a Department of Cardiothoracic Sciences, Second University of Naples, Naples, Italy
b Department of Cardiovascular Surgery and Transplants, V. Monaldi Hospital, Naples, Italy
Accepted for publication September 4, 2008.
* Address correspondence to Dr Vicchio, Via Cassano 150, Naples, 80144, Italy (Email: marianovicchio{at}libero.it).
Background: Evaluation of the impact of prosthesis-patient mismatch (PPM) on long-term outcome and quality of life (QOL) in elderly patients who underwent implantation of small size bileaflet prostheses for aortic stenosis.
Methods: Between September 1988 and September 2006, 377 patients aged greater than 70 years underwent aortic valve replacement with a small size bileaflet prosthesis (17, 19, and 21 mm) in one Institution. The study population's survivors (345 patients) were divided into three groups according to the indexed effective orifice area (EOAI): Group A included patients with EOAI less than 0.60 cm2/m2; group B included patients with EOAI ranging between 0.61 and 0.84 cm2/m2; and group C included patients with EOAI 0.85 cm2/m2 or greater. Cumulative and comparative analyses of long-term outcomes and of left ventricular mass regression were performed. The QOL was evaluated with the 36-Item Short Form Health Survey (SF-36) questionnaire.
Results: Overall hospital mortality was 8.5% (32 patients). Group A included 33 patients (9.6%), group B 175 (50.7%), and group C 137 (39.7%). Actuarial survival was 88.8% ± 0.016 at 1 year, 82.1% ± 0.022 at 5 years, and 76.7% ± 0.032 at 10 years. No difference emerged among the three groups. A significant reduction in left ventricular mass was observed in all groups and in all patient subsets of prosthetic size. The scores obtained in the SF-36 test were similar in the three groups and significantly higher than those of the general population (p < 0.001 in all domains).
Conclusions: Incidence of severe PPM is low after aortic valve replacement. Presence of severe or moderate PPM, did not influence long-term outcome, left ventricular mass regression and QOL in a population of septuagenarians.
Related Article
Ann. Thorac. Surg. 2008 86: 1798.
This article has been cited by other articles:
![]() |
M. Vicchio, M. De Feo, and M. Cotrufo Prosthesis-patient mismatch does not affect survival and quality of life in the elderly having bileaflet prostheses implant J. Thorac. Cardiovasc. Surg., September 1, 2009; 138(3): 787 - 788. [Full Text] [PDF] |
||||
![]() |
M. Vicchio, A. Della Corte, M. De Feo, and M. Cotrufo Reply Ann. Thorac. Surg., September 1, 2009; 88(3): 1050 - 1051. [Full Text] [PDF] |
||||
![]() |
A. Kulik, N. T. Kouchoukos, and M. Ruel Avoiding prosthesis-patient mismatch in the elderly: options other than mechanical prostheses. Ann. Thorac. Surg., September 1, 2009; 88(3): 1049 - 1050. [Full Text] [PDF] |
||||
![]() |
M. Vicchio, A. Della Corte, M. De Feo, and M. Cotrufo Reply Ann. Thorac. Surg., August 1, 2009; 88(2): 710 - 710. [Full Text] [PDF] |
||||
![]() |
H. Gasparovic Prosthesis-patient mismatch in the elderly. Ann. Thorac. Surg., August 1, 2009; 88(2): 709 - 710. [Full Text] [PDF] |
||||
![]() |
M. K. Banbury Invited Commentary Ann. Thorac. Surg., December 1, 2008; 86(6): 1798 - 1798. [Full Text] [PDF] |
||||