ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Ann Thorac Surg 2008;85:108-112. doi:10.1016/j.athoracsur.2007.08.024
© 2008 The Society of Thoracic Surgeons

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Augustine T.M. Tang
James L. Monro
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dawkins, S.
Right arrow Articles by Dawkins, K. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dawkins, S.
Right arrow Articles by Dawkins, K. D.
Related Collections
Right arrow Electrophysiology - arrhythmias


Original Articles: Cardiovascular

Permanent Pacemaker Implantation After Isolated Aortic Valve Replacement: Incidence, Indications, and Predictors

Sam Dawkins, MB BS, Alex R. Hobson, MB BS, Paul R. Kalra, MD, Augustine T.M. Tang, DM, FRCS Ed (C-Th), James L. Monro, FRCS, Keith D. Dawkins, MD, FRCP*

Wessex Cardiac Unit, Southampton University Hospital, Southampton, United Kingdom

Accepted for publication August 13, 2007.

* Address correspondence to Dr Dawkins, Wessex Cardiac Unit, Southampton University Hospital, Southampton SO16 6YD, United Kingdom (Email: keith{at}dawkins.org).

Background: Conducting system defects are common in patients with aortic valve disease. Aortic valve replacement may result in further conduction abnormalities and necessitate permanent pacemaker implantation (PPM). We sought to identify the contemporary incidence and predictors for early postoperative PPM in patients undergoing isolated aortic valve replacement.

Methods: Data were analyzed from 354 consecutive patients undergoing isolated aortic valve replacement at a referral cardiac unit during a 30-month period; data were unavailable on 4 patients and a further 8 had undergone preoperative PPM. Results for the remaining 342 patients (97%; mean age, 67 ± 14 years), of whom 212 were males, are presented. The major indications for aortic valve replacement were valvular stenosis (n = 224), regurgitation (n = 70), or infective endocarditis (n = 25). Preoperative conducting system disease was present in 26% of patients.

Results: In-hospital mortality was 1.8% (6 of 342 patients). Postoperatively 29 patients (8.5%) required early PPM, of which 26 were during the index admission. Patients with preoperative conducting system disease (16% versus 6%; p = 0.004) and valvular regurgitation (16% versus 7%; p = 0.01) were more likely to require PPM as opposed to those without. Preoperative conducting system disease was the only independent predictor of PPM (p < 0.01); the relative risk of PPM requirement in this group was 2.88 (95% confidence interval, 1.31 to 6.33).

Conclusions: Permanent pacemaker implantation requirement after aortic valve replacement is a common occurrence, and should be discussed as part of the preoperative consent process. Preexisting conducting disease and preoperative aortic regurgitation were predictors of PPM requirement.




This article has been cited by other articles:


Home page
J Am Coll Cardiol IntvHome page
J.-B. Masson, J. Kovac, G. Schuler, J. Ye, A. Cheung, S. Kapadia, M. E. Tuzcu, S. Kodali, M. B. Leon, and J. G. Webb
Transcatheter Aortic Valve Implantation: Review of the Nature, Management, and Avoidance of Procedural Complications
J. Am. Coll. Cardiol. Intv., September 1, 2009; 2(9): 811 - 820.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. J. Jokinen, A. K. Turpeinen, O. Pitkanen, M. J. Hippelainen, and J. E.K. Hartikainen
Pacemaker Therapy After Tricuspid Valve Operations: Implications on Mortality, Morbidity, and Quality of Life.
Ann. Thorac. Surg., June 1, 2009; 87(6): 1806 - 1814.
[Abstract] [Full Text] [PDF]


Home page
Circ Cardiovasc IntervHome page
E. Grube, L. Buellesfeld, R. Mueller, B. Sauren, B. Zickmann, D. Nair, H. Beucher, T. Felderhoff, S. Iversen, and U. Gerckens
Progress and Current Status of Percutaneous Aortic Valve Replacement: Results of Three Device Generations of the CoreValve Revalving System
Circ Cardiovasc Interv, December 1, 2008; 1(3): 167 - 175.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Talwar, S. K. Choudhary, and A. S. Kumar
Permanent Pacemaker Implantation After Isolated Aortic Valve Replacement
Ann. Thorac. Surg., October 1, 2008; 86(4): 1403 - 1403.
[Full Text] [PDF]


Home page
Ther Adv Cardiovasc DisHome page
A. M. Greve and K. Wachtell
Review: Does lowering cholesterol have an impact on the progression of aortic stenosis?
Therapeutic Advances in Cardiovascular Disease, August 1, 2008; 2(4): 277 - 286.
[Abstract] [PDF]


Home page
J Am Coll Cardiol IntvHome page
N. Piazza, Y. Onuma, E. Jesserun, P. P. Kint, A.-M. Maugenest, R. H. Anderson, P. P. T. de Jaegere, and P. W. Serruys
Early and Persistent Intraventricular Conduction Abnormalities and Requirements for Pacemaking After Percutaneous Replacement of the Aortic Valve
J. Am. Coll. Cardiol. Intv., June 1, 2008; 1(3): 310 - 316.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2008 by The Society of Thoracic Surgeons.