ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Ann Thorac Surg 2008;86:828-831. doi:10.1016/j.athoracsur.2008.04.086
© 2008 The Society of Thoracic Surgeons

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Petar M. Vukovic
Miodrag S. Peric
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vukovic, P. M.
Right arrow Articles by KneSevic, A. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vukovic, P. M.
Right arrow Articles by KneSevic, A. M.
Related Collections
Right arrow Coronary disease


Original Articles: Adult Cardiac

Radial Artery Harvesting for Coronary Artery Bypass Grafting: A Stepwise-Made Decision

Petar M. Vukovic, MD*, Sandra S. Radak, MD, Miodrag S. Peric, MD, PhD, Dusko G. NeSic, MD, PhD, Aleksandar M. KneSevic, MD

Department of Cardiac Surgery, Dedinje Cardiovascular Institute, Belgrade, Serbia

Accepted for publication April 24, 2008.

* Address correspondence to Dr Vukovic, Milana Tepica 1, Belgrade, 11040, Serbia (Email: petarvuk{at}eunet.yu).

Background: The purpose of this study was to propose a safe, stepwise, testing system to select radial arteries that are suitable for conduits on the basis of their morphologies and characteristics of the collateral circulation.

Methods: Before operation, 113 patients underwent the modified Allen test, Doppler ultrasonography, and pulse oximetry testing. Morphologic criteria used for radial artery exclusion were small size of radial or ulnar artery (< 2 mm in inner diameter), diffuse calcifications, and congenital anomalies of forearm arteries. Collateral circulation was interpreted as insufficient if the reverse flow in the anatomic snuffbox was absent or if the increase of the ulnar peak systolic flow velocity was less than 20%.

Results: A positive modified Allen test was found in 10.6% of patients. As assessed by Doppler ultrasonography, 27 patients (23.9%) were not candidates for radial artery harvesting according to morphologic and functional abnormalities of forearm and hand circulation. Pulse oximetry test results were abnormal in 6.2%. After a follow-up period of 8.9 ± 1.8 months, 23 patients (29.1% of operated patients) were controlled for Doppler ultrasonographic changes in the ulnar artery. The mean peak systolic flow velocity was significantly higher than the preoperative value measured at rest (p < 0 .001).

Conclusions: After preoperative tests, including the modified Allen test, Doppler ultrasonography, and pulse oximetry, 30.1% of patients were not considered candidates for radial artery harvesting. This method provides preoperative radial artery selection according to its morphologies, compensatory capacity of collateral circulation, and anatomic properties of ulnar artery.