ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Ann Thorac Surg 2007;84:1504-1507. doi:10.1016/j.athoracsur.2007.06.006
© 2007 The Society of Thoracic Surgeons

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Tadashi Tashiro
Hideki Teshima
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Iwahashi, H.
Right arrow Articles by Kuwahara, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Iwahashi, H.
Right arrow Articles by Kuwahara, G.
Related Collections
Right arrow Coronary disease


Original Articles: Cardiovascular

New Method of Thermal Coronary Angiography for Intraoperative Patency Control in Off-Pump and On-Pump Coronary Artery Bypass Grafting

Hidehiko Iwahashi, MD, PhD*, Tadashi Tashiro, MD, PhD, Noritsugu Morishige, MD, PhD, Yoshio Hayashida, MD, Kazuma Takeuchi, MD, PhD, Nobuhisa Ito, MD, Hideki Teshima, MD, PhD, Go Kuwahara, MD

Department of Cardiovascular Surgery, Fukuoka University School of Medicine, Fukuoka, Japan

Accepted for publication June 1, 2007.

* Address correspondence to Dr Iwahashi, Department of Cardiovascular Surgery, Fukuoka University School of Medicine, 7-45-1 Nanakuma, Jonan-ku, Fukuoka, 814-0180, Japan. (Email: iwahashi{at}fukuoka-u.ac.jp).

Background: We evaluated the effectiveness of a new thermal coronary angiogram system using intraoperative imaging with an infrared camera for coronary artery bypass grafting.

Methods: The thermal coronary angiograms of 51 patients who underwent a total of 107 coronary artery bypass grafts were evaluated. Thermal coronary angiograms were obtained after completing distal anastomoses by the injection of cold saline solution into the vein grafts or free arterial grafts or by reperfusion with warmer blood in the internal thoracic artery grafts. Temperature differences of greater than 0.1°C between the injectant and the epimyocardium resulted in high-contrast images.

Results: Thermal coronary angiograms were obtained from 107 coronary artery bypass grafts; 103 grafts were patent (96.3%), and 2 internal thoracic artery grafts were occluded. After reanastomoses, thermal coronary angiograms were again obtained, and all grafts appeared to be patent. Four grafts did not clearly show hemokinesis because of an intramyocardial segment or circumferential fat surrounding the artery.

Conclusions: Thermal coronary angiograms cannot show hemokinesis clearly in cases with an intramyocardial arterial segment or in patients in whom the grafts are surrounded by fat. Therefore, thermal coronary angiograms are considered to play a valuable role in confirming the success or failure of myocardium revascularization because this diagnostic modality does not interfere with the surgical procedures, is noninvasive, and can be both quickly and easily performed.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
F. Robicsek
Thermal coronary angiography.
Ann. Thorac. Surg., June 1, 2008; 85(6): 2161 - 2162.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2007 by The Society of Thoracic Surgeons.