ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Ann Thorac Surg 2008;85:1639-1644. doi:10.1016/j.athoracsur.2008.01.052
© 2008 The Society of Thoracic Surgeons

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Jack G. Copeland
Richard G. Smith
Raj K. Bose
Pei H. Tsau
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Copeland, J. G.
Right arrow Articles by Slepian, M. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Copeland, J. G.
Right arrow Articles by Slepian, M. J.
Related Collections
Right arrow Mechanical Circulatory Assistance
Right arrowRelated Article


Original Articles: Adult Cardiac

Risk Factor Analysis for Bridge to Transplantation With the CardioWest Total Artificial Heart

Jack G. Copeland, MDa,*, Richard G. Smith, MSEEb, Raj K. Bose, MDa, Pei H. Tsau, MDa, Paul E. Nolan, PharmDc, Marvin J. Slepian, MDa

a Sarver Heart Center, University of Arizona, Tucson, Arizona
b Marshall Foundation Artificial Heart Program, University of Arizona, Tucson, Arizona
c Department of Pharmacy, University of Arizona, Tucson, Arizona

Accepted for publication January 17, 2008.

* Address correspondence to Dr Copeland, University of Arizona Sarver Heart Center, 1501 N Campbell Ave, Tucson, AZ 85724-6071 (Email: jackcope3{at}aol.com).

Background: Safety and efficacy studies of various mechanical circulatory support devices are important, but may not be strictly comparable. Lacking prospective randomized studies for different devices, we believe that comparison of risk factor analyses may give the surgeon a tool more powerful than current studies for matching a patient with an appropriate device. In this paper, we report risk factor profiles for bridge to transplantation with the CardioWest total artificial heart and summarize reports for other devices.

Methods: A multiinstitutional risk factor analysis of the CardioWest total artificial heart, as a bridge to transplantation in 81 patients, was conducted. Univariate analyses were performed on 43 preimplantation prognostic factors. From this group, eight factors were chosen for multivariate analysis. Our results were compared with all recent risk factor analyses for other devices.

Results: Independent predictors for death at three intervals by multivariate analysis were as follows: "implant to transplant": history of smoking (odds ratio, 34); "implant to 30 days after transplant": history of smoking (odds ratio, 10.00), prothrombin time greater than 16 seconds (odds ratio, 4.76); and "implant to 1 year after transplant": prothrombin time greater than 16 seconds (odds ratio, 3.85). The major difference between this experience and multiple reported experiences with left ventricular assist devices is that for left ventricular assist devices, but not for the temporary CardioWest total artificial heart, right heart failure, high central venous pressure, and being on a ventilator (with or without sepsis) were independent predictors of mortality.

Conclusions: Risk factors for bridge to transplantation with the CardioWest total artificial heart are different from those reported for left ventricular assist devices. Recognition of these risk factor differences may facilitate appropriate device selection.


Related Article

Invited Commentary
Reiner Koerfer
Ann. Thorac. Surg. 2008 85: 1645. [Extract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
D. E. Jaroszewski, C. C. Pierce, L. L. Staley, R. Wong, R. R. Scott, E. E. Steidley, R. S. Gopalan, P. DeValeria, L. Lanza, D. Mulligan, et al.
Simultaneous Heart and Kidney Transplantation After Bridging With The CardioWest Total Artificial Heart.
Ann. Thorac. Surg., October 1, 2009; 88(4): 1324 - 1326.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
F. Nicolini and T. Gherli
Alternatives to transplantation in the surgical therapy for heart failure
Eur. J. Cardiothorac. Surg., February 1, 2009; 35(2): 214 - 228.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. Koerfer
Invited Commentary
Ann. Thorac. Surg., May 1, 2008; 85(5): 1645 - 1645.