ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Mirko Doss
Sven Martens
Jeffrey P. Wood
Gerhard Wimmer-Greinecker
Anton Moritz
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Doss, M.
Right arrow Articles by Moritz, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Doss, M.
Right arrow Articles by Moritz, A.
Related Collections
Right arrow Valve disease

Ann Thorac Surg 2005;79:682-685
© 2005 The Society of Thoracic Surgeons


New technology

Aortic Leaflet Replacement With the New 3F Stentless Aortic Bioprosthesis

Mirko Doss, MD*,a, Sven Martens, MDa, Jeffrey P. Wood, MDa, Aleksandra Miskovic, MDa, Triantafyllia Christodouloua, Gerhard Wimmer-Greinecker, MDa, Anton Moritz, MDa

a Department of Thoracic and Cardiovascular Surgery, Johann Wolfgang Goethe University, Frankfurt/Main, Germany

Accepted for publication October 28, 2003.

* Address reprint requests to Dr Doss, Department of Thoracic and Cardiovascular Surgery, Johann Wolfgang Goethe-University Frankfurt/Main, Theodor-Stern-Kai 7, Frankfurt/Main 60590, Germany
mirkodoss{at}aol.com

PURPOSE: Clinical trials with the new 3F stentless aortic bioprosthesis began October 2001, and as one of the first centers to implant this prosthesis in humans, we would like to present our experiences with this new device.

DESCRIPTION: The 3F aortic bioprosthesis is a stentless biological heart valve fabricated from three equal leaflets of equine pericardium, assembled in a tubular shape, and implanted in the native aortic root to replace the patient's diseased aortic leaflets. Between January 2002 and August 2002, 24 3F aortic bioprostheses were implanted at our institution. Effective orifice area, mean gradients, and ejection fraction were evaluated by echocardiography at discharge and at 12-month follow-ups after surgery.

EVALUATION: At 12-month follow-ups, the 3F bioprosthesis showed a good hemodynamic performance with a significant drop of mean gradients to 10.3 mm Hg, a mean effective orifice area of 1.7 cm2, and a mean ejection fraction of 61.5%.

CONCLUSIONS: The clinical performance of the new 3F aortic bioprosthesis is comparable with regular stentless aortic valves. However its unique design facilitates implantation.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
S. Martens, A. Ploss, S. Sirat, A. Miskovic, A. Moritz, and M. Doss
Sutureless Aortic Valve Replacement With the 3f Enable Aortic Bioprosthesis.
Ann. Thorac. Surg., June 1, 2009; 87(6): 1914 - 1917.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
W. A. Goetz, T. E. Tan, K. H. Lim, S. L. H. Salgues, N. Grousson, F. Xiong, Y. L. Chua, and J. H. Yeo
Truly stentless molded autologous pericardial aortic valve prosthesis with single point attached commissures in a sheep model
Eur. J. Cardiothorac. Surg., April 1, 2008; 33(4): 548 - 553.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
P. Stelzer
Stentless Aortic Valve Replacement: Porcine and Pericardial
Card. Surg. Adult, January 1, 2008; 3(2008): 915 - 934.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
D. Grandmougin and G. Fayad
Implantation of a modified freestyle valve with a single inflow suture line: technical patterns and advantages.
Ann. Thorac. Surg., September 1, 2006; 82(3): 1128 - 1130.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
W. A. Goetz, K. H. Lim, R. Ibled, N. Grousson, S. L. H. Salgues, and J. H. Yeo
Forces at single point attached commissures (SPAC) in pericardial aortic valve prosthesis
Eur. J. Cardiothorac. Surg., February 1, 2006; 29(2): 150 - 155.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2005 by The Society of Thoracic Surgeons.