ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Mohan P. Devbhandari
Andrew J. Duncan
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Devbhandari, M. P.
Right arrow Articles by Duncan, A. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Devbhandari, M. P.
Right arrow Articles by Duncan, A. J.
Related Collections
Right arrow Valve disease

Ann Thorac Surg 2006;81:1499-1500
© 2006 The Society of Thoracic Surgeons


Case report

Acute Intraoperative Malfunction of Aortic Valve Due to Surgical Glue

Mohan P. Devbhandari, FRCS * , Qaisar Chaudhery, MRCS, Andrew J. Duncan, FRCS, CTh

Department of Cardiothoracic Surgery, Blackpool Victoria Hospital, Blackpool, United Kingdom

Accepted for publication March 1, 2005.

* Address correspondence to Dr Devbhandari, Department of Cardiothoracic Surgery, Blackpool Victoria Hospital, Whinney Hey's Rd, Blackpool, FY3 8NR United Kingdom (Email: sdevbhandari{at}aol.com).

The use of surgical glues in aortic surgery has gained wide popularity due to their hemostatic and tissue reinforcing properties. Reports of acute complications associated with application of glue are rare. We report the case of a 52-year-old fragile, steroid-dependent woman who developed acute intraoperative dysfunction of an aortic prosthetic valve due to use of BioGlue surgical adhesive. A brief literature review of the acute and long-term complications of the glue is presented.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
J. Barnard and R. Millner
A review of topical hemostatic agents for use in cardiac surgery.
Ann. Thorac. Surg., October 1, 2009; 88(4): 1377 - 1383.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. P. Goldberg and D. N. Campbell
Mechanical aortic valve dysfunction due to biological glue.
Ann. Thorac. Surg., August 1, 2009; 88(2): 671 - 672.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
D. Spielvogel, M. N. Mathur, and R. B. Griepp
Aneurysms of the Aortic Arch
Card. Surg. Adult, January 1, 2008; 3(2008): 1251 - 1276.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
M. P. Devbhandari and A. J. Duncan
Reply
Ann. Thorac. Surg., October 1, 2007; 84(4): 1426 - 1426.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Amico and C. Carbone
Intraortic Negative Pressure Suction During Glue Application
Ann. Thorac. Surg., October 1, 2007; 84(4): 1425 - 1426.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2006 by The Society of Thoracic Surgeons.