ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Ann Thorac Surg 2007;84:1571-1577. doi:10.1016/j.athoracsur.2007.06.026
© 2007 The Society of Thoracic Surgeons

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ando, M.
Right arrow Articles by Takahashi, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ando, M.
Right arrow Articles by Takahashi, Y.
Related Collections
Right arrow Valve disease


Original Articles: Cardiovascular

Edge-to-Edge Repair of Common Atrioventricular or Tricuspid Valve in Patients With Functionally Single Ventricle

Makoto Ando, MD*, Yukihiro Takahashi, MD

Department of Pediatric Cardiac Surgery, Sakakibara Heart Institute, Tokyo, Japan

Accepted for publication June 1, 2007.

* Address correspondence to Dr Ando, Department of Pediatric Cardiac Surgery, Sakakibara Heart Institute, 3-16-1 Asahi-cho, Fuchu-si, Tokyo, 183-0003, Japan (Email: maando{at}shi.heart.or.jp).

Presented at the Forty-third Annual Meeting of The Society of Thoracic Surgeons, San Diego, CA, Jan 29–31, 2007.

Background: There is a limitation to the ability of the tricuspid or common atrioventricular valve to function in the systemic position, and insufficiency of these valves often carries an important risk during the staged surgical reconstruction in single ventricle. The purpose of this study was to assess the efficacy of edge-to-edge repair, involving suturing of the free-floating segments of the opposing leaflets, applied in this context.

Methods: Between 1989 and 2006, 49 patients with tricuspid or common atrioventricular valve regurgitation (moderate or greater) associated with single ventricle underwent valve repair 53 times. Edge-to-edge repair was performed in 5 of 23 with tricuspid valve and 17 of 30 with common atrioventricular valve.

Results: In the edge-to-edge group, more patients had severe regurgitation (59.1%) compared with the non–edge-to-edge group (32.3%) before operation (p = 0.0906). The postoperative degree of regurgitation was mild or less in 95.5% of the edge-to-edge group compared with 48.4% of the non–edge-to-edge group (p = 0.0003). Tricuspid or atrioventricular valve stenosis was not observed in any of the patients after repair. The degree of regurgitation on follow-up echocardiogram was mild or less in 77.3% of the edge-to-edge group at 2.6 ± 4.0 years after repair, compared with 38.7% of the non–edge-to-edge group at 1.9 ± 3.2 years (p = 0.109).

Conclusions: Edge-to-edge repair was an effective adjunctive in repairing tricuspid or common atrioventricular valve associated with functionally single ventricle. An excellent reduction of regurgitation was observed in most of the patients, and may lead to preservation of ventricular function during interim stage and successful completion of the Fontan operation.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2007 by The Society of Thoracic Surgeons.