ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Matthias Loebe
Vera Regitz-Zagrosek
Roland Hetzer
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Potapov, E. V.
Right arrow Articles by Hetzer, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Potapov, E. V.
Right arrow Articles by Hetzer, R.
Related Collections
Right arrow Mechanical Circulatory Assistance

Ann Thorac Surg 2004;77:869-874
© 2004 The Society of Thoracic Surgeons


Original article: cardiovascular

Clinical significance of PlA polymorphism of platelet GP IIb/IIIa receptors during long-term VAD support

Evgenij V. Potapov, MDa*, Stanislav Ignatenko, MDa, Boris A. Nasseri, MDa, Matthias Loebe, MD, PhDd, Cornelia Harkea, Martin Bettmann, MDa, Anke Doller, MDb,c, Vera Regitz-Zagrosek, MD, PhDb,c, Roland Hetzer, MD, PhDa

a Departments of Cardiothoracic and Vascular Surgery, Berlin, Germany
b Cardiovascular Disease in Women, Deutsches Herzzentrum Berlin, Germany
c Charité, Campus Virchow Klinikum, Humboldt University, Berlin, Germany
d Michael E. DeBakey Department of Surgery, Division of Transplantation and Assist Devices, Baylor College of Medicine, Houston, Texas, USA

Accepted for publication August 19, 2003.

* Address reprint requests to Dr Potapov, Deutsches Herzzentrum Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
e-mail: potapov{at}dhzb.de

BACKGROUND: Although bleeding and thromboembolism remain major complications after implantation of ventricular assist devices (VADs), no standard anticoagulation protocols are available. Genetic polymorphism of platelet glycoprotein IIb/IIIa may contribute to the development of complications. The present study demonstrates a relationship between the PlA genotype and postoperative complications in patients implanted with pulsatile and axial flow VADs.

METHODS: The PlA genotype was determined in 41 consecutive patients treated with a VAD who received anticoagulation with phenprocoumon and aspirin. Pulsatile Novacor (Novacor Corp, Oakland, CA) and Berlin Heart VADs (Berlin Heart, Berlin, Germany) were implanted in 28 patients and the axial flow MicroMed DeBakey VAD (MicroMed Technology, Inc, Houston, TX) in 13. The relationship between the PlA genotype, the anticoagulation regime, and bleeding and thromboembolic events was analyzed.

RESULTS: There were no differences between patients with the A1A1 and A1A2 genotype regarding demographic characteristics, weight, or infection episodes. The international normalized ratio (INR), platelet activation tests, and doses of aspirin and dipyridamol before events were similar in both groups. Patients with the A1A1 genotype developed more bleeding complications (39% vs 0%, p = 0.021), while patients with the A1A2 genotype showed a tendency toward more thromboembolic events (13% vs 30%, p = 0.33). With regard to different types of VAD, patients with the axial flow DeBakey VAD and the A1A1 genotype developed significantly more bleeding complications (70% vs 0%, p = 0.033).

CONCLUSIONS: In patients with a long-term VAD determination of PlA polymorphism and subsequent adjustment of the anticoagulation regime may lead to a reduction of bleeding and thromboembolic complications.




This article has been cited by other articles:


Home page
ChestHome page
S. Schulman, R. J. Beyth, C. Kearon, and M. N. Levine
Hemorrhagic Complications of Anticoagulant and Thrombolytic Treatment: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines (8th Edition)
Chest, June 1, 2008; 133(6_suppl): 257S - 298S.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
S. T. Morozowich, B. S. Donahue, and I. J. Welsby
Genetics of coagulation: considerations for cardiac surgery.
Seminars in Cardiothoracic and Vascular Anesthesia, December 1, 2006; 10(4): 297 - 313.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. Hetzer, E. V. Potapov, B. Stiller, Y. Weng, M. Hubler, J. Lemmer, V. Alexi-Meskishvili, M. Redlin, F. Merkle, F. Kaufmann, et al.
Improvement in survival after mechanical circulatory support with pneumatic pulsatile ventricular assist devices in pediatric patients.
Ann. Thorac. Surg., September 1, 2006; 82(3): 917 - 924.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
E. V. Potapov and R. Hetzer
Impact of PlA Polymorphism of Platelet GP IIb/IIIa Receptors on Clinical Course During Long-Term LVAD Support is Independent of Type of LVAD.
Ann. Thorac. Surg., September 1, 2006; 82(3): 1167 - 1167.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
E.V. Potapov and R. Hetzer
More pumps--more questions
J. Thorac. Cardiovasc. Surg., July 1, 2006; 132(1): 210 - 210.
[Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
R. Poston, J. Gu, J. Manchio, A. Lee, J. Brown, J. Gammie, C. White, and B. P. Griffith
Platelet function tests predict bleeding and thrombotic events after off-pump coronary bypass grafting
Eur. J. Cardiothorac. Surg., April 1, 2005; 27(4): 584 - 591.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2004 by The Society of Thoracic Surgeons.