ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Yoichi Kameda
Tohru Mori
Shigeki Taniguchi
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kameda, Y.
Right arrow Articles by Taniguchi, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kameda, Y.
Right arrow Articles by Taniguchi, S.
Related Collections
Right arrow Valve disease

Ann Thorac Surg 2004;78:1827-1829
© 2004 The Society of Thoracic Surgeons


Case report

Aortopulmonary Fistula Due to Perforation of the Aortic Wall of a Freestyle Stentless Valve

Yoichi Kameda, MD*,a, Kazumi Mizuguchi, MDa, Toshiyuki Kuwata, MDa, Tohru Mori, MDa, Shigeki Taniguchi, MDb

a Department of Cardiovascular Surgery, Ishinkai Yao General Hospital, Yao, Osaka, Japan
b Department of Thoracic and Cardiovascular Surgery, Nara Medical University, Kashihara, Nara, Japan

Accepted for publication July 21, 2003.

* Address reprint requests to Dr Kameda, Department of Cardiovascular Surgery, Nara Medical University, Shijo-Cho 840, Kashihara, Nara 634-8522, Japan
ykameda{at}naramed-u.ac.jp

Aortopulmonary fistula occurring as a result of a rupture of the aortic wall of a stentless valve has not been previously reported. A 71-year-old woman suffered aortopulmonary fistula 15 months after replacement of the aortic root with a Freestyle stentless valve (Medtronic, Inc, Minneapolis, MN) and Dacron graft extension to replace the aortic valve and the ascending aorta to the aortic arch. We describe the successful repair of the fistula and simultaneous mitral valve replacement. The cause of deterioration of the aortic wall of the stentless valve, which gradually developed and ruptured, may have been primarily structural injury at the previous operation, with additional insult from the surgical adhesive used.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
Y. Takami, H. Masumoto, and B. Fyfe-Kirschner
Late Disruption of a Freestyle Stentless Bioprosthesis Used for Repair of Sinus of Valsalva Aneurysm of Noncoronary Cusp
Ann. Thorac. Surg., June 1, 2007; 83(6): 2210 - 2213.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
N. Ozaki, Y. Hino, Y. Hanafusa, T. Yamashita, K. Okada, T. Tsukube, and Y. Okita
Perforation of the Valsalva Sinus After Implantation of Medtronic Freestyle Aortic Bioprosthesis
Ann. Thorac. Surg., December 1, 2006; 82(6): 2282 - 2285.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
M. Mukadam, J. Barraclough, P. Riley, and R. Bonser
Acquired aorto-pulmonary artery fistula following proximal aortic surgery
Interactive CardioVascular and Thoracic Surgery, October 1, 2005; 4(5): 388 - 390.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2004 by The Society of Thoracic Surgeons.