ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Ann Thorac Surg 2009;87:1914-1917. doi:10.1016/j.athoracsur.2009.01.054
© 2009 The Society of Thoracic Surgeons

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Sven Martens
Anton Moritz
Mirko Doss
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Martens, S.
Right arrow Articles by Doss, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Martens, S.
Right arrow Articles by Doss, M.
Related Collections
Right arrow Valve disease
Right arrowRelated Article


New Technology

Sutureless Aortic Valve Replacement With the 3f Enable Aortic Bioprosthesis

Sven Martens, MD*, Anja Ploss, MD, Sami Sirat, MD, Alexandra Miskovic, MD, Anton Moritz, MD, Mirko Doss, MD

Department of Thoracic and Cardiovascular Surgery, JW Goethe University Hospital, Frankfurt, Germany

Accepted for publication January 21, 2009.

* Address correspondence to Dr Martens, Department of Thoracic and Cardiovascular Surgery, JW Goethe University Hospital, Thoedor Stern Kai 7, Frankfurt, D-60590, Germany (Email: martens.herz{at}gmx.de).

Purpose: Important comorbid conditions in elderly patients referred for aortic valve replacement require alternative treatment options with possible reduction of the extracorporeal circuit time and reliable hemodynamic features. We report on clinical experiences with the sutureless, nitinol-stented 3f Enable (ATS Medical, Minneapolis, MN) aortic valve prosthesis in 32 patients.

Description: The procedure was performed using cardiopulmonary bypass with cardioplegic arrest. After resection of the stenotic aortic valve and debridement of the annulus, the valve was inserted and released. Mean age was 78 ± 3; mean logistic Euroscore was 13.7. Concomitant procedures were mitral valve and tricuspid valve repair (n = 1), coronary artery bypass graft (n = 9), and subvalvular myectomy (n = 3).

Evaluation: Implantation of the valve required 9 ± 5 minutes. Cardiopulmonary bypass and aortic cross-clamp time were 87 ± 16 and 55 ± 11 minutes for stand-alone procedures. Combined procedures required 126 ± 42 and 84 ± 28 minutes, respectively. Two patients were abandoned intraoperatively and converted to standard procedures due to misalignment of the valve. In the other 30 patients, no paravalvular leakage was detected. The transvalvular gradient at discharge was 9 ± 6 mm Hg (mean) and 18 ± 9 mm Hg (peak). Six months after surgery, gradients were 10 ± 4 mm Hg (mean) and 18 ± 6 mm Hg (peak).

Conclusions: Sutureless valve implantation is feasible and safe with the 3f Enable (ATS Medical) bioprosthesis. Reduction of cardiopulmonary bypass and aortic cross-clamp time seems to be possible with increasing experience. Hemodynamic data are promising with low gradients at discharge and after 6 months.


Related Article

Invited Commentary
George Magovern, Jr
Ann. Thorac. Surg. 2009 87: 1917-1918. [Extract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
Interact CardioVasc Thorac SurgHome page
M. Kalejs, R. Lacis, V. Kasyanov, I. Ozolanta, P. Abdel Sayed, P. Stradins, and L. K. von Segesser
Comparison of radial deformability of stent posts of different aortic bioprostheses
Interact CardioVasc Thorac Surg, February 1, 2013; 16(2): 129 - 133.
[Abstract] [Full Text] [PDF]


Home page
Interact CardioVasc Thorac SurgHome page
G. Concistre, A. Miceli, F. Chiaramonti, and M. Glauber
Delayed dislocation of a sutureless aortic bioprosthesis: the first case
Interact CardioVasc Thorac Surg, June 1, 2012; 14(6): 892 - 893.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. A. Folliguet, F. Laborde, K. Zannis, G. Ghorayeb, A. Haverich, and M. Shrestha
Sutureless Perceval Aortic Valve Replacement: Results of Two European Centers
Ann. Thorac. Surg., May 1, 2012; 93(5): 1483 - 1488.
[Abstract] [Full Text] [PDF]


Home page
Interact CardioVasc Thorac SurgHome page
A. H. Sepehripour, L. Harling, and T. Athanasiou
What are the current results of sutureless valves in high-risk aortic valve disease patients?
Interact CardioVasc Thorac Surg, May 1, 2012; 14(5): 615 - 621.
[Abstract] [Full Text] [PDF]


Home page
Interact CardioVasc Thorac SurgHome page
G. Concistre, P. Farneti, A. Miceli, and M. Glauber
Sutureless aortic bioprosthesis in severe aortic root calcification: an innovative approach
Interact CardioVasc Thorac Surg, May 1, 2012; 14(5): 670 - 672.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. Risteski, C. Adami, N. Papadopoulos, A. S. Sirat, A. Moritz, and M. Doss
Leaflet Replacement for Aortic Stenosis Using the 3f Stentless Aortic Bioprosthesis: Midterm Results
Ann. Thorac. Surg., April 1, 2012; 93(4): 1134 - 1140.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
W. Flameng, M.-C. Herregods, H. Hermans, G. Van der Mieren, M. Vercalsteren, G. Poortmans, J. Van Hemelrijck, and B. Meuris
Effect of sutureless implantation of the Perceval S aortic valve bioprosthesis on intraoperative and early postoperative outcomes
J. Thorac. Cardiovasc. Surg., December 1, 2011; 142(6): 1453 - 1457.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
E. Berreklouw, B. Koene, F. De Somer, S. Bouchez, K. Chiers, Y. Taeymans, and G. J. Van Nooten
Sutureless replacement of aortic valves with St Jude Medical mechanical valve prostheses and Nitinol attachment rings: Feasibility in long-term (90-day) pig experiments
J. Thorac. Cardiovasc. Surg., May 1, 2011; 141(5): 1231 - 1237.e1.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Garatti, F. Mori, F. Innocente, A. Canziani, P. Gagliardotto, E. Mossuto, T. Santoro, V. Montericcio, A. Frigiola, and L. Menicanti
Aortic Valve Replacement With 17-mm Mechanical Prostheses: Is Patient-Prosthesis Mismatch a Relevant Phenomenon?
Ann. Thorac. Surg., January 1, 2011; 91(1): 71 - 77.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
I. Breitenbach, G. Wimmer-Greinecker, L. A. Bockeria, J. Sadowski, C. Schmitz, B. Kapelak, K. Bartus, R. Muratov, and W. Harringer
Sutureless aortic valve replacement with the Trilogy Aortic Valve System: Multicenter experience
J. Thorac. Cardiovasc. Surg., October 1, 2010; 140(4): 878 - 884.e1.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
T. Aymard, A. Kadner, N. Walpoth, V. Gober, L. Englberger, M. Stalder, F. Eckstein, C. Zobrist, and T. Carrel
Clinical experience with the second-generation 3f Enable sutureless aortic valve prosthesis
J. Thorac. Cardiovasc. Surg., August 1, 2010; 140(2): 313 - 316.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. Magovern Jr
Invited Commentary
Ann. Thorac. Surg., June 1, 2009; 87(6): 1917 - 1918.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2009 by The Society of Thoracic Surgeons.