depth of kinking was measured at different pressures (100, 125, and 150 mm Hg). Pressure gradients and flow profiles were further analyzed in an aortic arch glass model.

EVALUATION: When pressurized the straight and the thermally fixed protheses showed double kinking before and behind the abutment at all pressures and distances. Kinking depth increased with increasing pressure and less base distance. Transkinking pressure gradients increased with the degree of kinking. In a glass model flow profiles showed postkinking turbulences and vortex formation. The newly designed vascular prosthesis showed no kinking and remained form stable at all test conditions.

CONCLUSIONS: This novel curved vascular prosthesis for replacement of the thoracic aorta demonstrates form stability compared with conventional straight and thermally fixed vascular prostheses in an aortic arch model, with smaller pressure gradients and flow disturbances.


Related Article

Invited commentary
Lars G. Svensson
Ann. Thorac. Surg. 2004 78: 1063. [Extract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
ICVTSHome page
A. Salemi and G. B. Pettersson
Aortic arch reconstruction utilizing a simple reversed graft trimming technique
Interactive CardioVascular and Thoracic Surgery, June 1, 2006; 5(3): 247 - 248.