Ann Thorac Surg 2004;78:2057-2062
© 2004 The Society of Thoracic Surgeons
a Department of Thoracic and Cardiovascular Surgery, Seoul, South Korea
b Department of Anesthesiology, Clinical Research Institute, Seoul National University Hospital, Seoul, South Korea
Accepted for publication May 19, 2004.
* Address reprint requests to Dr Kim, Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, 28 Yeun-Kun Dong, Chong-Ro Ku, Seoul 110744, South Korea
kimkb{at}snu.ac.kr
BACKGROUND: Displacement of the heart to expose posterior vessels during off-pump coronary artery bypass may cause hemodynamic derangement. The aims of this study were (1) to elucidate the hemodynamic changes during off-pump coronary artery bypass for the obtuse marginal branch (OM) of the left circumflex artery; and (2) to compare the hemodynamic changes caused by a deep pericardial suture technique with those caused by a vacuum-assisted apical suction device for displacement of the heart.
METHODS: Hemodynamic changes during posterior vessel off-pump coronary artery bypass were studied in a prospective randomized manner. A deep pericardial suture technique (group 1, n = 10) or a vacuum-assisted apical suction device (group 2, n = 10) was used to facilitate the exposure of the OM. Hemodynamic variables such as cardiac index, stroke volume index (SVI), mean arterial pressure, mean pulmonary artery pressure, central venous pressure, pulmonary capillary wedge pressure, heart rate, systemic vascular resistance, pulmonary vascular resistance, left ventricular stroke work index, and right ventricular stroke work index were monitored during off-pump coronary artery bypass. Hemodynamic data were obtained before revascularization of the left anterior descending coronary artery at a baseline (T0), 3 minutes after heart displacement for revascularization of OM (T1), 3 minutes after the beginning of OM grafting (T2), and 3 minutes after the completion of OM grafting and heart repositioning (T3).
RESULTS: There were no significant differences in the baseline hemodynamic variables (T0) between the two groups. In group 1, SVI, cardiac index, left ventricular stroke work index, and right ventricular stroke work index decreased significantly, and central venous pressure and pulmonary capillary wedge pressure increased significantly, during displacement of the heart (T1, p < 0.05). In group 2, SVI decreased significantly, and central venous pressure, pulmonary capillary wedge pressure, and mean pulmonary artery pressure increased significantly during displacement of the heart (T1, p < 0.05). The percent changes of cardiac index, SVI, and right ventricular stroke work index during OM grafting (T2) in comparison with baseline values (T0) were significantly larger in group 1 than in group 2 (cardiac index, 73% ± 12% versus 90% ± 11%; SVI, 69% ± 12% versus 86% ± 8%; right ventricular stroke work index, 30% ± 17% versus 71% ± 25%, in groups 1 versus 2, respectively; p < 0.05).
CONCLUSIONS: Displacement of the heart using either a deep pericardial suture technique or a vacuum-assisted apical suction device caused a significant decrease in SVI. The hemodynamic changes during OM grafting were smaller when using a vacuum-assisted apical suction device.
This article has been cited by other articles:
![]() |
A. L. Shroyer, F. L. Grover, B. Hattler, J. F. Collins, G. O. McDonald, E. Kozora, J. C. Lucke, J. H. Baltz, D. Novitzky, and the Veterans Affairs Randomized On/Off Bypass (ROO On-Pump versus Off-Pump Coronary-Artery Bypass Surgery N. Engl. J. Med., November 5, 2009; 361(19): 1827 - 1837. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. J. George, E. I. Kapetanakis, K. Dhadwal, S. Al-Ruzzeh, E. Rigopoulou, M. Bulanade, T. Athanasiou, and M. Amrani A three-dimensional echocardiographic comparison of a deep pericardial stitch versus an apical suction device for heart positioning during beating heart surgery Eur. J. Cardiothorac. Surg., October 1, 2007; 32(4): 604 - 610. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Dzwonczyk, C. L. d. Rio, C. Sai-Sudhakar, J. H. Sirak, R. E. Michler, B. Sun, N. Kelbick, and M. B. Howie Vacuum-assisted apical suction devices induce passive electrical changes consistent with myocardial ischemia during off-pump coronary artery bypass graft surgery Eur. J. Cardiothorac. Surg., December 1, 2006; 30(6): 873 - 876. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Tabata, S. Takanashi, T. Horai, T. Fukui, and Y. Hosoda Emergency conversion in off-pump coronary artery bypass grafting Interactive CardioVascular and Thoracic Surgery, October 1, 2006; 5(5): 555 - 559. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. L. Fernandez, J. B. Garcia-Bengochea, J. Alvarez, L. F. Perez, J. M. Suarez, J. Forteza, J. Cortes, and A. Martinez Apical suction leads to severe ischemia of the ventricular apex. Eur. J. Cardiothorac. Surg., April 1, 2006; 29(4): 506 - 510. [Abstract] [Full Text] [PDF] |
||||