ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Scott A. LeMaire
Taehee Won
Lori D. Conklin
Joseph S. Coselli
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by LeMaire, S. A.
Right arrow Articles by Coselli, J. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by LeMaire, S. A.
Right arrow Articles by Coselli, J. S.
Related Collections
Right arrow Great vessels

Ann Thorac Surg 2005;80:106-111
© 2005 The Society of Thoracic Surgeons


Original article: Cardiovascular

The Threat of Adhesive Embolization: BioGlue Leaks Through Needle Holes in Aortic Tissue and Prosthetic Grafts

Scott A. LeMaire, MD*, Stacey A. Carter, BA, Taehee Won, MD, Xinwen Wang, MD, PhD, Lori D. Conklin, MD, Joseph S. Coselli, MD

The Texas Heart Institute at St. Luke’s Episcopal Hospital and The Michael E. DeBakey Department of Surgery, Division of Cardiothoracic Surgery, Baylor College of Medicine, Houston, Texas

Accepted for publication February 1, 2005.

* Address reprint requests to Dr LeMaire, One Baylor Plaza, BCM 390, Houston, TX 77030 (Email: slemaire{at}bcm.tmc.edu).

Presented at the Fortieth Annual Meeting of The Society of Thoracic Surgeons, San Antonio, TX, Jan 26–28, 2004.

BACKGROUND: BioGlue Surgical Adhesive (CryoLife, Inc, Kennesaw, GA) is used to reinforce anastomoses during cardiovascular operations. Previous reports have raised concerns that adhesives may leak through suture-line needle holes and that resulting intraluminal glue may embolize. The purpose of this study was to determine if BioGlue leaks through anastomotic needle holes in aortic tissue and two common prosthetic graft materials.

METHODS: Polypropylene suture was used to create end-to-end anastomoses in gelatin-sealed woven polyester grafts (n = 45), expanded polytetrafluoroethylene (ePTFE) grafts (n = 45), and fresh porcine aortas (n = 45). An additional 45 anastomoses were created in ePTFE grafts using ePTFE sutures. The outer surface of each anastomosis was covered with BioGlue. Anastomoses underwent inspection with direct magnification or histology.

RESULTS: BioGlue leaked through needle holes and into the lumen in 10% of anastomoses (18 of 180). Leaks were significantly more common in fresh aorta (10 of 45, 22%) than in prosthetic grafts (8 of 135, 6%; p = 0.003). Suture size did not significantly affect the incidence of leak. The use of ePTFE sutures did not eliminate BioGlue leakage. Prosthetic graft leaks created discreet round adhesive particles. In contrast, aortic tissue leaks resulted in thin, friable flakes of glue extending along the intimal surface. Aortic histology confirmed that BioGlue reached the vessel lumen via the suture channels.

CONCLUSIONS: BioGlue leaked through the needle holes in fresh aortic tissue and prosthetic grafts. Intraluminal adhesive particles were easily dislodged, supporting concerns regarding embolization. The potential for adhesive embolization should be a factor when considering the relative risks and benefits of using BioGlue.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
J. Barnard and R. Millner
A review of topical hemostatic agents for use in cardiac surgery.
Ann. Thorac. Surg., October 1, 2009; 88(4): 1377 - 1383.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. P. Goldberg and D. N. Campbell
Mechanical aortic valve dysfunction due to biological glue.
Ann. Thorac. Surg., August 1, 2009; 88(2): 671 - 672.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
K. J. Zehr
Reply.
Ann. Thorac. Surg., September 1, 2008; 86(3): 1056 - 1057.
[Full Text] [PDF]


Home page
Card Surg AdultHome page
D. Spielvogel, M. N. Mathur, and R. B. Griepp
Aneurysms of the Aortic Arch
Card. Surg. Adult, January 1, 2008; 3(2008): 1251 - 1276.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
K. J. Zehr
Use of Bovine Albumin-Glutaraldehyde Glue in Cardiovascular Surgery
Ann. Thorac. Surg., September 1, 2007; 84(3): 1048 - 1052.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. J. Van Nooten, P. Somers, R. Forsyth, K. Narine, Y. Van Belleghem, S. Jacobs, and F. De Somer
Autologous glue: Part of the sticky mystery unraveled
J. Thorac. Cardiovasc. Surg., August 1, 2007; 134(2): 415 - 423.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
Z. Mitrev, V. Belostotskii, and N. Hristov
Suture line reinforcement using suction-assisted bioglue application during surgery for acute aortic dissection
Interactive CardioVascular and Thoracic Surgery, April 1, 2007; 6(2): 147 - 149.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. Tansley, F. Al-Mulhim, E. Lim, G. Ladas, and P. Goldstraw
A prospective, randomized, controlled trial of the effectiveness of BioGlue in treating alveolar air leaks
J. Thorac. Cardiovasc. Surg., July 1, 2006; 132(1): 105 - 112.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2005 by The Society of Thoracic Surgeons.