Ann Thorac Surg 2007;84:264-266
© 2007 The Society of Thoracic Surgeons
a Cardiac Surgery Unit, Magna Graecia University, Catanzaro, Italy
b Cardiology Unit, Magna Graecia University, Catanzaro, Italy
Accepted for publication December 21, 2006.
* Address correspondence to Dr Onorati, Viale dei Pini 28, Napoli, 80131, Italy (Email: frankono{at}libero.it).
Preoperative intraaortic balloon pumping improves the results of complex coronary surgery; however, insertion may be harmful or contraindicated in severe and diffuse atherosclerosis of the descending aorta and peripheral arteries. We report our experience with 10 consecutive patients with severe peripheral atherosclerosis or distal abdominal aortic aneurysms, in whom a 7.5F intraaortic balloon catheter was inserted through the brachial artery. Intraaortic balloon pumping was maintained until hemodynamic stability was established; no complications or ischemia of the hand related to the intraaortic balloon pump occurred. Transbrachial intraaortic balloon pumping with a 7.5F catheter is as safe and effective as the transfemoral method in patients with unavailable femoral arteries.
This article has been cited by other articles:
![]() |
S. Bundhoo, P. A. O'Keefe, H. Luckraz, and N. Ossei-Gerning Extended duration of brachially inserted intra-aortic balloon pump for myocardial protection in two patients undergoing urgent coronary artery bypass grafting Interactive CardioVascular and Thoracic Surgery, February 1, 2008; 7(1): 42 - 44. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |