a Department of Cardiothoracic and Vascular Surgery, University of Texas Medical School Houston, Houston, Texas
b Department of Anesthesia, University of Texas Medical School Houston, Houston, Texas
Accepted for publication March 13, 2009.
* Address correspondence to Dr Estrera, Suite 2850, 6400 Fannin St., Houston, TX 77030 (Email: anthony.l.estrera{at}uth.tmc.edu).
Presented at the Forty-fifth Annual Meeting of The Society of Thoracic Surgeons, San Francisco, CA, Jan 26–28, 2009.
Background: The benefit of cerebrospinal fluid (CSF) drainage during thoracic aortic repair has been established. Few studies, however, report management and safety of CSF drainage.
Methods: Between September 1992 and August 2007, 1,353 repairs of the thoracic aorta were performed, with 82% using CSF drainage. The CSF drainage was not used in cases of rupture, acute trauma, infection, or prior paraplegia. Thirty-one percent (76 of 246) of patients without CSF drainage were repaired prior to standardized use. All drains were inserted by cardiovascular anesthesia staff. Repairs were performed using distal aortic perfusion with heparinization. Early management involved free drainage to maintain CSF pressure less than10 mm Hg, but was later modified to limit CSF drainage unless neurologic deficit occurred.
Results: Cerebrospinal fluid drainage was technically achieved in 99.8% (1,105 of 1,107) of cases. The CSF catheter-related complications occurred in 1.5% (17 of 1,107) of patients. No spinal hematomas were observed. The CSF leaks with spinal headache, CSF leak without spinal headache, spinal headache, intracranial hemorrhage, catheter fracture, and meningitis occurred in 6 (0.54%), 1 (0.1%), 2 (0.2%), 5 (0.45%), 1 (0.1%), and 2 (0.2%) cases, respectively. Mortality from subdural hematoma was 40% (2 of 5), and from meningitis was 50% (1 of 2). Spinal headaches resolved with conservative management. All CSF leaks resolved, but 71% (5/7) required blood patches. Since implementation of a limited CSF drainage protocol, no subdural hematomas have been observed.
Conclusions: Cerebrospinal fluid drainage for thoracic aortic repairs can be performed safely with excellent technical success. Perioperative management of CSF drains requires diligent monitoring and judicious drainage. Standardizing CSF management may be beneficial.
This article has been cited by other articles:
![]() |
B. W. Ullery, G. J. Wang, D. Low, and A. T. Cheung Neurological Complications of Thoracic Endovascular Aortic Repair Seminars in Cardiothoracic and Vascular Anesthesia, December 1, 2011; 15(4): 123 - 140. [Abstract] [PDF] |
||||
![]() |
M. Field, J. Doolan, M. Safar, M. Kuduvalli, A. Oo, K. Mills, J. Kendall, and M. Desmond The safe use of spinal drains in thoracic aortic surgery Interact CardioVasc Thorac Surg, December 1, 2011; 13(6): 557 - 565. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. L. Estrera, R. Sheinbaum, C. C. Miller III, R. Harrison, and H. J. Safi Neuromonitor-guided repair of thoracoabdominal aortic aneurysms J. Thorac. Cardiovasc. Surg., December 1, 2010; 140(6_suppl): S131 - S135. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. A. Fedorow, M. C. Moon, W. A. C. Mutch, and H. P. Grocott Review Articles: Lumbar Cerebrospinal Fluid Drainage for Thoracoabdominal Aortic Surgery: Rationale and Practical Considerations for Management Anesth. Analg., July 1, 2010; 111(1): 46 - 58. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |