ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Haithcock, B. E.
Right arrow Articles by Sabbah, H. N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Haithcock, B. E.
Right arrow Articles by Sabbah, H. N.
Related Collections
Right arrow Mechanical Circulatory Assistance

Ann Thorac Surg 2004;77:158-163
© 2004 The Society of Thoracic Surgeons


Original article: cardiovascular

Hemodynamic unloading of the failing left ventricle using an arterial-to-arterial extracorporeal flow circuit

Benjamin E. Haithcock, MDa,b, Hideaki Morita, MDa,b, Nervin H. Fanous, MDa,b, George Suzuki, MDa,b, Hani N. Sabbah, PhDa,b*

a Division of Cardiovascular Medicine, Department of Medicine, Henry Ford Heart and Vascular Institute, Detroit, Michigan, USA
b Department of Surgery, Henry Ford Health System, Detroit, Michigan, USA

* Address reprint requests to Dr Sabbah, Cardiovascular Research, Henry Ford Hospital, 2799 West Grand Blvd, Detroit, MI 48202, USA.
e-mail: hsabbah1{at}hfhs.org

Presented at the Forty-ninth Annual Meeting of the Southern Thoracic Surgical Association, Miami Beach, FL, Nov 7–9, 2002.

BACKGROUND: We tested the hypothesis that creation of a constant-flow extracorporeal circuit between the proximal and distal aorta will unload the failing left ventricle.

METHODS: Studies were performed in 14 heart failure dogs produced by intracoronary microembolizations. An extracorporeal circuit incorporating a diagonal pump was placed between a femoral and a carotid artery, with flow directed to the carotid. Hemodynamic measurements were made with the pump delivering 0.25 L/min through the circuit for 4 hours (active group). Measurements obtained from 8 sham-operated heart failure dogs were used for comparison (control group). Heart rate, peak left ventricular systolic pressure, left ventricular end-diastolic pressure, end-diastolic volume, end-systolic volume, and ejection fraction were measured at baseline and at 30, 60, 120, and 240 minutes.

RESULTS: There were no differences in any of the hemodynamic values during the 4 hours of follow-up in the control group. In the active group, there was no effect on heart rate or peak systolic pressure, but reductions between baseline and 240 minutes were observed in left ventricular end-diastolic pressure (15 ± 1 vs 6 ± 1 mm Hg, p < 0.05), end-diastolic volume (61 ± 3 vs 50 ± 3 mL, p < 0.05), and end-systolic volume (44 ± 2 vs 32 ± 2 mL, p < 0.05), and an increase in ejection fraction (28 ± 2 vs 37% ± 2%, p < 0.05).

CONCLUSIONS: Acute use of this artery-to-artery extracorporeal system effectively unloads the failing left ventricle. The potential benefits of this approach on long-term myocardial recovery in heart failure require further investigation.




This article has been cited by other articles:


Home page
Circ Heart FailHome page
J. A. Dixon and F. G. Spinale
Large Animal Models of Heart Failure: A Critical Link in the Translation of Basic Science to Clinical Practice
Circ Heart Fail, May 1, 2009; 2(3): 262 - 271.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
L. W. Miller
Continuous Aortic Flow Augmentation: Not Enough MOMENTUM
Circulation, September 16, 2008; 118(12): 1223 - 1224.
[Full Text] [PDF]


Home page
CirculationHome page
B. Greenberg, B. Czerska, R. M. Delgado, R. Bourge, M. R. Zile, M. Silver, M. Klapholz, E. Haeusslein, M. R. Mehra, P. Mather, et al.
Effects of Continuous Aortic Flow Augmentation in Patients With Exacerbation of Heart Failure Inadequately Responsive to Medical Therapy: Results of the Multicenter Trial of the Orqis Medical Cancion System for the Enhanced Treatment of Heart Failure Unresponsive to Medical Therapy (MOMENTUM)
Circulation, September 16, 2008; 118(12): 1241 - 1249.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. A. Konstam, B. Czerska, M. Bohm, R. M. Oren, J. Sadowski, S. Khanal, W. T. Abraham, A. Wasler, J. B. Dahm, A. Gavazzi, et al.
Continuous Aortic Flow Augmentation: A Pilot Study of Hemodynamic and Renal Responses to a Novel Percutaneous Intervention in Decompensated Heart Failure
Circulation, November 15, 2005; 112(20): 3107 - 3114.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
D. Mancini and D. Burkhoff
Mechanical Device-Based Methods of Managing and Treating Heart Failure
Circulation, July 19, 2005; 112(3): 438 - 448.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2004 by The Society of Thoracic Surgeons.