ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Ujjwal K. Chowdhury
Pankaj K. Mishra
Rajesh Sharma
Balram Airan
Anil Bhan
Panangipalli Venugopal
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Chowdhury, U. K.
Right arrow Articles by Venugopal, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Chowdhury, U. K.
Right arrow Articles by Venugopal, P.
Related Collections
Right arrow Congenital - cyanotic

Ann Thorac Surg 2004;78:658-665
© 2004 The Society of Thoracic Surgeons


Original article: cardiovascular

Postoperative assessment of the univentricular repair by dynamic radionuclide studies

Ujjwal K. Chowdhury, MCh, DNBa*, Pankaj K. Mishra, MCha, Rajesh Sharma, MCha, Balram Airan, MCha, Ganapathy K. Subramaniam, MSa, Shyam S. Kothari, DM, FACCb, Anil Bhan, MCha, Chetan D. Patel, DRM, DNBc, Panangipalli Venugopal, MCha

a Departments of Cardiothoracic and Vascular Surgery, Cardiothoracic Centre, All India Institute of Medical Sciences, New Delhi, India
b Department of Cardiology, Cardiothoracic Centre, All India Institute of Medical Sciences, New Delhi, India
c Department of Nuclear Medicine, Cardiothoracic Centre, All India Institute of Medical Sciences, New Delhi, India

Accepted for publication January 9, 2004.

* Address reprint requests to Dr Chowdhury, Department of Cardiothoracic and Vascular Surgery, All India Institute of Medical Sciences, Ansari Nagar, New Delhi-110029, India
e-mail: ujjwalchow{at}rediffmail.com

BACKGROUND: The purpose of this investigation was to determine the role of radionuclide studies in evaluating postoperative Fontan hemodynamics and to quantify its diagnostic accuracy.

METHODS: One hundred five patients (105), aged 11 months to 35 years old, who had undergone univentricular repair, underwent first-pass and multigated acquisition scan 1 month to 10 years after univentricular repair. Forty-five patients with evidence of Fontan failure underwent radionuclide studies using Technetium-99 m as well as cardiac catheterization (group 1). The remaining sixty randomly selected patients with excellent functional status received radionuclide studies alone (group 2). The receiver operating characteristic curve analysis was done to quantify the diagnostic accuracy of the first-pass study.

RESULTS: There was paradoxical filling of the right lung after femoral injection in all cases of tunnel or conduit obstruction. A first-pass transit time of 16 to 25 seconds (mean ± standard deviation [SD] = 18.82 ± 2.69) was always associated with Fontan failure and high right atrial pressure (range = 20 to 24 mm Hg, mean ± SD = 22.02 ± 1.58). A first-pass transit time of 16 seconds was associated with a sensitivity of 100% and a specificity of 93.33%. The predictive accuracy of a positive or negative result was 91.8% and 100% respectively. The area measured under the receiver operating characteristic curve indicates that 99.41% (SE ± 0.0035) of the time, the value of first-pass time is higher for the Fontan failure group (group 1) compared to the normal group (group 2; p = 0.000).

CONCLUSIONS: Our data indicate that Fontan circuit can be reliably evaluated for both anatomic and functional flaws by radionuclide studies; radionuclide first-pass time may be used to predict the chances of Fontan failure postoperatively as well as its presence; and in the presence of atrial fibrillation with fast ventricular rate, analysis using first-pass radionuclide may be impossible and gated equilibrium radionuclide angiocardiography may be the preferred method. Inspection of the systemic ventricular time-activity curve is of crucial importance in this regard.