ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Jean-Paul Remadi
Henri J. Poulain
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Remadi, J.-P.
Right arrow Articles by Poulain, H. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Remadi, J.-P.
Right arrow Articles by Poulain, H. J.
Related Collections
Right arrow Extracorporeal circulation

Ann Thorac Surg 2004;77:2172-2175
© 2004 The Society of Thoracic Surgeons


New technology

Clinical experience with the mini-extracorporeal circulation system: an evolution or a revolution?

Jean-Paul Remadi, MDa*, Paul Marticho, MDb, Irina Butoi, MDb, Zava Rakotoarivelo, MDa, Faouzi Trojette, MDa, Amar Benamar, MDa, Sadek Beloucif, MDa, Dominique Foure, MDb, Henri J. Poulain, MDa

a Cardiovascular Surgery Unit, Amiens, France
b Anesthesiology Department, South Hospital, Amiens, France

Accepted for publication May 20, 2003.

* Address reprint requests to Dr Remadi, Centre Hopitalier Universitaire D'Amiens, Service de Chirurgie Cardique, Groupe Hopitalier Sud, Amiens Cedex 1 80054, France.
e-mail: jpremadi{at}aol.com

Abstract

PURPOSE: We studied a cohort of 150 patients operated on with a new cardiopulmonary bypass (CPB) system. This is the mini-extracorporeal circulation (MECC) system.

DESCRIPTION: The MECC is a fully heparin coated closed-loop CPB system that includes a centrifugal pump and has a priming volume of 450 mL. Between March 2001 and September 2002, 150 consecutive patients were operated on using the mini-CPB (MECC) method. This includes 105 coronary artery bypass graft and 45 aortic valve replacement patients. The median age was 66.7 ± 10.7 years with a gender ratio of 3.27 males to 1 female.

EVALUATION: The 30-day operative mortality was 1.3%. The hemoglobin concentration was stable and perioperative transfusion was needed in only 6% of all patients. The renal and neuropsychiatric complications were less than 1%.

CONCLUSIONS: In our experience, the MECC system is a reliable new concept for CPB with good clinical results.




This article has been cited by other articles:


Home page
ICVTSHome page
G. F.V. Panday, S. Fischer, A. Bauer, D. Metz, J. Schubel, N. E. Shouki, T. Eberle, and H. Hausmann
Minimal extracorporeal circulation and off-pump compared to conventional cardiopulmonary bypass in coronary surgery
Interactive CardioVascular and Thoracic Surgery, November 1, 2009; 9(5): 832 - 836.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Ranucci, A. Balduini, A. Ditta, A. Boncilli, and S. Brozzi
A Systematic Review of Biocompatible Cardiopulmonary Bypass Circuits and Clinical Outcome
Ann. Thorac. Surg., April 1, 2009; 87(4): 1311 - 1319.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Yilmaz, A. Rehman, U. Sonker, and G. T.L. Kloppenburg
Minimal access aortic valve replacement using a minimal extracorporeal circulatory system.
Ann. Thorac. Surg., March 1, 2009; 87(3): 720 - 725.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. P. Sakwa, R. W. Emery, F. L. Shannon, J. M. Altshuler, D. Mitchell, D. Zwada, and A. R. Holter
Coronary artery bypass grafting with a minimized cardiopulmonary bypass circuit: a prospective, randomized trial.
J. Thorac. Cardiovasc. Surg., February 1, 2009; 137(2): 481 - 485.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
L. K. Ti, B.-L. Goh, P.-S. Wong, P. Ong, S.-G. Goh, and C.-N. Lee
Comparison of Mini-Cardiopulmonary Bypass System With Air-Purge Device to Conventional Bypass System
Ann. Thorac. Surg., March 1, 2008; 85(3): 994 - 1000.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J.-P. Remadi
Invited Commentary
Ann. Thorac. Surg., March 1, 2008; 85(3): 1000 - 1001.
[Full Text] [PDF]


Home page
PerfusionHome page
P. Farneti, S Sbrana, D Spiller, A. Cerillo, F Santarelli, D Di Dario, P. Del Sarto, and M Glauber
Reduction of blood coagulation and monocyte-platelet interaction following the use of a minimal extracorporeal circulation system (Synergy(R)) in coronary artery bypass grafting (CABG)
Perfusion, January 1, 2008; 23(1): 49 - 56.
[Abstract] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
C. McKay
Perfusion Approaches to Blood Conservation
Seminars in Cardiothoracic and Vascular Anesthesia, December 1, 2007; 11(4): 252 - 255.
[Abstract] [PDF]


Home page
CirculationHome page
V. Mazzei, G. Nasso, G. Salamone, F. Castorino, A. Tommasini, and A. Anselmi
Prospective Randomized Comparison of Coronary Bypass Grafting With Minimal Extracorporeal Circulation System (MECC) Versus Off-Pump Coronary Surgery
Circulation, October 16, 2007; 116(16): 1761 - 1767.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. A.J.M. Huybregts, A. M. Morariu, G. Rakhorst, S. R. Spiegelenberg, H. W.A. Romijn, R. de Vroege, and W. van Oeveren
Attenuated Renal and Intestinal Injury After Use of a Mini-Cardiopulmonary Bypass System
Ann. Thorac. Surg., May 1, 2007; 83(5): 1760 - 1766.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Beghi, F. Nicolini, A. Agostinelli, B. Borrello, A. M. Budillon, F. Bacciottini, M. Friggeri, A. Costa, L. Belli, L. Battistelli, et al.
Mini-Cardiopulmonary Bypass System: Results of a Prospective Randomized Study
Ann. Thorac. Surg., April 1, 2006; 81(4): 1396 - 1400.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
U. Abdel-Rahman, F. Ozaslan, P. S. Risteski, S. Martens, A. Moritz, A. Al Daraghmeh, H. Keller, and G. Wimmer-Greinecker
Initial Experience With a Minimized Extracorporeal Bypass System: Is There a Clinical Benefit?
Ann. Thorac. Surg., July 1, 2005; 80(1): 238 - 243.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
W J van Boven, W B Gerritsen, F G Waanders, F J Haas, and L P Aarts
Mini extracorporeal circuit for coronary artery bypass grafting: initial clinical and biochemical results: A comparison with conventional and off-pump coronary artery bypass grafts concerning global oxidative stress and alveolar function
Perfusion, July 1, 2004; 19(4): 239 - 246.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2004 by The Society of Thoracic Surgeons.