Wessex Cardiac Unit, Southampton University Hospital, Southampton, United Kingdom
Accepted for publication August 13, 2007.
* Address correspondence to Dr Dawkins, Wessex Cardiac Unit, Southampton University Hospital, Southampton SO16 6YD, United Kingdom (Email: keith{at}dawkins.org).
Background: Conducting system defects are common in patients with aortic valve disease. Aortic valve replacement may result in further conduction abnormalities and necessitate permanent pacemaker implantation (PPM). We sought to identify the contemporary incidence and predictors for early postoperative PPM in patients undergoing isolated aortic valve replacement.
Methods: Data were analyzed from 354 consecutive patients undergoing isolated aortic valve replacement at a referral cardiac unit during a 30-month period; data were unavailable on 4 patients and a further 8 had undergone preoperative PPM. Results for the remaining 342 patients (97%; mean age, 67 ± 14 years), of whom 212 were males, are presented. The major indications for aortic valve replacement were valvular stenosis (n = 224), regurgitation (n = 70), or infective endocarditis (n = 25). Preoperative conducting system disease was present in 26% of patients.
Results: In-hospital mortality was 1.8% (6 of 342 patients). Postoperatively 29 patients (8.5%) required early PPM, of which 26 were during the index admission. Patients with preoperative conducting system disease (16% versus 6%; p = 0.004) and valvular regurgitation (16% versus 7%; p = 0.01) were more likely to require PPM as opposed to those without. Preoperative conducting system disease was the only independent predictor of PPM (p < 0.01); the relative risk of PPM requirement in this group was 2.88 (95% confidence interval, 1.31 to 6.33).
Conclusions: Permanent pacemaker implantation requirement after aortic valve replacement is a common occurrence, and should be discussed as part of the preoperative consent process. Preexisting conducting disease and preoperative aortic regurgitation were predictors of PPM requirement.
This article has been cited by other articles:
![]() |
R. Bagur, J. M. Manazzoni, E. Dumont, D. Doyle, J. Perron, F. Dagenais, P. Mathieu, R. Baillot, E. Charbonneau, J. Metras, et al. Permanent pacemaker implantation following isolated aortic valve replacement in a large cohort of elderly patients with severe aortic stenosis Heart, October 15, 2011; 97(20): 1687 - 1694. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. D'Ancona, M. Pasic, A. Unbehaun, and R. Hetzer Permanent pacemaker implantation after transapical transcatheter aortic valve implantation Interact CardioVasc Thorac Surg, October 1, 2011; 13(4): 373 - 376. [Abstract] [Full Text] [PDF] |
||||
![]() |
R.-J. Nuis, N. M. Van Mieghem, C. J. Schultz, A. Tzikas, R. M. Van der Boon, A.-M. Maugenest, J. Cheng, N. Piazza, R. T. van Domburg, P. W. Serruys, et al. Timing and potential mechanisms of new conduction abnormalities during the implantation of the Medtronic CoreValve System in patients with aortic stenosis Eur. Heart J., August 2, 2011; 32(16): 2067 - 2074. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Al-Lamee, C. Godino, and A. Colombo Transcatheter Aortic Valve Implantation: Current Principles of Patient and Technique Selection and Future Perspectives Circ Cardiovasc Interv, August 1, 2011; 4(4): 387 - 395. [Full Text] [PDF] |
||||
![]() |
M. Z. Khawaja, R. Rajani, A. Cook, A. Khavandi, A. Moynagh, S. Chowdhary, M. S. Spence, S. Brown, S. Q. Khan, N. Walker, et al. Permanent Pacemaker Insertion After CoreValve Transcatheter Aortic Valve Implantation: Incidence and Contributing Factors (the UK CoreValve Collaborative) Circulation, March 8, 2011; 123(9): 951 - 960. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. G. Matthews, I. A. Fazal, M. G. D. Bates, and A. J. Turley In patients undergoing aortic valve replacement, what factors predict the requirement for permanent pacemaker implantation? Interact CardioVasc Thorac Surg, March 1, 2011; 12(3): 475 - 479. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. G. D. Bates, I. G. Matthews, I. A. Fazal, and A. J. Turley Postoperative permanent pacemaker implantation in patients undergoing trans-catheter aortic valve implantation: what is the incidence and are there any predicting factors? Interact CardioVasc Thorac Surg, February 1, 2011; 12(2): 243 - 253. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. B. Leon, N. Piazza, E. Nikolsky, E. H. Blackstone, D. E. Cutlip, A. P. Kappetein, M. W. Krucoff, M. Mack, R. Mehran, C. Miller, et al. Standardized Endpoint Definitions for Transcatheter Aortic Valve Implantation Clinical Trials: A Consensus Report From the Valve Academic Research Consortium J. Am. Coll. Cardiol., January 18, 2011; 57(3): 253 - 269. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. B. Leon, N. Piazza, E. Nikolsky, E. H. Blackstone, D. E. Cutlip, A. P. Kappetein, M. W. Krucoff, M. Mack, R. Mehran, C. Miller, et al. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium Eur. Heart J., January 6, 2011; (2011) ehq406v2. [Abstract] [Full Text] [PDF] |
||||
![]() |
R.-J. Nuis and P. de Jaegere Electrocardiographic and further predictors for permanent pacemaker requirements after transcatheter aortic valve implantation Europace, August 1, 2010; 12(8): 1061 - 1062. [Full Text] [PDF] |
||||
![]() |
J.-B. Masson, J. Kovac, G. Schuler, J. Ye, A. Cheung, S. Kapadia, M. E. Tuzcu, S. Kodali, M. B. Leon, and J. G. Webb Transcatheter Aortic Valve Implantation: Review of the Nature, Management, and Avoidance of Procedural Complications J. Am. Coll. Cardiol. Intv., September 1, 2009; 2(9): 811 - 820. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. Jokinen, A. K. Turpeinen, O. Pitkanen, M. J. Hippelainen, and J. E.K. Hartikainen Pacemaker Therapy After Tricuspid Valve Operations: Implications on Mortality, Morbidity, and Quality of Life Ann. Thorac. Surg., June 1, 2009; 87(6): 1806 - 1814. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Grube, L. Buellesfeld, R. Mueller, B. Sauren, B. Zickmann, D. Nair, H. Beucher, T. Felderhoff, S. Iversen, and U. Gerckens Progress and Current Status of Percutaneous Aortic Valve Replacement: Results of Three Device Generations of the CoreValve Revalving System Circ Cardiovasc Interv, December 1, 2008; 1(3): 167 - 175. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Talwar, S. K. Choudhary, and A. S. Kumar Permanent Pacemaker Implantation After Isolated Aortic Valve Replacement Ann. Thorac. Surg., October 1, 2008; 86(4): 1403 - 1403. [Full Text] [PDF] |
||||
![]() |
A. M. Greve and K. Wachtell Review: Does lowering cholesterol have an impact on the progression of aortic stenosis? Therapeutic Advances in Cardiovascular Disease, August 1, 2008; 2(4): 277 - 286. [Abstract] [PDF] |
||||
![]() |
N. Piazza, Y. Onuma, E. Jesserun, P. P. Kint, A.-M. Maugenest, R. H. Anderson, P. P. T. de Jaegere, and P. W. Serruys Early and Persistent Intraventricular Conduction Abnormalities and Requirements for Pacemaking After Percutaneous Replacement of the Aortic Valve J. Am. Coll. Cardiol. Intv., June 1, 2008; 1(3): 310 - 316. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |