|
|
||||||||
Ann Thorac Surg 2003;76:749-753
© 2003 The Society of Thoracic Surgeons
a Division of Cardiac Surgery, London Health Sciences CenterLondon, Ontario, Canada
b Department of Clinical Epidemiology and Biostatistics, University of Western Ontario, London, Ontario, Canada
c Department of Surgery, Cleveland Clinic Florida, Weston, Florida, USA
Accepted for publication April 3, 2003.
* Address reprint requests to Dr Novick, Division of Cardiac Surgery, London Health Sciences Center, University Campus, P.O. Box 5339, 339 Windermere Road, London, Ontario, Canada N6A 5A5
e-mail: rjnovick{at}uwo.ca
BACKGROUND: Recent articles have commented on the "learning curve" in robotic-assisted coronary artery bypass grafting. We systematically studied this phenomenon using standard statistical and cumulative sum (CUSUM) failure methods.
METHODS: Ninety patients underwent internal thoracic artery (ITA) takedown and an attempt at ITA to coronary bypass on the beating heart using the Zeus telerobotic system from September 1999 to December 2001. The rates of mortality and 11 predefined major complications were compared in five quintiles of 18 consecutive patients each and a CUSUM curve was generated for the entire cohort.
RESULTS: All patients but one underwent successful endoscopic ITA takedown. Thirteen patients had a totally endoscopic anastomosis, whereas in 61 a small mini-thoracotomy or mini-sternotomy was used. Sixteen patients (17.8%) were converted electively to a sternotomy: 11 patients underwent off-pump and 5 patients on-pump surgery. There were no deaths; 13 patients (14.4%) incurred one or more of the 11 major complication(s), including 5, 1, 2, 3, and 2 in each of the five quintiles (p = 0.39). Standard statistical analyses identified a significant decrease in operating room time (p < 0.0001), as well as a decrease in the incidence of an occluded graft or wrong vessel grafted from quintiles 1 to 5 (p = 0.03). On CUSUM analysis, the failure curve was steep for the first 18 to 20 patients, before moderating its slope for the remainder of the experience.
CONCLUSIONS: Robotic ITA to coronary bypass on the beating heart has a moderately steep learning curve, which is mitigated by further experience. CUSUM analysis complimented standard statistical methods in detecting a cluster of suboptimal results during the early experience with this procedure.
This article has been cited by other articles:
![]() |
L. Noyez Control charts, Cusum techniques and funnel plots. A review of methods for monitoring performance in healthcare Interactive CardioVascular and Thoracic Surgery, September 1, 2009; 9(3): 494 - 499. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. M. Holzhey, S. Jacobs, T. Walther, M. Mochalski, F. W. Mohr, and V. Falk Cumulative sum failure analysis for eight surgeons performing minimally invasive direct coronary artery bypass J. Thorac. Cardiovasc. Surg., September 1, 2007; 134(3): 663 - 669. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. J Biau, M. Resche-Rigon, G. Godiris-Petit, R. S Nizard, and R. Porcher Quality control of surgical and interventional procedures: a review of the CUSUM Qual. Saf. Health Care, June 1, 2007; 16(3): 203 - 207. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Novick, S. A. Fox, L. W. Stitt, T. L. Forbes, and S. Steiner Direct comparison of risk-adjusted and non-risk-adjusted CUSUM analyses of coronary artery bypass surgery outcomes. J. Thorac. Cardiovasc. Surg., August 1, 2006; 132(2): 386 - 391. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. DeRose Jr, S. K. Balaram, C. Ro, D. G. Swistel, V. Singh, J. R. Wilentz, G. J. Todd, and R. C. Ashton Mid-term results and patient perceptions of robotically-assisted coronary artery bypass grafting Interactive CardioVascular and Thoracic Surgery, October 1, 2005; 4(5): 406 - 411. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.W. R. Bolton and J. E. Connally Results of a phase one study on robotically assisted myocardial revascularization on the beating heart Ann. Thorac. Surg., July 1, 2004; 78(1): 154 - 158. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |