ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Stephan Jacobs
Michael Mochalski
Thomas Walther
Friedrich W. Mohr
Volkmar Falk
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Holzhey, D. M.
Right arrow Articles by Falk, V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Holzhey, D. M.
Right arrow Articles by Falk, V.
Related Collections
Right arrow Coronary disease

Ann Thorac Surg 2007;83:108-114
© 2007 The Society of Thoracic Surgeons


Original Articles: Cardiovascular

Seven-Year Follow-up After Minimally Invasive Direct Coronary Artery Bypass: Experience With More Than 1300 Patients

David M. Holzhey, MDa,*, Stephan Jacobs, MDa, Michael Mochalski, MDa, Thomas Walther, MD, PhDa, Holger Thiele, MD, PhDb, Friedrich W. Mohr, MD, PhDa, Volkmar Falk, MD, PhDa

a Department of Cardiac Surgery, Heart Center Leipzig, Leipzig, Germany
b Department of Cardiology, Heart Center Leipzig, Leipzig, Germany

Accepted for publication August 14, 2006.

* Address correspondence to Dr Holzhey, Herzzentrum Leipzig, Strümpellstrasse 39, 04289 Leipzig, Germany (Email: dholzhey{at}web.de).

BACKGROUND: Minimally invasive direct coronary artery bypass (MIDCAB) for revascularization of the left anterior descending artery has become a routine operation. Here we present the experience after more than 1300 MIDCAB procedures with up to 7 years of follow-up.

METHODS: All patients undergoing standard MIDCAB between 1996 and 2004 were included. Long-term follow-up information about health status, major cardiac and cerebral adverse events, and freedom of angina was collected annually by a questionnaire or personal contact. Preoperative, intraoperative, and postoperative data could be completed for all 1347 patients. Five-year follow-up was available for 450 patients and 7-year follow-up for 194 patients.

RESULTS: Mean age was 63.2 years (range, 25 to 92 years) and mean ejection fraction was 0.61 ± 0.14. In 23 patients (1.7%), intraoperative conversion to sternotomy or CPB, or both, was necessary. Early postoperative mortality was 0.8% (n = 11), and 0.4% (n = 5) had a perioperative stroke. A routine postoperative angiogram in 709 patients showed 95.6% early graft patency. Short-term target vessel reintervention was needed 55 patients (4.1%): 10 had percutaneous transluminal coronary angioplasty/stent and 45 had reoperation. A repeat angiogram at the 6-month follow-up was available in 350 patients and demonstrated 94.3% graft patency. Kaplan-Meier analysis revealed a 5-year survival of 91.9% (95% confidence interval [CI], 90.1% to 93.8%) and a 7-year survival of 89.4% (95% CI, 86.7% to 92.1%). The freedom of major adverse events and angina was 89.5% (95% CI, 87.4% to 91.5%) after 5 years and 83.3% (95% CI, 79.0% to 87.5%) after 7 years.

CONCLUSIONS: MIDCAB can be safely performed with low postoperative mortality and morbidity. The excellent short-term and long-term survival as well as freedom from major adverse cardiac and cerebral events and angina compare favorably with stenting and conventional surgery.




This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
H. Thiele, P. Neumann-Schniedewind, S. Jacobs, E. Boudriot, T. Walther, F.-W. Mohr, G. Schuler, and V. Falk
Randomized Comparison of Minimally Invasive Direct Coronary Artery Bypass Surgery Versus Sirolimus-Eluting Stenting in Isolated Proximal Left Anterior Descending Coronary Artery Stenosis
J. Am. Coll. Cardiol., June 23, 2009; 53(25): 2324 - 2331.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. M. Holzhey, S. Jacobs, M. Mochalski, D. Merk, T. Walther, F. W. Mohr, and V. Falk
Minimally Invasive Hybrid Coronary Artery Revascularization
Ann. Thorac. Surg., December 1, 2008; 86(6): 1856 - 1860.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
R. C. Becker, T. W. Meade, P. B. Berger, M. Ezekowitz, C. M. O'Connor, D. A. Vorchheimer, G. H. Guyatt, D. B. Mark, and R. A. Harrington
The Primary and Secondary Prevention of Coronary Artery Disease: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines (8th Edition)
Chest, June 1, 2008; 133(6_suppl): 776S - 814S.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
U. Kappert, S.-M. Tugtekin, R. Cichon, M. Braun, and K. Matschke
Robotic totally endoscopic coronary artery bypass: A word of caution implicated by a five-year follow-up.
J. Thorac. Cardiovasc. Surg., April 1, 2008; 135(4): 857 - 862.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. M. Holzhey, S. Jacobs, T. Walther, M. Mochalski, F. W. Mohr, and V. Falk
Cumulative sum failure analysis for eight surgeons performing minimally invasive direct coronary artery bypass
J. Thorac. Cardiovasc. Surg., September 1, 2007; 134(3): 663 - 669.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2007 by The Society of Thoracic Surgeons.