ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Toshihiko Shibata
Koji Hattori
Shigefumi Suehiro
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Shibata, T.
Right arrow Articles by Suehiro, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Shibata, T.
Right arrow Articles by Suehiro, S.
Related Collections
Right arrow Extracorporeal circulation

Ann Thorac Surg 2004;77:220-225
© 2004 The Society of Thoracic Surgeons


Original article: cardiovascular

Sonoclot analysis in cardiac surgery in dialysis-dependent patients

Toshihiko Shibata, MD, PhDa*, Yasuyuki Sasaki, MD, PhDa, Koji Hattori, MD, PhDa, Hidekazu Hirai, MDa, Mitsuharu Hosono, MD, PhDa, Hiromichi Fujii, MD, PhDa, Shigefumi Suehiro, MD, PhDa

a Department of Cardiovascular Surgery, Osaka City University Medical School, Osaka, Japan

Accepted for publication August 1, 2003.

* Address reprint requests to Dr Shibata, Department of Cardiovascular Surgery, Osaka City University Medical School, 1-4-3, Asahi-machi, Abeno, Osaka 545-8585, Japan
e-mail: shibata{at}msic.med.osaka-cu.ac.jp

BACKGROUND: Dialysis-dependent patients have multiple disorders of hemostasis; however, there are no reports of viscoelastic changes during cardiac surgery in such patients.

METHODS: Hemostasis in dialysis-dependent patients during cardiac operations was evaluated. Thirty patients who underwent cardiopulmonary bypass (CPB) were studied: 6 with chronic renal failure undergoing dialysis (HD group), and 24 without hemodialysis. Blood samples were obtained at four points: before sternotomy, 30 and 90 minutes after the start of CPB, and after protamine administration.

RESULTS: Activated clotting time (ACT) measured with Sonoclot analyzer was significantly correlated with ACT measured traditionally (r = 0.92; p < 0.001; y = 36.1 + 0.95x). Values for ACT measured with Sonoclot analyzer as well as traditional ACT increased significantly during CPB. Values for ACT measured with Sonoclot analyzer in the HD group were significantly longer than those in the control group. Before CPB, both ACT measured with Sonoclot analyzer and traditional ACT in the HD group were significantly longer than those in the control group; however, there were no significant differences in ACT measured with Sonoclot analyzer between the groups after CPB. Clot rates and peak signal values were significantly decreased during CPB in both groups, and returned to preoperative values after protamine administration. There were no significant differences in clot rate and peak signal values between the two groups. There were no differences between the two groups in changes of time to peak. Platelet counts in the HD group were significantly higher (p < 0.05) than those in the control group. There were no differences in platelet counts after CPB between the two groups. Antithrombin III levels decreased below 50% during and after CPB. Antithrombin III in the HD group was significantly lower (p < 0.01) than those in the control group. A significant time-group interaction was observed in antithrombin III levels.

CONCLUSIONS: Sonoclot signatures in HD patients showed no significant differences in viscoelastic changes compared with non-HD patients.




This article has been cited by other articles:


Home page
PerfusionHome page
U. Schott, L. G. Nilsson, M. Broman, and M. Engstrom
Monitoring of low molecular weight heparin anticoagulation during haemodialysis with a Sonoclot Analyzer
Perfusion, July 1, 2010; 25(4): 191 - 196.
[Abstract] [PDF]


Home page
Anesth. Analg.Home page
K. A. Tanaka, F. Szlam, H. Y. Sun, T. Taketomi, and J. H. Levy
Thrombin Generation Assay and Viscoelastic Coagulation Monitors Demonstrate Differences in the Mode of Thrombin Inhibition Between Unfractionated Heparin and Bivalirudin