Ann Thorac Surg 2004;77:1110-1120
© 2004 The Society of Thoracic Surgeons
a Clinic for Cardiovascular Surgery, University Hospital, Berne, Switzerland
* Address reprint requests to Dr Carrel, Clinic for Cardiovascular Surgery, University Hospital Berne, CH-3010 Berne, Switzerland
e-mail: thierry.carrel{at}insel.ch
Recent developments in minimally invasive coronary artery surgery have been driven by the introduction of new technologies which should facilitate precise surgical maneuvers on the beating heart within confined spaces. Such technologies include coronary stabilizer systems, cardiac positioning vacuum-assisted devices, and telemanipulative systems. Despite these developments, standard suturing techniques using running polypropylene material remains a limiting factor in the surgeon's ability to perform complete revascularization with high quality anastomoses through minimal approaches to the chest cavity. Clinical validation of proximal and distal anastomotic devices has the potential to substantially improve and perhaps revolutionize minimally invasive coronary surgery. Ideal characteristics of such devices would include applicability to all conduit types, all coronary sizes, interchangeable proximal/distal sequencing of the anastomosis, and safe bail out for device malfunction. However there is an urgent need to define the performance objectives of such systems as well as the general criteria for proper and comparable evaluation and validation of different systems in animal models and subsequently in controlled prospective clinical studies. This review summarizes the most interesting systems available in both experimental and clinical settings.
This article has been cited by other articles:
![]() |
J. Kempfert, U. T. Opfermann, M. Richter, T. Bossert, F. W. Mohr, and J. F. Gummert Twelve-month patency with the PAS-port proximal connector device: a single center prospective randomized trial. Ann. Thorac. Surg., May 1, 2008; 85(5): 1579 - 1584. [Abstract] [Full Text] [PDF] |
||||
![]() |
W. J.L. Suyker and C. Borst Coronary connector devices: analysis of 1,469 anastomoses in 1,216 patients. Ann. Thorac. Surg., May 1, 2008; 85(5): 1828 - 1836. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Kappert, S.-M. Tugtekin, R. Cichon, M. Braun, and K. Matschke Robotic totally endoscopic coronary artery bypass: A word of caution implicated by a five-year follow-up. J. Thorac. Cardiovasc. Surg., April 1, 2008; 135(4): 857 - 862. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Ferrari, P. Tozzi, and L. K. von Segesser The Vascular Join: a new sutureless anastomotic device to perform end-to-end anastomosis. Preliminary results in an animal model Interactive CardioVascular and Thoracic Surgery, February 1, 2007; 6(1): 5 - 8. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Tozzi, E. Borghi, E. Haesler, G. Siniscalchi, A. Motti, D. Hayoz, and L. K. von Segesser Progress in cardiovascular anastomoses: will the vascular join replace Carrel's technique? Eur. J. Cardiothorac. Surg., September 1, 2006; 30(3): 425 - 430. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. F. Gummert, S. Demertzis, K. Matschke, U. Kappert, M. Anssar, F. Siclari, V. Falk, E. L. Alderman, and W. Harringer Six-Month Angiographic Follow-Up of the PAS-Port II Clinical Trial Ann. Thorac. Surg., January 1, 2006; 81(1): 90 - 96. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. S. F. Fischer, B. Phillips-Bute, M. Swaminathan, C. Milano, and M. Stafford-Smith SymmetryTM Aortic Connector Devices and Acute Renal Injury: A Comparison of Renal Dysfunction After Three Different Aortocoronary Bypass Surgery Techniques Anesth. Analg., January 1, 2006; 102(1): 25 - 31. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. E. Matschke, J. F. Gummert, S. Demertzis, U. Kappert, M. B. Anssar, F. Siclari, V. Falk, E. L. Alderman, C. Detter, H. Reichenspurner, et al. The Cardica C-Port System: Clinical and angiographic evaluation of a new device for automated, compliant distal anastomoses in coronary artery bypass grafting surgery--A multicenter prospective clinical trial J. Thorac. Cardiovasc. Surg., December 1, 2005; 130(6): 1645 - 1652. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Klima, T. Kofidis, A. Boening, and A. Haverich Long term angiographic monitoring reveals safety and efficacy of the Converge end-to-side anastomotic coupler Interactive CardioVascular and Thoracic Surgery, December 1, 2005; 4(6): 505 - 508. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Y. Loisance, K. Nakashima, and M. Kirsch Computer-assisted coronary surgery: lessons from an initial experience Interactive CardioVascular and Thoracic Surgery, October 1, 2005; 4(5): 398 - 401. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Akpinar, M. Guden, E. Sagbas, I. Sanisoglu, M. U. Ergenoglu, and C. Turkoglu Clinical experience with the Novare Enclose II manual proximal anastomotic device during off-pump coronary artery surgery Eur. J. Cardiothorac. Surg., June 1, 2005; 27(6): 1070 - 1073. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Boening, F. Schoeneich, A. Lichtenberg, E. Bagaev, J. T. Cremer, and U. Klima First clinical results with a 30{degrees} end-to-side coronary anastomosis coupler Eur. J. Cardiothorac. Surg., May 1, 2005; 27(5): 876 - 881. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |