ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gurevitch, J.
Right arrow Articles by Aravot, D. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gurevitch, J.
Right arrow Articles by Aravot, D. J.
Related Collections
Right arrow Coronary disease

Ann Thorac Surg 2003;76:1523-1527
© 2003 The Society of Thoracic Surgeons


Original article: cardiovascular

Noninvasive evaluation of arterial grafts with newly released multidetector computed tomography

Jacob Gurevitch, MDa*, Tamar Gaspar, MDb, Boris Orlov, MDa, Ron Amar, MDa, Dan Dvir, MDa, Nathan Peled, MDb, Dan J. Aravot, MDa

a Department of Thoracic and Cardiovascular Surgery, The Lady Davis Carmel Medical Center, affiliated to the Rappaport Faculty of Medicine, Technion-Haifa, Israel
b Department of Radiology, The Lady Davis Carmel Medical Center, affiliated with the Rappaport Faculty of Medicine, Technion-Haifa, Israel

Accepted for publication May 29, 2003.

* Address reprint requests to Dr Gurevitch, Department of Thoracic and Cardiovascular Surgery, Carmel Medical Center, 7 Michal St, Haifa, Israel.
e-mail: nettag{at}barak-online.net

Abstract

BACKGROUND: High-quality postoperative imaging of bypass conduits is essential when evaluating different types of conduits, anastomoses, and surgical techniques. We investigated the potential value of the newest generation of multidetector-row computer tomographic scanners in assessing bypass grafts.

METHODS: From June to September 2002, 14 patients underwent scanning with a newly released 16-slice computed tomographic scanner (Mx8000 IDT; Philips Medical Systems) after coronary artery bypass grafting. Four patients had had minimally invasive direct coronary artery bypass grafting and 3, redo coronary artery revascularization. Contrast-enhanced computed tomographic angiography was performed using retrospective electrocardiographic gating. Scan length was 22 to 30 cm, and total scan time was 27 to 37 seconds.

RESULTS: Of the 14 patients, 8 were scanned within 1 week after operation and 6, 1 month to 12 months postoperatively. Average heart rate during the scan was 82 beats per minute (range, 60 to 97 beats per minute), and all patients were able to hold their breath for the required time. Thirty conduits were studied: 26 arterial (18 in situ left and right internal mammary artery grafts, five free right internal mammary and radial artery grafts, and three in situ right gastroepiploic artery grafts) and four vein grafts. Excellent visualization of all 30 grafts was achieved. Thirty-four of the 35 distal anastomoses were patent; one vein graft was occluded.

CONCLUSIONS: This new technology is a promising noninvasive measure to evaluate patency of bypass conduits, including the gastroepiploic artery where catheterization is usually difficult. The ability to display the vessel wall as well as its lumen might distinguish radial artery spasm from intimal hyperplasia. The superb resolution and increased scan length required to cover the entire internal mammary artery grafts—from origin to distal anastomoses—can be achieved easily in a single breath-holding owing to the increased number of slices per rotation and shortening of the gantry rotation time.




This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
G. Muhlenbruch, A. H. Mahnken, M. Das, R. Blindt, C. Hohl, J. E. Wildberger, R. W. Gunther, H. P. Kuhl, and R. Koos
Evaluation of Aortocoronary Bypass Stents with Cardiac MDCT Compared with Conventional Catheter Angiography
Am. J. Roentgenol., February 1, 2007; 188(2): 361 - 369.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. M. Jones, T. Athanasiou, N. Dunne, J. Kirby, O. Aziz, A. Haq, C. Rao, V. Constantinides, S. Purkayastha, and A. Darzi
Multi-Detector Computed Tomography in Coronary Artery Bypass Graft Assessment: A Meta-Analysis
Ann. Thorac. Surg., January 1, 2007; 83(1): 341 - 348.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
M. J. Budoff, S. Achenbach, R. S. Blumenthal, J. J. Carr, J. G. Goldin, P. Greenland, A. D. Guerci, J. A.C. Lima, D. J. Rader, G. D. Rubin, et al.
Assessment of Coronary Artery Disease by Cardiac Computed Tomography: A Scientific Statement From the American Heart Association Committee on Cardiovascular Imaging and Intervention, Council on Cardiovascular Radiology and Intervention, and Committee on Cardiac Imaging, Council on Clinical Cardiology
Circulation, October 17, 2006; 114(16): 1761 - 1791.
[Full Text] [PDF]


Home page
Am. J. Roentgenol.Home page
H. Vernhet-Kovacsik, P. Battistella, R. Demaria, J. L. Pasquie, C. Bousquet, G. Dogas, F. Leclercq, B. Albat, and J. P. Senac
Early Postoperative Assessment of Coronary Artery Bypass Graft Patency and Anatomy: Value of Contrast-Enhanced 16-MDCT with Retrospectively ECG-Gated Reconstructions
Am. J. Roentgenol., June 1, 2006; 186(6_Supplement_2): S395 - S400.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Yamamoto, F. Kimura, H. Niinami, Y. Suda, E. Ueno, and Y. Takeuchi
Noninvasive Assessment of Off-Pump Coronary Artery Bypass Surgery by 16-Channel Multidetector-Row Computed Tomography.
Ann. Thorac. Surg., March 1, 2006; 81(3): 820 - 827.
[Abstract] [Full Text] [PDF]


Home page
RadioGraphicsHome page
A. A. Frazier, F. Qureshi, K. M. Read, R. C. Gilkeson, R. S. Poston, and C. S. White
Coronary Artery Bypass Grafts: Assessment with Multidetector CT in the Early and Late Postoperative Settings
RadioGraphics, July 1, 2005; 25(4): 881 - 896.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M.-H. Song, T. Ito, T. Watanabe, and H. Nakamura
Multidetector Computed Tomography Versus Coronary Angiogram in Evaluation of Coronary Artery Bypass Grafts
Ann. Thorac. Surg., February 1, 2005; 79(2): 585 - 588.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
E. Martuscelli, A. Romagnoli, A. D'Eliseo, M. Tomassini, C. Razzini, M. Sperandio, G. Simonetti, F. Romeo, and J.L. Mehta
Evaluation of Venous and Arterial Conduit Patency by 16-Slice Spiral Computed Tomography
Circulation, November 16, 2004; 110(20): 3234 - 3238.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2003 by The Society of Thoracic Surgeons.