Ann Thorac Surg 2007;83:450-455
© 2007 The Society of Thoracic Surgeons
a Department of Cardiothoracic Surgery, University of Vienna Medical School, Vienna, Austria
b Department of Interventional Radiology, University of Vienna Medical School, Vienna, Austria
Accepted for publication August 15, 2006.
* Address correspondence to Dr Czerny, Waehringer Guertel 18-20, A-1090 Vienna, Austria (Email: bypass{at}eunet.at).
Presented at the Poster Session of the Forty-second Annual Meeting of The Society of Thoracic Surgeons, Chicago, IL, Jan 30Feb 1, 2006.
BACKGROUND: The purpose of this study was to determine durability and need for reinterventions after endovascular stent graft placement in atherosclerotic aneurysms involving the descending aorta.
METHODS: We performed a prospective follow-up analysis of a consecutive series of 79 patients undergoing endovascular stent graft placement due to atherosclerotic aneurysms involving the descending aorta between 1996 and 2006. Acute aortic syndromes were excluded from this analysis. Mean follow-up was 42 months (range, 1 to 108 months). Data were collected for in-hospital mortality, occurrence of early and late endoleaks, reintervention due to early and late endoleaks, and survival.
RESULTS: In-hospital mortality was 6.3% (n = 5). Two of these patients underwent emergent treatment. Early type I and III endoleaks were observed in 29% of patients (n = 23). The assisted primary endoleak rate was 11%. Late type I or III endoleaks occurred in 21% (n = 17). At 1, 3, and 5 years, overall actuarial survival was 96%, 86%, and 69%, and event-free survival was 90%, 82%, and 65%, respectively. Cox proportional hazard analysis revealed that a short proximal landing zone and a high number of stent grafts used were independent risk factors for early and late endoleak formation. Late endoleak formation was an independent predictor of survival.
CONCLUSIONS: Endovascular stent graft placement in atherosclerotic aneurysms involving the descending aorta has satisfactory durability. An extensive landing zone is a prerequisite of early and late success. Further clinical investigations are warranted to evaluate long-term durability of this attractive treatment modality.
This article has been cited by other articles:
![]() |
M. Funovics, M. Blum, H. Langenberger, C. Plank, M. Schoder, G. Edelhauser, R. Gottardi, D. Berzacky, M. Dorfmeister, M. Grimm, et al. Endovascular repair of the descending aorta and the aortic arch with the Relay stent graft. Ann. Thorac. Surg., August 1, 2009; 88(2): 637 - 640. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Ohtake, S. Tomita, S. Yamaguchi, S. Yoshida, K. Kimura, J. Sanada, O. Matsui, and G. Watanabe An experimental study of type I endoleak repair with a suturing device. Ann. Thorac. Surg., July 1, 2009; 88(1): 258 - 261. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Schuster, M. Dorfmeister, S. Scheuter-Mlaker, R. Gottardi, M. Hoebartner, S. Roedler, T. Dziodzio, A. Juraszek, C. Loewe, M. Funovics, et al. Endovascular and Conventional Treatment of Thoracic Aortic Aneurysms: A Comparison of Costs. Ann. Thorac. Surg., June 1, 2009; 87(6): 1801 - 1805.e6. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. S. Ramanath, J. K. Oh, T. M. Sundt III, and K. A. Eagle Acute Aortic Syndromes and Thoracic Aortic Aneurysm Mayo Clin. Proc., May 1, 2009; 84(5): 465 - 481. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Y. Sze, M. A.A.J. van den Bosch, M. D. Dake, D. C. Miller, L. V. Hofmann, R. Varghese, S. C. Malaisrie, P. J.A. van der Starre, J. Rosenberg, and R. S. Mitchell Factors Portending Endoleak Formation After Thoracic Aortic Stent-Graft Repair of Complicated Aortic Dissection Circ Cardiovasc Interv, April 1, 2009; 2(2): 105 - 112. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. D. Adams, J. F. Angle, A. H. Matsumoto, B. B. Peeler, B. Arslan, K. J. Cherry, J. A. Kern, and M. D. Dake Endovascular repair of the thoracic aorta in the post-FDA approval era. J. Thorac. Cardiovasc. Surg., January 1, 2009; 137(1): 117 - 123. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Gottardi, M. Funovics, N. Eggers, A. Hirner, M. Dorfmeister, J. Holfeld, D. Zimpfer, M. Schoder, K. Donas, E. Weigang, et al. Supra-aortic Transposition for Combined Vascular and Endovascular Repair of Aortic Arch Pathology Ann. Thorac. Surg., November 1, 2008; 86(5): 1524 - 1529. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. D. Peterson, G. H. Wheatley III, J. Kpodonu, J. P. Williams, V. G. Ramaiah, J. A. Rodriguez-Lopez, and E. B. Diethrich Treatment of type II endoleaks associated with left subclavian artery coverage during thoracic aortic stent grafting. J. Thorac. Cardiovasc. Surg., November 1, 2008; 136(5): 1193 - 1199. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Grimm, C. Loewe, R. Gottardi, M. Funovics, D. Zimpfer, S. Rodler, M. Dorfmeister, M. Schoder, J. Lammer, S. Aharinejad, et al. Novel Insights Into the Mechanisms and Treatment of Intramural Hematoma Affecting the Entire Thoracic Aorta Ann. Thorac. Surg., August 1, 2008; 86(2): 453 - 456. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. P. Siegenthaler, R. Celik, J. Haberstroh, P. Bajona, H. Goebel, K. Brehm, W. Euringer, and F. Beyersdorf Thoracic endovascular stent grafting inhibits aortic growth: an experimental study. Eur. J. Cardiothorac. Surg., July 1, 2008; 34(1): 17 - 24. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Gottardi, D. Zimpfer, M. Funovics, M. Schoder, J. Lammer, E. Wolner, M. Czerny, and M. Grimm Mid-term results after endovascular stent-graft placement due to penetrating atherosclerotic ulcers of the thoracic aorta Eur. J. Cardiothorac. Surg., June 1, 2008; 33(6): 1019 - 1024. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Khoynezhad, C. E. Donayre, J. Smith, G. E. Kopchok, I. Walot, and R. A. White Risk factors for early and late mortality after thoracic endovascular aortic repair. J. Thorac. Cardiovasc. Surg., May 1, 2008; 135(5): 1103 - 1109.e4. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Czerny, D. Zimpfer, S. Rodler, M. Funovics, M. Dorfmeister, M. Schoder, G. Marta, E. Weigang, R. Gottardi, J. Lammer, et al. Endovascular Stent-Graft Placement of Aneurysms Involving the Descending Aorta Originating From Chronic Type B Dissections Ann. Thorac. Surg., May 1, 2007; 83(5): 1635 - 1639. [Abstract] [Full Text] [PDF] |
||||