a Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia
b Harrison Department of Surgical Research, University of Pennsylvania School of Medicine, Philadelphia, Pennsylvania
Accepted for publication May 30, 2007.
* Address correspondence to Dr Yoganathan, Wallace H. Coulter School of Biomedical Engineering, Georgia Institute of Technology and Emory University, Room 2119 U.A. Whitaker Building, 313 Ferst Dr, Atlanta, GA 30332-0535 (Email: ajit.yoganathan{at}bme.gatech.edu).
Background: The edge-to-edge repair to correct mitral regurgitation (MR) has shown substandard results in cases of ischemic MR or dilated cardiomyopathy.
Methods: Ten porcine mitral valves were investigated in a left heart simulator (120 mm Hg, 5 L/min). Pathologic conditions of a dilated ventricle were simulated by using an annular model capable of three levels of dilation (normal, 56%, and 120%) and by displacing papillary muscles (PMs) 10 mm in the apical, lateral, and posterior directions. The edge-to-edge repair was performed; a central stitch was investigated for symmetric and asymmetric PM displacements, and a paracommissural stitch was investigated for asymmetric PM displacements. Left ventricular pressure and mitral flow rate were monitored, and regurgitation fraction was calculated from the mitral flow curve.
Results: Under symmetric PM displacement, the repair reduced MR by 5.1% at dilation level one and by 9.1% at dilation level two. The repair decreased MR by 10.9% (dilation level two) after asymmetric displacement of the anterior-lateral PM, and by 5.4% (dilation level one) and 7.9% (dilation level two) after asymmetric displacement of the posterior-medial PM. The edge-to-edge repair reduced (p < 0.05) MR owing to annular dilation; however, it was unable to completely eliminate the MR. The repair did not significantly reduce MR caused by PM displacement, regardless of the displacement geometry. Stitch location did not affect repair efficacy.
Conclusions: The edge-to-edge repair is not an effective procedure in correcting MR associated with PM displacement, although it is able to partially reduce MR caused by annular dilation.
This article has been cited by other articles:
![]() |
J.-H. Kim, O. Kocaturk, C. Ozturk, A. Z. Faranesh, M. Sonmez, S. Sampath, C. E. Saikus, A. H. Kim, V. K. Raman, J. A. Derbyshire, et al. Mitral cerclage annuloplasty, a novel transcatheter treatment for secondary mitral valve regurgitation: initial results in swine. J. Am. Coll. Cardiol., August 11, 2009; 54(7): 638 - 651. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. A. Timek, D. T. Lai, D. Liang, D. C. Miller, S. L. Nielsen, G. T. Daughters, and N. B. Ingels Response to Letter Regarding Article, "Effect of Chronotropy and Inotropy on Stitch Tension in the Edge-to-Edge Mitral Repair" Circulation, July 22, 2008; 118(4): e79 - e79. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |