ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Kay-Hyun Park
Kwhanmien Kim
Young Tak Lee
Pyo Won Park
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Park, K.-H.
Right arrow Articles by Park, P. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Park, K.-H.
Right arrow Articles by Park, P. W.

Ann Thorac Surg 2003;75:1785-1790
© 2003 The Society of Thoracic Surgeons


Original article: cardiovascular

Ascending aorta replacement and local repair of tear site in type a aortic dissection with arch tear

Kay-Hyun Park, MDa*, Kiick Sung, MDa, Kwhanmien Kim, MDa, Tae-Gook Jun, MDa, Young Tak Lee, MDa, Pyo Won Park, MDa

a Department of Thoracic and Cardiovascular Surgery, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, South Korea

Accepted for publication January 16, 2003.

* Address reprint requests to Dr Kay-Hyun Park, Department of Thoracic and Cardiovascular Surgery, Samsung Medical Center, #50 Ilwon-Dong, Kangnam-Ku, Seoul South Korea 135-710.
e-mail: drkhpark{at}yahoo.co.kr

BACKGROUND: Transaortic repair of the tear was previously proposed as a compromise alternative to total arch replacement for acute type A aortic dissection with an arch tear. However, there are no data about long-term prognosis and radiologic findings after this procedure.

METHODS: We reviewed the postoperative course and computed tomographic findings of 13 patients who underwent replacement of the ascending aorta and transaortic repair of an arch tear for acute type A aortic dissection.

RESULTS: There were no early or late deaths during a mean follow-up period of 36.8 months. Computed tomographic follow-up showed complete thrombosis with or without later regression of the false lumen in the descending thoracic aorta in 9 patients (69.2%). Thrombosis of the false lumen usually occurred within 3 months postoperatively. Repair techniques incorporating the full thickness of the aortic wall in closure of the tear resulted in higher rate of success than approximation of the intima only (7 of 8 versus 2 of 5 patients, p < 0.05).

CONCLUSIONS: Transaortic repair of the arch tear with replacement of the ascending aorta can be an option in selected patients who have a small intimal tear in the aortic arch. This option would be more viable for less experienced surgeons who would hesitate to replace the total arch.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
M. Gorlitzer, G. Weiss, M. Thalmann, G. Mertikian, W. Wislocki, J. Meinhart, F. Waldenberger, and M. Grabenwoger
Combined Surgical and Endovascular Repair of Complex Aortic Pathologies With a New Hybrid Prosthesis
Ann. Thorac. Surg., December 1, 2007; 84(6): 1971 - 1976.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2003 by The Society of Thoracic Surgeons.