ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Belhhan Akpinar
Mustafa Guden
Ertan Sagbas
Ilhan Sanisoglu
Baris Caynak
Zehra Bayramoglu
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Akpinar, B.
Right arrow Articles by Bayramoglu, Z.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Akpinar, B.
Right arrow Articles by Bayramoglu, Z.
Related Collections
Right arrow Valve disease

Ann Thorac Surg 2006;81:1095-1098
© 2006 The Society of Thoracic Surgeons


New technology

Robotic-Enhanced Totally Endoscopic Mitral Valve Repair and Ablative Therapy

Belhhan Akpinar, MD * , Mustafa Guden, MD, Ertan Sagbas, MD, Ilhan Sanisoglu, MD, Baris Caynak, MD, Zehra Bayramoglu, MD

Department of Cardiac Surgery, Florence Nightingale Hospital, Istanbul, Turkey

Accepted for publication September 12, 2005.

* Address correspondence to Dr Akpinar, Department of Cardiac Surgery, Florence Nightingale Hospital, Abidei Hurriyet Cad No. 290, Sisli-Istanbul, PB 80220 Turkey (Email: belh{at}tnn.net).

PURPOSE: The aim of this article was to assess the feasibility of totally closed robotic mitral valve repair and ablative therapy.

DESCRIPTION: Two patients with mitral valve disease and permanent atrial fibrillation underwent the combined procedure using the da Vinci robotic system (Intuitive Surgical, Sunnyvale, CA). Radiofrequency ablation was performed using the Cardioblate XL unipolar pen (Medtronic Inc, Minneapolis, MN). One patient underwent mitral commissurotomy and the other commissurotomy and Reed annuloplasty.

EVALUATION: There were no procedure-related complications. Sinus rhythm was established in both patients after the operation, and transesophageal echocardiography revealed competent mitral valves without residual gradients.

CONCLUSIONS: Robotic-enhanced mitral valve repair and ablation proved feasible in both patients with good clinical outcome. The described combined method may find broader application in a selected group of patients with the continuing evolution in technology.




This article has been cited by other articles:


Home page
ICVTSHome page
P. Modi, E. Rodriguez, and W. R. Chitwood Jr.
Robot-assisted cardiac surgery
Interactive CardioVascular and Thoracic Surgery, September 1, 2009; 9(3): 500 - 505.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S.-i. Sakamoto, R. K. Voeller, S. J. Melby, S. C. Lall, N.-l. Chang, R. B. Schuessler, and R. J. Damiano Jr.
Surgical ablation for atrial fibrillation: The efficacy of a novel bipolar pen device in the cardioplegically arrested and beating heart.
J. Thorac. Cardiovasc. Surg., November 1, 2008; 136(5): 1295 - 1301.