ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Kerem M. Vural
Aysegul Kunt
Erol Sener
Oguz Tasdemir
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Vural, K. M.
Right arrow Articles by Tasdemir, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vural, K. M.
Right arrow Articles by Tasdemir, O.
Related Collections
Right arrow Coronary disease

Ann Thorac Surg 2005;79:814-818
© 2005 The Society of Thoracic Surgeons


Original article: Cardiovascular

Off-Pump, In Situ Internal Thoracic Artery Grafting: A Durable Treatment for Single-Vessel Coronary Artery Disease

Kerem M. Vural, MD*, Zafer H. Iscan, MD, Aysegul Kunt, MD, Erol Sener, MD, Oguz Tasdemir, MD

Department of Cardiovascular Surgery, Yuksek Ihtisas Hospital of Turkey, Ankara, Turkey

Accepted for publication August 23, 2004.

* Address reprint requests to Dr Vural, N. Tandogan cad. 5/6 Kavaklidere, 06540 Ankara, Turkey (E-mail: kvural{at}tr.net).

BACKGROUND: The value of off-pump in situ left internal thoracic artery to left anterior descending coronary artery bypass grafting in single-vessel coronary artery disease was assessed by long-term angiographic and clinical data.

METHODS: One-hundred three randomly selected patients (87 male, 16 female; mean age, 57.4 ± 10.5 years) underwent postoperative angiographic control after an average postoperative period of 4.8 ± 2.9 years (up to 8.2 years; a total of 490 patient-years).

RESULTS: Fifty-five patients (52%) were asymptomatic, whereas 31 (30%) had anginalike chest pain. Ninety-seven patients (94.2%) were in New York Heart Association class I or II. Five-year angina-free survival was 81% ± 5%. Of 103 left internal thoracic arteries assessed, 99 were patent (overall patency, 96.1%). All four cases having occluded grafts had mild native vessel stenoses (<80%) before operation. The patency rate was 99% ± 1% at 3 years, and 93% ± 4% at 5 years. The left ventricular segmental wall motion score of the left anterior descending coronary arterial distribution improved from 4.1 ± 1.1 to 3.7 ± 0.9 (p = 0.001). Consequently, 15 patients (15%) underwent secondary revascularization (11 interventional and 4 surgical) 4.8 ± 2.1 years after the primary operation. The most frequent indication for interventional revascularization was atherosclerotic progression in systems other than left anterior descending artery. The cases with graft occlusion were treated surgically. Five-year freedom from interventional or surgical repeat revascularization was 91% ± 4%.

CONCLUSIONS: In addition to the well-documented safety and reliability, off-pump in situ left internal thoracic artery grafting is also a durable treatment for isolated left anterior descending artery disease, in both clinical and angiographic terms.