ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Daniel H. Drake
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Drake, D. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Drake, D. H.
Related Collections
Right arrow Chest wall

Ann Thorac Surg 2006;82:1494-1496
© 2006 The Society of Thoracic Surgeons


New Technology

A Wire-Cutting Clamp Designed to Reduce Complications During Sternotomy Closure

Daniel H. Drake, MD*

Department of Surgery, Section of Cardiothoracic Surgery, Munson Medical Center, Traverse City, Michigan

Accepted for publication March 28, 2006.

* Address correspondence to Dr Drake, Munson Professional Building, 1221 Sixth St, Suite 202, Traverse City, MI 49684 (Email: tcbulldog{at}charter.net).

PURPOSE: Sternal wire placement frequently results in glove disruption, wound contamination and personnel skin puncture. The described cutting clamp was developed to simplify sternotomy closure and reduce complications.

DESCRIPTION: Informed consent was obtained from 103 patients who underwent a variety of common cardiac surgical procedures. In each instance, once the cardiac portion of the procedure was completed, the median sternotomy was closed using standard sternal wires and the described cutting clamps. A single set of clamps was repeatedly re-sterilized and used for all cases.

EVALUATION: There were no incidents of unintentional clamp release, glove disruption or personnel skin punctures from the wire. None of the patients had clinically evident sternal wound infections or nonunion. There were no deaths. The functional attributes of the clamps remained constant throughout the study, and no significant wear was detected on the carbide inserts or other components of the clamps.

CONCLUSIONS: The sternal wire-cutting clamp simplifies sternal closure and should reduce complications.