ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Motomi Shiono
Yukiyasu Sezai
Akira Sezai
Mitsumasa Hata
Nanao Negishi
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shiono, M.
Right arrow Articles by Negishi, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shiono, M.
Right arrow Articles by Negishi, N.
Related Collections
Right arrow Valve disease

Ann Thorac Surg 2005;80:204-209
© 2005 The Society of Thoracic Surgeons


Original article: Cardiovascular

Long-Term Results of the Cloth-Covered Starr-Edwards Ball Valve

Motomi Shiono, MD, PhD*, Yukiyasu Sezai, MD, PhD, Akira Sezai, MD, PhD, Mitsumasa Hata, MD, PhD, Mitsuru Iida, MD, PhD, Nanao Negishi, MD, PhD

Department of Cardiovascular Surgery, Nihon University School of Medicine, Tokyo, Japan

Accepted for publication February 1, 2005.

* Address reprint requests to Dr Shiono, Department of Cardiovascular Surgery, Nihon University School of Medicine, 30-1 Oyaguchi-kamimachi, Itabashi-ku, Tokyo 173-8610, Japan (Email: mshiono{at}med.nihon-u.ac.jp).

BACKGROUND: Between June 1968 and March 1977, Starr-Edwards cloth-covered ball valves were exclusively implanted, in a total of 74 patients at our institution, on a routine basis.

METHODS: The retrospective postoperative follow-up rate was 84.5%, for up to 36 years in mitral valve patients (982.5 patient-years); and 81.3%, for up to 34 years in aortic valve patients (282.0 patient-years). Among 66 operative survivors, 20 patients required reoperation due to valve-related complications. Mortality and morbidity after valve replacement was reviewed, and excised valves were examined.

RESULTS: Survival rates after 10, 20, and 30 years were 74.6%, 64.1%, and 31.2%, respectively, after mitral valve replacement, and 62.5%, 50.0%, and 43.8%, respectively, after aortic valve replacement. Freedom from all valve-related complications, respectively after 10, 20, and 30 years, was 70.5%, 55.9%, and 46.4% after mitral valve replacement, and 56.2%, 37.5%, and 31.2% after aortic valve replacement. Cloth wear or pannus overgrowth was observed in all excised prostheses. Remarkable orifice tear was observed in mitral valves that were more than 20 years old. Pannus overgrowth on the studs contributed to prosthetic regurgitation in the older valves. Concomitant valve procedures were frequently required for valve-related complications or other aggravated valve lesions in the mitral position during the follow-up period.

CONCLUSIONS: Early diagnosis of valve dysfunction and the decision to reoperate are important to improve the long-term results for surviving patients who have received a cloth-covered Starr-Edwards valve, especially in the mitral position.




This article has been cited by other articles:


Home page
Card Surg AdultHome page
R. W. Emery, A. M. Emery, A. Knutsen, and G. V. Raikar
Aortic Valve Replacement with a Mechanical Cardiac Valve Prosthesis
Card. Surg. Adult, January 1, 2008; 3(2008): 841 - 856.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2005 by The Society of Thoracic Surgeons.