ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Tarek M. Aziz
Rasheed A.G. Saad
Marcello Migliore
Colin S. Campbell
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Aziz, T. M.
Right arrow Articles by Yonan, N. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Aziz, T. M.
Right arrow Articles by Yonan, N. A.
Related Collections
Right arrow Lung - transplantation
Right arrowRelated Article

Ann Thorac Surg 2002;73:1599-1604
© 2002 The Society of Thoracic Surgeons


Original article: general thoracic

Pulmonary vein gas analysis for assessing donor lung function

Tarek M. Aziz, FRCS*a, Ahmed El-Gamel, FRCSa, Rasheed A.G. Saad, MRCSa, Marcello Migliore, FETSa, Colin S. Campbell, FRCSa, Nizar A. Yonan, FRCSa

a Transplant Unit, Wythenshawe Hospital, Manchester, United Kingdom

Accepted for publication January 4, 2002.

* Address reprint requests to Mr Aziz, Cardiac Transplant Unit, Freeman Hospital, Freeman Road, High Heaton, Newcastle-upon-Tyne, NE 7 7DN United Kingdom
e-mail: tarekaziz55{at}hotmail.com

Background. Radial artery oxygenation (PaO2) is the standard method for assessing potential lung donors. This study was proposed to assess the use of pulmonary vein gases (PvO2) in selection of donor lung for transplantation.

Methods. We studied 170 lungs from 85 consecutive donors. Lungs were classified into group A, PaO2 and PvO2 > 300 mm Hg; group B, PaO2 < 300 mm Hg, and PvO2 > 300 mm Hg; and group C, PvO2 < 300 mm Hg.

Results. Lungs retrieved from group A and group B were used for transplantation. Allograft function, assessed by the arterial and alveolar oxygen tension ratio, was similar at 12 hours and at 24 hours after operation (0.69, 0.73, vs 0.70, 0.71, for groups A and B, respectively (p = 0.8, 0.7, respectively). Similar radiologic appearance was seen in both groups (p = 0.2). Median duration of intubation was also similar (p = 0.6). The 30-day mortality rate was 12% versus 11.3% (p = 0.8), and 1-year survival rate was 80% versus 82% (p = 0.8) for recipient received lungs from group A and B donors, respectively.

Conclusions. Selective pulmonary veins analysis gives an accurate assessment of individual gas exchange in comparison with arterial PaO2, identifying more potential donor lungs for transplantation.


Related Article

Invited commentary
John V. Conte
Ann. Thorac. Surg. 2002 73: 1604-1605. [Extract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
P. Botha, D. Trivedi, C. P. Searl, P. A. Corris, S. V.B. Schueler, and J. H. Dark
Differential Pulmonary Vein Gases Predict Primary Graft Dysfunction
Ann. Thorac. Surg., December 1, 2006; 82(6): 1998 - 2002.
[Abstract] [Full Text] [PDF]


Home page
Canadian J. AnesthesiaHome page
D. J. Kutsogiannis, G. Pagliarello, C. Doig, H. Ross, and S. D. Shemie
Medical management to optimize donor organ potential: review of the literature: [Traitement medical pour optimaliser le potentiel de don d'organe : une revue documentaire].
Can J Anesth, August 1, 2006; 53(8): 820 - 830.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 by The Society of Thoracic Surgeons.