ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Losanoff, J. E.
Right arrow Articles by Hsieh, F.-h.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Losanoff, J. E.
Right arrow Articles by Hsieh, F.-h.
Related Collections
Right arrow Chest wall

Ann Thorac Surg 2007;84:1288-1293
© 2007 The Society of Thoracic Surgeons


Original Articles: Cardiovascular

Single Wire Versus Double Wire Loops for Median Sternotomy Closure: Experimental Biomechanical Study Using a Human Cadaveric Model

Julian E. Losanoff, MDa,b,*, Marc D. Basson, MD, PhDa,b, Scott A. Gruber, MD, PhDb, Harold Huff, MSc, Fu-hung Hsieh, PhDc

a Department of Surgery, John D. Dingell VA Medical Center, Detroit, Michigan
b Department of Surgery, Wayne State University, Detroit, Michigan
c Department of Biological Engineering, University of Missouri, Columbia, Missouri

Accepted for publication May 9, 2007.

* Address correspondence to Dr Losanoff, Department of Surgery (11S), John D. Dingell VA Medical Center, 4646 John R, Detroit, MI 48201 (Email: jelosanoff{at}yahoo.comtel).

Background: Healing of median sternotomy requires reliable sternal fixation. Although both single and double wire kits are commercially available, no experimental study has compared the two closures in a human cadaveric model. We used a recently described human experimental cadaveric model to compare the stability of the closures.

Methods: Sixteen fresh adult human cadaveric sternal plates with adjacent ribs were fixed with custom designed spiked stainless steel clamps and attached to a biomechanical testing device. Single No. 5 peristernal and double peristernal closures were tested. The stability of the unions was tested using perpendicular, repetitive force loads increasing from 0 to 800 Newtons at a rate of 0.5 mm/second.

Results: The two study groups did not differ in age or sex. No clamp failures or damage to the specimens occurred. The double peristernal closure exhibited a significantly lower permanent displacement than the single wire group, suggesting a superior strength and stability of that closure.

Conclusions: To the extent to which this human cadaveric model resembles in vivo median sternotomy, these data suggest that the biomechanical stability of the peristernal double wire closure may exceed that of single wires.







HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2007 by The Society of Thoracic Surgeons.