|
|
||||||||
Ann Thorac Surg 2007;84:1092-1097
© 2007 The Society of Thoracic Surgeons
a Division of Cardiothoracic Surgery, Department of Surgery, University of Alabama at Birmingham School of Public Health, Birmingham, Alabama
b Department of Epidemiology, University of Alabama at Birmingham School of Public Health, Birmingham, Alabama
Accepted for publication May 14, 2007.
* Address correspondence to Dr Cerfolio, Division of Cardiothoracic Surgery, University of Alabama at Birmingham, 703 19th St S, ZRB 739, Birmingham, AL 35294 (Email: robert.cerfolio{at}ccc.uab.edu).
Presented at the Poster Session of the Forty-third Annual Meeting of The Society of Thoracic Surgeons, San Diego, CA, Jan 29–31, 2007.
Background: The ideal time to repeat a 2-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET)/computed tomography (CT) scan to accurately restage a patient after neoadjuvant chemoradiotherapy for non-small cell lung cancer (NSCLC) is unknown.
Methods: This retrospective cohort study used a prospective database of patients who underwent neoadjuvant chemoradiotherapy, an initial and repeat FDG-PET/CT scan, and pathologic staging. The accuracy of the clinical stage suggested by repeat FDG-PET/CT was compared with the actual pathologic stage. Receiver operating characteristic (ROC) curves were used to determine when it was most accurate to repeat the FDG-PET/CT after the completion of the last dose of chest radiation.
Results: The study comprised 109 patients, 93 of whom patients received 60 Gy (or higher) of radiotherapy. The median time to restaging was 24 days (range, 2 to 88 days). ROC analysis showed the optimal time to restage patients was 26 days for overall staging (area under the curve [AUC], 0.88) and 29 days for N2 restaging (AUC, 0.82). The accuracy for overall stage was 3 (38%) of 8 for patients for less than 10 days, 28 (72%) of 39 for patients between 11 and 20 days, 42 (88%) of 49 between 21 and 30 days, and 8 (62%) of 13 for 31 days or more. The accuracy for these time intervals for the restaging of the N2 lymph node was 50% (1/2) 40% (2/5), 88% (7/8), and 100% (3/3), respectively.
Conclusions: The optimal time to perform a repeat FDG-PET/CT scan after the completion of neoadjuvant chemotherapy and high-dose radiotherapy to maximize its accuracy for restaging patients with NSCLC is about 1 month after the last dose of radiation.
This article has been cited by other articles:
![]() |
R. J. Cerfolio, A. S. Bryant, V. L. Jones, and R. M. Cerfolio Pulmonary resection after concurrent chemotherapy and high dose (60 Gy) radiation for non-small cell lung cancer is safe and may provide increased survival Eur. J. Cardiothorac. Surg., April 1, 2009; 35(4): 718 - 723. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Cerfolio, A. S. Bryant, A. A. Talati, R. M. Cerfolio, and T. S. Winokur Change in maximum standardized uptake value on repeat positron emission tomography after chemoradiotherapy in patients with esophageal cancer identifies complete responders. J. Thorac. Cardiovasc. Surg., March 1, 2009; 137(3): 605 - 609. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. A. Weber The Use of Positron Emission Tomography versus Computerized Tomography Scans in the Assessment of Response to Therapy ASCO Educational Book, January 1, 2009; 2009(1): 474 - 478. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |