|
|
||||||||
Ann Thorac Surg 2006;81:2135-2141
© 2006 The Society of Thoracic Surgeons
Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Seoul, Korea
Accepted for publication January 9, 2006.
* Address correspondence to Dr Kim, Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, 28 Yeun-Kun Dong, Chong-Ro Ku, Seoul 110-744, Korea. (Email: kimkb{at}snu.ac.kr).
BACKGROUND: We evaluated the early and 1-year postoperative results of grafting the skeletonized right gastroepiploic artery to the right coronary territories.
METHODS: One hundred and seventy-five patients who underwent off-pump total arterial revascularization using the skeletonized right gastroepiploic artery and bilateral internal thoracic arteries were studied. The right gastroepiploic artery was used for revascularizing the right coronary territories, and bilateral internal thoracic arteries were used for revascularizing the left coronary territories. We revised the in-situ right gastroepiploic artery graft into a composite or free graft if the flowmeter measurement suggested a competitive flow pattern. Postoperative angiographies were performed in 98.3% of the patients before discharge, and in 92.0% of the patients 1 year after surgery.
RESULTS: Hospital mortality was 0.6%. Postoperative angiography showed early patency rate of 98.3% for the right gastroepiploic artery and 99.4% for the internal thoracic artery (p = 0.352), and 1-year patency rate of 92.0% for the right gastroepiploic artery and 97.2% for the internal thoracic artery (p = 0.009). Flow competition of the right gastroepiploic artery was observed in 5.2% of the patients at the early postoperative angiography and in 6.8% of the patients 1 year after surgery. The incidence of right gastroepiploic artery graft flow competition was significantly decreased compared with that of the preflowmeter period (p = 0.036 at early angiography; p = 0.017 at 1-year angiography).
CONCLUSIONS: The skeletonized right gastroepiploic artery grafted to the right coronary territory demonstrated excellent early and 1-year patency rates. Flow competition of the in situ right gastroepiploic artery may be overcome by intraoperative revision of graft based on flow measurement.
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |