ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Oved Cohen
Jonah Odim
Kathy Palatnik
Hillel Laks
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cohen, O.
Right arrow Articles by Laks, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cohen, O.
Right arrow Articles by Laks, H.

Ann Thorac Surg 2007;83:S780-S784
© 2007 The Society of Thoracic Surgeons


Supplement

Long-Term Experience of Girdling the Ascending Aorta With Dacron Mesh as Definitive Treatment for Aneurysmal Dilation

Oved Cohen, MD*, Jonah Odim, MD, PhD, David De La Zerda, MD, Chidi Ukatu, MD, Raj Vyas, BS, Neil Vyas, BA, Kathy Palatnik, BS, Hillel Laks, MD

Division of Cardiac Surgery, David Geffen School of Medicine at University of California, Los Angeles, Los Angeles, California

* Address correspondence to Dr Cohen, Division of Cardiac Surgery, David Geffen School of Medicine at UCLA, 10833 Le Conte Ave, Rm 62-266B, CHS, Los Angeles, CA 90095-1741. (Email: oved.cohen{at}gmail.com).

Presented at Aortic Surgery Symposium X, New York, NY, April 27–28, 2006.

BACKGROUND: The management of the mildly to moderately dilated ascending aorta (3.5 to 4.9 cm) in cardiac surgery remains controversial. Therapeutic options have included radical aortic resection with synthetic graft substitution, external aortic reinforcement or wrap, with or without partial aortic wall excision, and a watch-and-wait approach. We reviewed our institutional experience with Dacron (DuPont, Wilmington, DE) mesh wrap support of dilated ascending aortas.

METHODS: During the last 20 years, 102 patients with aneurysmal dilatation of the ascending aorta underwent wrapping of the ascending aorta with a fine Dacron mesh from the ventricular-aortic junction to the origin of the innominate artery. For the last 10 years, the wrap was anchored to the aortic annulus with pledgeted sutures. Aortic diameters up to 6 cm, without focal areas of thinning, were wrapped. Aortic diameters exceeding 6 cm, or with focal thinning, underwent tailored aortic wall resection and wrapping. Primary end points of the study included mortality, aortic diameter growth, dissection or rupture, or both.

RESULTS: The mean age of the group was 54.7 ± 19 years (range, 12 to 90 years). A single patient underwent aortic wrapping without cardiopulmonary bypass. Sixty-six patients (65%) required additional aortic valve surgery. Five patients (5%) had reinforcement of dilated sinuses with glutaraldehyde-treated pericardial patches combined with wrapping. Twenty-seven patients (26%) had combined coronary and valve surgery, and 2 patients had coronary revascularization alone. There was neither early nor hospital mortality. Among the 81 patients (79%) we were able to contact, 7 (7%) late deaths had occurred at 0.5, 1, 3, and 9 years after operation that were unrelated to aortic pathology. Various levels of follow-up were obtained in the 88 patients (86.2%). In 78 patients, echocardiograms, computed tomography angiograms, or magnetic resonance angiograms were obtained. In 2 of these patients, aneurysmal dilatation of the sinuses developed below the wrap and reoperation was required. No patient in whom the mesh wrap was anchored to the aortic annulus required reoperation. All 81 patients that were contacted by us and monitored by referring physicians were asymptomatic and free of problems related to the aorta. The mean (± SD) preoperative diameter of the ascending aorta was 49.2 ± 7.8 mm (range, 35 to 87 mm), the postwrap intraoperative diameter was 32.9 ± 3.4 mm (range, 20 to 40 mm), and the follow-up postoperative aortic diameter was 35.6 ± 12.7 mm (range, 27 to 52 mm). The mean average change in the aortic diameter during the follow-up period was 2.6 ± 14.8 mm (range, –7 to 22 mm), a mean of 8%. The mean follow-up period was 5.7 years (median, 4.77 years; range, 9 days to 21 years). There were no infections or other early complications related to the wrap.

CONCLUSIONS: Dacron mesh support of the moderately dilated aneurysmal ascending aorta, alone or in conjunction with coronary revascularization, aortic root surgery, or valvular operations, or both, is safe and durable. Dacron mesh is transparent and stretchable, permitting tight girdling of the aorta. These properties prevent hematoma formation, facilitate proximal vein graft anastomoses, and provide visualization and access to aortic suture lines. Finally, this technique retards further aortic dilation, altering the natural history of aortic aneurysms.