ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Walles, T.
Right arrow Articles by Mertsching, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Walles, T.
Right arrow Articles by Mertsching, H.
Related Collections
Right arrow Mechanical Circulatory Assistance

Ann Thorac Surg 2004;77:864-868
© 2004 The Society of Thoracic Surgeons


Original article: cardiovascular

Functional neointima characterization of vascular prostheses in human

Thorsten Walles, MDa*, Heidi Görler, MDb, Carmen Puschmann, PhDc, Heike Mertsching, PhDc

a Department of Thoracic and Vascular Surgery, Klinikum Hannover, Heidehaus, Hannover, Germany
b Division of Thoracic and Cardiovascular Surgery, Hannover Medical School, Hannover, Germany
c Leibniz Institute For Bioartificial Organs (LEBAO), Hannover, Germany

Accepted for publication August 15, 2003.

* Address reprint requests to Dr Walles, Thoracic and Vascular Surgery, Klinikum Hannover, Heidehaus, Am Leineufer 70, 30419 Hannover, Germany
e-mail: twalles{at}yahoo.com

BACKGROUND: The purpose of this study was to evaluate neointimal functionality of synthetic vascular grafts repopulated by host cells after implantation.

METHODS: We obtained reseeded inflow and outflow cannulas of 2 patients undergoing orthotopic heart transplantation after left ventricular assist device implantation 9 and 10 months before. After cell isolation we examined cellular function of reseeded cells and their capability to form a functional endothelial layer applying immunohistologic markers and quantitative Western blot for endothelial nitric oxide synthase activity.

RESULTS: Neointima formation in inflow and outflow cannulas differs macroscopically and by histologic appearance. The neointima formation on the surface of the polyethylene terephthalate fiber (Dacron) grafts differs substantially from native aortic vessel wall with respect to cellular and extracellular matrix composition and cellular function.

CONCLUSIONS: The neointima of Dacron prostheses is composed of cells with rudimentary physiologic endothelial function. We conclude that synthetic matrices are not suitable scaffolds for generating functional cardiovascular implants.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
Y. Tomizawa
Endothelialization and Functional Neointima on Vascular Grafts in Humans
Ann. Thorac. Surg., April 1, 2005; 79(4): 1465 - 1465.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Protopapas
Neointima in Vascular Prostheses: The Jury is Still Out
Ann. Thorac. Surg., April 1, 2005; 79(4): 1466 - 1466.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Walles and H. Mertsching
Endothelialization and Functional Neointima on Vascular Grafts in Humans: Reply
Ann. Thorac. Surg., April 1, 2005; 79(4): 1465 - 1466.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Walles, B. Giere, P. Macchiarini, and H. Mertsching
Expansion of chondrocytes in a three-dimensional matrix for tracheal tissue engineering
Ann. Thorac. Surg., August 1, 2004; 78(2): 444 - 448.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2004 by The Society of Thoracic Surgeons.