ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Sary F. Aranki
Prem S. Shekar
Afshin Ehsan
Gregory S. Couper
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Aranki, S. F.
Right arrow Articles by Couper, G. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Aranki, S. F.
Right arrow Articles by Couper, G. S.
Related Collections
Right arrow Coronary disease

Ann Thorac Surg 2005;80:1091-1095
© 2005 The Society of Thoracic Surgeons


New technology

Evaluation of the Enclose Proximal Anastomosis Device in Coronary Artery Bypass Grafting

Sary F. Aranki, MD * , Prem S. Shekar, MD, Afshin Ehsan, MD, Margaretta Byrne-Taft, MPH, Gregory S. Couper, MD

Division of Cardiac Surgery, Brigham and Women’s Hospital, Boston, Massachussetts

Accepted for publication October 22, 2004.

* Address reprint requests to Dr Aranki, Brigham and Women’s Hospital, 75 Francis St, Boston, MA 02115. (Email: saranki{at}partners.org).

PURPOSE: Minimal manipulation of the ascending aorta during coronary artery bypass grafting may reduce the incidence of adverse perioperative events related to atheroembolic events. The objective of this study was to evaluate a new proximal anastomotic device (Novare Enclose device [Novare Surgical Systems, Cupertino, CA]).

DESCRIPTION: Over a 23-month period, a total of 76 proximal anastomoses were performed in 50 patients (40 males and 10 females; mean age, 74.36 years). In 45 patients, the proximal anastomosis was constructed before the distal (25 off-pump and 20 on-pump), and in 5 patients the proximal anastomosis was constructed on cardiopulmonary bypass because of diseased ascending aortas.

EVALUATION: The average time per anastomosis was <8 minutes. There were no device related complications. There were no atheroembolic complications in this cohort of patients. One patient underwent cardiac catheterization postoperatively, and the proximal vein anastomosis in this patient was widely patent.

CONCLUSIONS: The Novare Enclose proximal anastomotic device (Novare Surgical Systems) appears to be safe and effective as a tool for proximal anastomosis within a reasonable time period and is comparable with accepted techniques.




This article has been cited by other articles:


Home page
CirculationHome page
T. P. Martens, M. Argenziano, and M. C. Oz
New Technology for Surgical Coronary Revascularization
Circulation, August 8, 2006; 114(6): 606 - 614.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2005 by The Society of Thoracic Surgeons.